A diagnostic model for coronavirus disease 2019 (COVID-19) based on radiological semantic and clinical features: a multi-center study
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objectives: Rapid and accurate diagnosis of coronavirus disease 2019 (COVID-19) is critical during the epidemic. We aim to identify differences in CT imaging and clinical manifestations between pneumonia patients with and without COVID-19, and to develop and validate a diagnostic model for COVID-19 based on radiological semantic and clinical features alone. Methods: A consecutive cohort of 70 COVID-19 and 66 non-COVID-19 pneumonia patients were retrospectively recruited from five institutions. Patients were divided into primary (n = 98) and validation (n = 38) cohorts. The chi-square test, Student’s t test, and Kruskal-Wallis H test were performed, comparing 1745 lesions and 67 features in the two groups. Three models were constructed using radiological semantic and clinical features through multivariate logistic regression. Diagnostic efficacies of developed models were quantified by receiver operating characteristic curve. Clinical usage was evaluated by decision curve analysis and nomogram. Results: Eighteen radiological semantic features and seventeen clinical features were identified to be significantly different. Besides ground-glass opacities (p = 0.032) and consolidation (p = 0.001) in the lung periphery, the lesion size (1–3 cm) is also significant for the diagnosis of COVID-19 (p = 0.027). Lung score presents no significant difference (p = 0.417). Three diagnostic models achieved an area under the curve value as high as 0.986 (95% CI 0.966~1.000). The clinical and radiological semantic models provided a better diagnostic performance and more considerable net benefits. Conclusions: Based on CT imaging and clinical manifestations alone, the pneumonia patients with and without COVID-19 can be distinguished. A model composed of radiological semantic and clinical features has an excellent performance for the diagnosis of COVID-19. Key Points: • Based on CT imaging and clinical manifestations alone, the pneumonia patients with and without COVID-19 can be distinguished. • A diagnostic model for COVID-19 was developed and validated using radiological semantic and clinical features, which had an area under the curve value of 0.986 (95% CI 0.966~1.000) and 0.936 (95% CI 0.866~1.000) in the primary and validation cohorts, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radiological findings from 81 patients with COVID-19 pneumonia in Wuhan, China: a descriptive study
Shi, H., Han, X., Jiang, N., Cao, Y., Alwalid, O., Gu, J., Fan, Y., & Zheng, C. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30086-4 · Cited by 3,664
CT Imaging Features of 2019 Novel Coronavirus (2019-nCoV)
Chung, M., Bernheim, A., Mei, X., Zhang, N., Huang, M., Zeng, X., Cui, J., Xu, W., Yang, Y., Fayad, Z. A., et al. (2020) · Radiology · doi:10.1148/radiol.2020200230 · Cited by 2,751 · cited 1×
“was evaluated by scoring each lobe from 0 to 4 [7], corresponding to normal, 1~25% infection, 26~50% infection, 51~75% infection, and more than 75% infection, respectively.”
MethodSelf-citationXie, X., Zhong, Z., Zhao, W., Zheng, C., Wang, F., & Liu, J. (2020) · Radiology · doi:10.1148/radiol.2020200343 · Cited by 1,960 · cited 1×
“However, false-negative results caused by unstable specimen processing are relatively high in clinical practice, which has worsened the spread of the outbreak [15] [16] [17] [18] .”
Background
Cited by
Wynants, L., Van Calster, B., Bonten, M. M., Collins, G. S., Debray, T. P., De Vos, M., Haller, M. C., Heinze, G., Moons, K. G., Riley, R. D., et al. (2020) · doi:10.1101/2020.03.24.20041020 · Cited by 3,070
Roberts, M., Driggs, D., Thorpe, M., Gilbey, J., Yeung, M., Ursprung, S., Aviles-Rivero, A. I., Etmann, C., McCague, C., Beer, L., et al. (2021) · Nature Machine Intelligence · doi:10.1038/s42256-021-00307-0 · Cited by 1,044
Roberts, M. T., Driggs, D., Thorpe, M., Gilbey, J., Yeung, M., Ursprung, S., Avilés-Rivero, A. I., Etmann, C., McCague, C., Beer, L., et al. (2020) · Apollo (University of Cambridge) · doi:10.17863/cam.64000 · Cited by 895
Struyf, T., Deeks, J. J., Dinnes, J., Takwoingi, Y., Davenport, C., Leeflang, M. M., Spijker, R., Hooft, L., Emperador, D., Dittrich, S., et al. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013665 · Cited by 571
Thoracic imaging tests for the diagnosis of COVID-19
Islam, N., Ebrahimzadeh, S., Salameh, J.-P., Kazi, S., Fabiano, N., Treanor, L., Absi, M., Hallgrimson, Z., Leeflang, M. M., Hooft, L., et al. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013639.pub4 · Cited by 196
Metadata
- Authors
- Chen, X., Tang, Y., Mo, Y., Li, S., Lin, D., Yang, Z., Yang, Z., Sun, H., Qiu, J., Liao, Y., Xiao, J., Chen, X., Wu, X., Wu, R., & Dai, Z.
- Venue
- European Radiology
- Published
- 2020-04-16
- Volume
- 30
- Issue
- 9
- Pages
- 4893-4902
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W3016544281
- Cited by
- 129
- References
- 3
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.