A comparison between manual and artificial intelligence–based automatic positioning in CT imaging for COVID-19 patients
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objective: To analyze and compare the imaging workflow, radiation dose, and image quality for COVID-19 patients examined using either the conventional manual positioning (MP) method or an AI-based automatic positioning (AP) method. Materials and methods: One hundred twenty-seven adult COVID-19 patients underwent chest CT scans on a CT scanner using the same scan protocol except with the manual positioning (MP group) for the initial scan and an AI-based automatic positioning method (AP group) for the follow-up scan. Radiation dose, patient positioning time, and off-center distance of the two groups were recorded and compared. Image noise and signal-to-noise ratio (SNR) were assessed by three experienced radiologists and were compared between the two groups. Results: The AP operation was successful for all patients in the AP group and reduced the total positioning time by 28% compared with the MP group. Compared with the MP group, the AP group had significantly less patient off-center distance (AP 1.56 cm ± 0.83 vs. MP 4.05 cm ± 2.40, p < 0.001) and higher proportion of positioning accuracy (AP 99% vs. MP 92%), resulting in 16% radiation dose reduction (AP 6.1 mSv ± 1.3 vs. MP 7.3 mSv ± 1.2, p < 0.001) and 9% image noise reduction in erector spinae and lower noise and higher SNR for lesions in the pulmonary peripheral areas. Conclusion: The AI-based automatic positioning and centering in CT imaging is a promising new technique for reducing radiation dose and optimizing imaging workflow and image quality in imaging the chest. Key Points: • The AI-based automatic positioning (AP) operation was successful for all patients in our study. • AP method reduced the total positioning time by 28% compared with the manual positioning (MP). • AP method had less patient off-center distance and higher proportion of positioning accuracy than MP method, resulting in 16% radiation dose reduction and 9% image noise reduction in erector spinae.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CT Imaging Features of 2019 Novel Coronavirus (2019-nCoV)
Chung, M., Bernheim, A., Mei, X., Zhang, N., Huang, M., Zeng, X., Cui, J., Xu, W., Yang, Y., Fayad, Z. A., et al. (2020) · Radiology · doi:10.1148/radiol.2020200230 · Cited by 2,751
Shi, F., Wang, J., Shi, J., Wu, Z., Wang, Q., Tang, Z., He, K., Shi, Y., & Shen, D. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2987975 · Cited by 1,404 · cited 1×
“The combination of AI and CT imaging can provide faster, more accurate, and efficient imaging-based diagnosis [5].”
Background
Cited by
Artificial intelligence in healthcare delivery: Prospects and pitfalls
Olawade, D. B., David-Olawade, A. C., Wada, O. Z., Asaolu, A. J., Adereni, T., & Ling, J. (2024) · Journal of Medicine, Surgery, and Public Health · doi:10.1016/j.glmedi.2024.100108 · Cited by 180
Pierre, K., Haneberg, A. G., Kwak, S., Peters, K. R., Hochhegger, B., Sananmuang, T., Tunlayadechanont, P., Tighe, P. J., Mancuso, A., & Forghani, R. (2023) · Seminars in Roentgenology · doi:10.1053/j.ro.2023.02.003 · Cited by 79
Hanneman, K., Playford, D., Dey, D., van Assen, M., Mastrodicasa, D., Cook, T. S., Gichoya, J. W., Williamson, E. E., Rubin, G. D., & on behalf of the American Heart Association Council on Cardiovascular Radiology and Intervention; and Council on Lifelong Congenital Heart Disease and Heart Health in the Young (2024) · Circulation · doi:10.1161/cir.0000000000001202 · Cited by 72
“17 In MRI, AI tools can detect and mitigate motion artifacts to improve image quality 18 ; accelerate acquisitions, leading to overall shorter examination times 19 ; and automate contouring for evaluation of ventricular volumes and ejection fraction.”
MethodMastrodicasa, D., van Assen, M., Huisman, M., Leiner, T., Williamson, E. E., Nicol, E. D., Allen, B. D., Saba, L., Vliegenthart, R., & Hanneman, K. (2025) · Radiology · doi:10.1148/radiol.240516 · Cited by 69
Artificial Intelligence in Emergency Radiology: Where Are We Going?
Cellina, M., Cè, M., Irmici, G., Ascenti, V., Caloro, E., Bianchi, L., Pellegrino, G., D’Amico, N., Papa, S., & Carrafiello, G. (2022) · Diagnostics · doi:10.3390/diagnostics12123223 · Cited by 62
“utilizing automated positioning, demonstrated a decrease of 16% in the dosage supplied to the patient, with a saving of 28% of the time [18].”
Method
Metadata
- Authors
- Gang, Y., Chen, X., Li, H., Wang, H., Li, J., Guo, Y., Zeng, J., Hu, Q., Hu, J., & Xu, H.
- Venue
- European Radiology
- Published
- 2021-03-19
- Volume
- 31
- Issue
- 8
- Pages
- 6049-6058
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W3117760845
- Cited by
- 63
- References
- 2
- FWCI
- 4.37
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.