Cavity-enhanced optical frequency comb spectroscopy in the mid-infrared application to trace detection of hydrogen peroxide
Open accessThe DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Abstract
We demonstrate the first cavity-enhanced optical frequency comb spectroscopy in the mid-infrared wavelength region and report the sensitive real-time trace detection of hydrogen peroxide in the presence of a large amount of water. The experimental apparatus is based on a mid-infrared optical parametric oscillator synchronously pumped by a high-power Yb:fiber laser, a high-finesse broadband cavity, and a fast-scanning Fourier transform spectrometer with autobalancing detection. The comb spectrum with a bandwidth of 200 nm centered around 3.76 μm is simultaneously coupled to the cavity and both degrees of freedom of the comb, i.e. the repetition rate and carrier envelope offset frequency, are locked to the cavity to ensure stable transmission. The autobalancing detection scheme reduces the intensity noise by a factor of 300, and a sensitivity of 5.4×10−9 cm−1 Hz−1/2 with a resolution of 800 MHz is achieved (corresponding to 6.9×10−11 cm−1 Hz−1/2 per spectral element for 6000 resolved elements). This yields a noise equivalent detection limit for hydrogen peroxide of 8 parts-per-billion (ppb); in the presence of 2.8 % of water the detection limit is 130 ppb. Spectra of acetylene, methane, and nitrous oxide at atmospheric pressure are also presented, and a line-shape model is developed to simulate the experimental data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser phase and frequency stabilization using an optical resonator
Drever, R. W. P., Hall, J. L., Kowalski, F. V., Hough, J., Ford, G. M., Munley, A. J., & Ward, H. (1983) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00702605 · Cited by 3,811
The HITRAN 2008 molecular spectroscopic database
Rothman, L. S., Gordon, I. E., Barbe, A., Benner, D. C., Bernath, P. F., Birk, M., Boudon, V., Brown, L. R., Campargue, A., Champion, J.-P., et al. (2009) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2009.02.013 · Cited by 3,335
Fourier Transform Infrared Spectrometry
Griffiths, P. R., & de Haseth, J. A. (2007) · doi:10.1002/047010631x · Cited by 3,052
Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources
O’Keefe, A., & Deacon, D. A. G. (1988) · Review of Scientific Instruments · doi:10.1063/1.1139895 · Cited by 1,741
Colloquium: Femtosecond optical frequency combs
Cundiff, S. T., & Ye, J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.325 · Cited by 1,083
Self-citationGas-Phase Databases for Quantitative Infrared Spectroscopy
Sharpe, S. W., Johnson, T. J., Sams, R. L., Chu, P. M., Rhoderick, G. C., & Johnson, P. A. (2004) · Applied Spectroscopy · doi:10.1366/0003702042641281 · Cited by 948
Frequency-modulation spectroscopy: a new method for measuring weak absorptions and dispersions
Bjorklund, G. C. (1980) · Optics Letters · doi:10.1364/ol.5.000015 · Cited by 876
Exhaled Markers of Pulmonary Disease
KHARITONOV, S. A., & BARNES, P. J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2009041 · Cited by 844
Coherent Multiheterodyne Spectroscopy Using Stabilized Optical Frequency Combs
Coddington, I., Swann, W., & Newbury, N. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.013902 · Cited by 821
Molecular fingerprinting with the resolved modes of a femtosecond laser frequency comb
Diddams, S. A., Hollberg, L., & Mbele, V. (2007) · Nature · doi:10.1038/nature05524 · Cited by 805
Cited by
Schliesser, A., Picqué, N., & Hänsch, T. W. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.142 · Cited by 1,436
High-power sub-two-cycle mid-infrared pulses at 100 MHz repetition rate
Pupeza, I., Sánchez, D., Zhang, J., Lilienfein, N., Seidel, M., Karpowicz, N., Paasch-Colberg, T., Znakovskaya, I., Pescher, M., Schweinberger, W., et al. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.179 · Cited by 304
High-performance near- and mid-infrared crystalline coatings
Cole, G. D., Zhang, W., Bjork, B. J., Follman, D., Heu, P., Deutsch, C., Sonderhouse, L., Robinson, J., Franz, C., Alexandrovski, A., et al. (2016) · Optica · doi:10.1364/optica.3.000647 · Cited by 179
“To reach high detection sensitivity, a frequency comb (exhibiting a roughly 100 nm spectral bandwidth) is injected into a high-finesse optical cavity to create approximately 100,000 simultaneous cavity-enhanced detection modes [30,31].”
BackgroundMethodInfluentialSelf-citationDu, Z., Zhang, S., Li, J., Gao, N., & Tong, K. (2019) · Applied Sciences · doi:10.3390/app9020338 · Cited by 174
Self-corrected chip-based dual-comb spectrometer
Hébert, N. B., Genest, J., Deschênes, J.-D., Bergeron, H., Chen, G. Y., Khurmi, C., & Lancaster, D. G. (2017) · Optics Express · doi:10.1364/oe.25.008168 · Cited by 122
Metadata
- Authors
- Foltynowicz, A., Masłowski, P., Fleisher, A. J., Bjork, B. J., & Ye, J.
- Venue
- Applied Physics B
- Published
- 2012-05-01
- Volume
- 110
- Issue
- 2
- Pages
- 163-175
- ISSN
- 0721-7269 (ISSN-L)
- 0946-2171
- 1432-0649
- OpenAlex
- W2098825766
- Cited by
- 168
- References
- 69
- FWCI
- 4.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.