The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Radiomics in predicting treatment response in non-small-cell lung cancer: current status, challenges and future perspectives
Open accessAbstract
Objectives: Radiomics is the extraction of quantitative data from medical imaging, which has the potential to characterise tumour phenotype. The radiomics approach has the capacity to construct predictive models for treatment response, essential for the pursuit of personalised medicine. In this literature review, we summarise the current status and evaluate the scientific and reporting quality of radiomics research in the prediction of treatment response in non-small-cell lung cancer (NSCLC). Methods: A comprehensive literature search was conducted using the PubMed database. A total of 178 articles were screened for eligibility and 14 peer-reviewed articles were included. The radiomics quality score (RQS), a radiomics-specific quality metric emulating the TRIPOD guidelines, was used to assess scientific and reporting quality. Results: Included studies reported several predictive markers including first-, second- and high-order features, such as kurtosis, grey-level uniformity and wavelet HLL mean respectively, as well as PET-based metabolic parameters. Quality assessment demonstrated a low median score of + 2.5 (range − 5 to + 9), mainly reflecting a lack of reproducibility and clinical evaluation. There was extensive heterogeneity between studies due to differences in patient population, cancer stage, treatment modality, follow-up timescales and radiomics workflow methodology. Conclusions: Radiomics research has not yet been translated into clinical use. Efforts towards standardisation and collaboration are needed to identify reproducible radiomic predictors of response. Promising radiomic models must be externally validated and their impact evaluated within the clinical pathway before they can be implemented as a clinical decision-making tool to facilitate personalised treatment for patients with NSCLC. Key Points: • The included studies reported several promising radiomic markers of treatment response in lung cancer; however, there was a lack of reproducibility between studies. • Quality assessment using the radiomics quality score (RQS) demonstrated a low median total score of + 2.5 (range − 5 to + 9). • Future radiomics research should focus on implementation of standardised radiomics features and software, together with external validation in a prospective setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1)
Eisenhauer, E. A., Therasse, P., Bogaerts, J., Schwartz, L. H., Sargent, D., Ford, R., Dancey, J., Arbuck, S., Gwyther, S., Mooney, M., et al. (2009) · European Journal of Cancer · doi:10.1016/j.ejca.2008.10.026 · Cited by 29,534 · cited 1×
“Response Evaluation Criteria in Solid Tumours (RECIST) provides an objective, standardised method for reporting response to therapy based on unidimensional evaluation of tumour size [6].”
MethodRadiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421
Radiomics: the bridge between medical imaging and personalized medicine
Lambin, P., Leijenaar, R. T. H., Deist, T. M., Peerlings, J., de Jong, E. E. C., van Timmeren, J., Sanduleanu, S., Larue, R. T. H. M., Even, A. J. G., Jochems, A., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.141 · Cited by 5,688
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177 · cited 1×
“The image biomarker standardisation initiative (IBSI) has attempted to address the lack of standardisation in radiomics by defining standardised imaging biomarker nomenclature and producing tools for verifying radiomics software implementations [35].”
Collins, G. S., Reitsma, J. B., Altman, D. G., & Moons, K. G. M. (2015) · British Journal of Cancer · doi:10.1038/bjc.2014.639 · Cited by 3,293
Collins, G. S., Reitsma, J. B., Altman, D. G., & Moons, K. G. M. (2015) · Annals of Internal Medicine · doi:10.7326/m14-0697 · Cited by 3,267
Repeatability and Reproducibility of Radiomic Features: A Systematic Review
Traverso, A., Wee, L., Dekker, A., & Gillies, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.053 · Cited by 903
Weber, W. A., Petersen, V., Schmidt, B., Tyndale-Hines, L., Link, T., Peschel, C., & Schwaiger, M. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.12.004 · Cited by 493
Cook, G. J. R., Yip, C., Siddique, M., Goh, V., Chicklore, S., Roy, A., Marsden, P., Ahmad, S., & Landau, D. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.107375 · Cited by 394
False Discovery Rates in PET and CT Studies with Texture Features: A Systematic Review
Chalkidou, A., O’Doherty, M. J., & Marsden, P. K. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124165 · Cited by 344
Radiomic phenotype features predict pathological response in non-small cell lung cancer
Coroller, T. P., Agrawal, V., Narayan, V., Hou, Y., Grossmann, P., Lee, S. W., Mak, R. H., & Aerts, H. J. W. L. (2016) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2016.04.004 · Cited by 327
From Handcrafted to Deep-Learning-Based Cancer Radiomics: Challenges and Opportunities
Afshar, P., Mohammadi, A., Plataniotis, K. N., Oikonomou, A., & Benali, H. (2019) · IEEE Signal Processing Magazine · doi:10.1109/msp.2019.2900993 · Cited by 294
Truhn, D., Schrading, S., Haarburger, C., Schneider, H., Merhof, D., & Kuhl, C. (2019) · Radiology · doi:10.1148/radiol.2018181352 · Cited by 273
Sollini, M., Antunovic, L., Chiti, A., & Kirienko, M. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04372-x · Cited by 250
Radiomic-Based Pathological Response Prediction from Primary Tumors and Lymph Nodes in NSCLC
Coroller, T. P., Agrawal, V., Huynh, E., Narayan, V., Lee, S. W., Mak, R. H., & Aerts, H. J. W. L. (2017) · Journal of Thoracic Oncology · doi:10.1016/j.jtho.2016.11.2226 · Cited by 228
Cook, G., O'Brien, M. E. R., Siddique, M., Chicklore, S., Loi, H. Y., Sharma, B., Punwani, R., Bassett, P., Goh, V., & Chua, S. C. (2015) · Radiology · doi:10.1148/radiol.2015141309 · Cited by 159
Ohno, Y., Koyama, H., Yoshikawa, T., Matsumoto, K., Aoyama, N., Onishi, Y., & Sugimura, K. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.6525 · Cited by 129
Ravanelli, M., Farina, D., Morassi, M., Roca, E., Cavalleri, G., Tassi, G., & Maroldi, R. (2013) · European Radiology · doi:10.1007/s00330-013-2965-0 · Cited by 122
Radiomics for Response and Outcome Assessment for Non-Small Cell Lung Cancer
Shi, L., He, Y., Yuan, Z., Benedict, S., Valicenti, R. K., Qiu, J., & Rong, Y. (2018) · Technology in Cancer Research & Treatment · doi:10.1177/1533033818782788 · Cited by 103
Aukema, T. S., Kappers, I., Olmos, R. A. V., Codrington, H., van Tinteren, H., van Pel, R., Klomp, H. M., & on behalf of the NEL Study Group (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.076224 · Cited by 81
Novel Quantitative Imaging for Predicting Response to Therapy: Techniques and Clinical Applications
Bera, K., Velcheti, V., & Madabhushi, A. (2018) · American Society of Clinical Oncology Educational Book · doi:10.1200/edbk_199747 · Cited by 75
Litière, S., Isaac, G., de Vries, E. G. E., Bogaerts, J., Chen, A. P., Dancey, J. E., Ford, R., Gwyther, S. J., Hoekstra, O. S., Huang, E. P., et al. (2019) · Journal of Clinical Oncology · doi:10.1200/jco.18.01100 · Cited by 74
A radiomic approach for adaptive radiotherapy in non-small cell lung cancer patients
Ramella, S., Fiore, M., Greco, C., Cordelli, E., Sicilia, R., Merone, M., Molfese, E., Miele, M., Cornacchione, P., Ippolito, E., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0207455 · Cited by 69
Chong, Y., Kim, J., Lee, H. Y., Ahn, Y. C., Lee, K. S., Ahn, M., Kim, J., Shim, Y. M., Han, J., & Choi, Y. (2014) · PLoS ONE · doi:10.1371/journal.pone.0088598 · Cited by 54
Mohammadi, A., Afshar, P., Asif, A. A., Farahani, K., Kirby, J., Oikonomou, A., & Plataniotis, K. N. (2018) · IEEE Signal Processing Magazine · doi:10.1109/msp.2018.2877123 · Cited by 42
Keam, B., Lee, S. J., Kim, T. M., Paeng, J. C., Lee, S., Kim, D., Jeon, Y. K., Chung, D. H., Kang, K. W., Chung, J.-K., et al. (2015) · Journal of Thoracic Oncology · doi:10.1097/jto.0000000000000569 · Cited by 29
NSCLC tumor shrinkage prediction using quantitative image features
Hunter, L. A., Chen, Y. P., Zhang, L., Matney, J. E., Choi, H., Kry, S. F., Martel, M. K., Stingo, F. C., Liao, Z. X., Gomez, D. R., et al. (2015) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2015.11.004 · Cited by 25
Radiologic-pathologic correlation of response to chemoradiation in resectable locally advanced NSCLC
Agrawal, V., Coroller, T. P., Hou, Y., Lee, S. W., Romano, J. L., Baldini, E. H., Chen, A. B., Jackman, D. M., Kozono, D., Swanson, S., et al. (2016) · Lung Cancer · doi:10.1016/j.lungcan.2016.10.002 · Cited by 24
The Long Route to Standardized Radiomics: Unraveling the Knot from the End
Kuhl, C. K., & Truhn, D. (2020) · Radiology · doi:10.1148/radiol.2020200059 · Cited by 21
Cited by
A review in radiomics: Making personalized medicine a reality via routine imaging
Guiot, J., Vaidyanathan, A., Deprez, L., Zerka, F., Danthine, D., Frix, A., Lambin, P., Bottari, F., Tsoutzidis, N., Miraglio, B., et al. (2022) · Medicinal Research Reviews · doi:10.1002/med.21846 · Cited by 337
Genova, C., Dellepiane, C., Carrega, P., Sommariva, S., Ferlazzo, G., Pronzato, P., Gangemi, R., Filaci, G., Coco, S., & Croce, M. (2022) · Frontiers in Immunology · doi:10.3389/fimmu.2021.799455 · Cited by 260
Understanding Sources of Variation to Improve the Reproducibility of Radiomics
Zhao, B. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.633176 · Cited by 158
Metadata
- Authors
- Chetan, M. R., & Gleeson, F. V.
- Venue
- European Radiology
- Published
- 2020-08-18
- Volume
- 31
- Issue
- 2
- Pages
- 1049-1058
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W3064574647
- Cited by
- 265
- References
- 29
- FWCI
- 18.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.