Comparative analysis of GPT-4-based ChatGPT’s diagnostic performance with radiologists using real-world radiology reports of brain tumors
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Objectives: Large language models like GPT-4 have demonstrated potential for diagnosis in radiology. Previous studies investigating this potential primarily utilized quizzes from academic journals. This study aimed to assess the diagnostic capabilities of GPT-4-based Chat Generative Pre-trained Transformer (ChatGPT) using actual clinical radiology reports of brain tumors and compare its performance with that of neuroradiologists and general radiologists. Methods: We collected brain MRI reports written in Japanese from preoperative brain tumor patients at two institutions from January 2017 to December 2021. The MRI reports were translated into English by radiologists. GPT-4 and five radiologists were presented with the same textual findings from the reports and asked to suggest differential and final diagnoses. The pathological diagnosis of the excised tumor served as the ground truth. McNemar’s test and Fisher’s exact test were used for statistical analysis. Results: In a study analyzing 150 radiological reports, GPT-4 achieved a final diagnostic accuracy of 73%, while radiologists’ accuracy ranged from 65 to 79%. GPT-4’s final diagnostic accuracy using reports from neuroradiologists was higher at 80%, compared to 60% using those from general radiologists. In the realm of differential diagnoses, GPT-4’s accuracy was 94%, while radiologists’ fell between 73 and 89%. Notably, for these differential diagnoses, GPT-4’s accuracy remained consistent whether reports were from neuroradiologists or general radiologists. Conclusion: GPT-4 exhibited good diagnostic capability, comparable to neuroradiologists in differentiating brain tumors from MRI reports. GPT-4 can be a second opinion for neuroradiologists on final diagnoses and a guidance tool for general radiologists and residents. Clinical relevance statement: This study evaluated GPT-4-based ChatGPT’s diagnostic capabilities using real-world clinical MRI reports from brain tumor cases, revealing that its accuracy in interpreting brain tumors from MRI findings is competitive with radiologists. Key Points: We investigated the diagnostic accuracy of GPT-4 using real-world clinical MRI reports of brain tumors. GPT-4 achieved final and differential diagnostic accuracy that is comparable with neuroradiologists. GPT-4 has the potential to improve the diagnostic process in clinical radiology. Graphical Abstract:
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Language Models are Few-Shot Learners
Brown, T. B., Mann, B., Ryder, N., Subbiah, M., Kaplan, J., Dhariwal, P., Neelakantan, A., Shyam, P., Sastry, G., Askell, A., et al. (2020) · arXiv · doi:10.48550/arxiv.2005.14165 · Cited by 23,372
GPTs are GPTs: An Early Look at the Labor Market Impact Potential of Large Language Models
Eloundou, T., Manning, S., Mishkin, P., & Rock, D. (2023) · arXiv · doi:10.48550/arxiv.2303.10130 · Cited by 2,330
Sparks of Artificial General Intelligence: Early experiments with GPT-4
Bubeck, S., Chandrasekaran, V., Eldan, R., Gehrke, J., Horvitz, E., Kamar, E., Lee, P., Lee, Y. T., Li, Y., Lundberg, S., et al. (2023) · arXiv · doi:10.48550/arxiv.2303.12712 · Cited by 1,526
Fairness of artificial intelligence in healthcare: review and recommendations
Ueda, D., Kakinuma, T., Fujita, S., Kamagata, K., Fushimi, Y., Ito, R., Matsui, Y., Nozaki, T., Nakaura, T., Fujima, N., et al. (2024) · Japanese Journal of Radiology · doi:10.1007/s11604-023-01474-3 · Cited by 607
Self-citationBhayana, R., Krishna, S., & Bleakney, R. R. (2023) · Radiology · doi:10.1148/radiol.230582 · Cited by 460
Evaluating ChatGPT as an Adjunct for Radiologic Decision-Making
Rao, A., Kim, J., Kamineni, M., Pang, M., Lie, W., & Succi, M. D. (2023) · doi:10.1101/2023.02.02.23285399 · Cited by 257
Appropriateness of breast cancer prevention and screening recommendations provided by ChatGPT
Haver, H. L., Ambinder, E. B., Bahl, M., Oluyemi, E. T., Jeudy, J., & Yi, P. H. (2023) · Radiology · doi:10.1148/radiol.230424 · Cited by 247
A comparison of ChatGPT-generated articles with human-written articles
Ariyaratne, S., Iyengar, K. P., Nischal, N., Chitti Babu, N., & Botchu, R. (2023) · Skeletal Radiology · doi:10.1007/s00256-023-04340-5 · Cited by 148
Li, H., Moon, J. T., Iyer, D., Balthazar, P., Krupinski, E. A., Bercu, Z. L., Newsome, J. M., Banerjee, I., Gichoya, J. W., & Trivedi, H. M. (2023) · Clinical Imaging · doi:10.1016/j.clinimag.2023.06.008 · Cited by 118
Evaluating GPT-4-based ChatGPT’s Clinical Potential on the NEJM Quiz
Ueda, D., Walston, S. L., Matsumoto, T., Deguchi, R., Tatekawa, H., & Miki, Y. (2023) · doi:10.1101/2023.05.04.23289493 · Cited by 45
Self-citation
Cited by
Takita, H., Kabata, D., Walston, S. L., Tatekawa, H., Saito, K., Tsujimoto, Y., Miki, Y., & Ueda, D. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01543-z · Cited by 203
Self-citationShan, G., Chen, X., Wang, C., Liu, L., Gu, Y., Jiang, H., & Shi, T. (2025) · JMIR Medical Informatics · doi:10.2196/64963 · Cited by 71
de Almeida, J. G., Messiou, C., Withey, S. J., Matos, C., Koh, D.-M., & Papanikolaou, N. (2025) · European Radiology · doi:10.1007/s00330-025-11654-6 · Cited by 23
Tzanis, E., Adams, L. C., Akinci D’Antonoli, T., Bressem, K. K., Cuocolo, R., Kocak, B., Malamateniou, C., & Klontzas, M. E. (2026) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2025.10.002 · Cited by 16
Metadata
- Authors
- Mitsuyama, Y., Tatekawa, H., Takita, H., Sasaki, F., Tashiro, A., Oue, S., Walston, S. L., Nonomiya, Y., Shintani, A., Miki, Y., & Ueda, D.
- Venue
- European Radiology
- Published
- 2024-08-28
- Volume
- 35
- Issue
- 4
- Pages
- 1938-1947
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W4401944641
- Cited by
- 62
- References
- 10
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.