CoChat

Any unique image biomarkers associated with COVID-19?

Open access
Pu, Jiantao, Leader, Joseph, Bandos, Andriy, Shi, Junli, Du, Pang, Yu, Juezhao, Yang, Bohan, Ke, Shi, Guo, Youmin, Field, Jessica B., Fuhrman, Carl, Wilson, David, Sciurba, Frank, Jin, Chenwang · 2020 · European Radiology
Cited by 45

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

To define the uniqueness of chest CT infiltrative features associated with COVID-19 image characteristics as potential diagnostic biomarkers. We retrospectively collected chest CT exams including n = 498 on 151 unique patients RT-PCR positive for COVID-19 and n = 497 unique patients with community-acquired pneumonia (CAP). Both COVID-19 and CAP image sets were partitioned into three groups for training, validation, and testing respectively. In an attempt to discriminate COVID-19 from CAP, we developed several classifiers based on three-dimensional (3D) convolutional neural networks (CNNs). We also asked two experienced radiologists to visually interpret the testing set and discriminate COVID-19 from CAP. The classification performance of the computer algorithms and the radiologists was assessed using the receiver operating characteristic (ROC) analysis, and the nonparametric approaches with multiplicity adjustments when necessary. One of the considered models showed non-trivial, but moderate diagnostic ability overall (AUC of 0.70 with 99% CI 0.56–0.85). This model allowed for the identification of 8–50% of CAP patients with only 2% of COVID-19 patients. Professional or automated interpretation of CT exams has a moderately low ability to distinguish between COVID-19 and CAP cases. However, the automated image analysis is promising for targeted decision-making due to being able to accurately identify a sizable subsect of non-COVID-19 cases. • Both human experts and artificial intelligent models were used to classify the CT scans. • ROC analysis and the nonparametric approaches were used to analyze the performance of the radiologists and computer algorithms. • Unique image features or patterns may not exist for reliably distinguishing all COVID-19 from CAP; however, there may be imaging markers that can identify a sizable subset of non-COVID-19 cases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00330-020-06956-w

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 45

Metadata

Authors
Pu, J., Leader, J., Bandos, A., Shi, J., Du, P., Yu, J., Yang, B., Ke, S., Guo, Y., Field, J. B., Fuhrman, C., Wilson, D., Sciurba, F., & Jin, C.
Venue
European Radiology
Published
2020-07-20
Volume
30
Issue
11
Pages
6221-6227
ISSN
  • 0938-7994 (ISSN-L)
  • 1432-1084
OpenAlex
W3032754356
Cited by
45
References
3
FWCI
4.03
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Any unique image biomarkers associated with COVID-19? https://app.cochat.ai/papers/10.1007/s00330-020-06956-w
The paper
Pu, J., Leader, J., Bandos, A., Shi, J., Du, P., Yu, J., Yang, B., Ke, S., Guo, Y., Field, J. B., Fuhrman, C., Wilson, D., Sciurba, F., & Jin, C. (2020). Any unique image biomarkers associated with COVID-19? European Radiology. https://doi.org/10.1007/s00330-020-06956-w

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.