Veränderungen bei Depression, Angst und vitaler Erschöpfung bei Patienten nach einer ICD-Implantation: Vergleich klinischer Subgruppen

Tavenaux, M., Ginzburg, D.M., Boukacem, A., Sperzel, J., Hamm, C., Jordan, J. · 2011 · Herzschrittmachertherapie + Elektrophysiologie

The DOI matches its Crossref record; 18 of the 19 references it cites were found in a registry or an index.

Abstract

Background. The psychological strain of an implantable cardioverter- defibrillator (ICD) is infrequently explored in prospective studies, which have until now generally focused on the dimensions anxiety and depression. Furthermore, vital exhaustion (VE; ICD10 F 48.0) is known as a very good predictor for negative outcome in patients with coronary heart disease. The influence of VE on patients with an ICD is presented and analyzed in a prospective study. Methods. A total of 249 patients with an ICD completed a set of questionnaires (HADS, EQ-5D, VE) at baseline and at the 1-year follow-up. Results. The patients with high levels of depression, anxiety, and VE after ICD implantation did not show spontaneous remission after 1 year. Discussion. As expected, the implanatation of an ICD is associated with high acceptance and increased life quality in about 3/4 of patients. However, there is a subgroup of patients (20-30%) who have difficulties and the measured dimensions remain at elevated levels after implantation, thus, indicating that these patients probably need competent psychological help. © Springer-Verlag 2011.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00399-011-0144-z

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 18 references

Cited by

See all 2

Metadata

Authors
Tavenaux, M., Ginzburg, D. M., Boukacem, A., Sperzel, J., Hamm, C., & Jordan, J.
Affiliations
Kerckhoff Klinik (DE)
Venue
Herzschrittmachertherapie + Elektrophysiologie
Published
2011-07-21
Volume
22
Issue
3
Pages
174-180
ISSN
  • 0938-7412 (ISSN-L)
  • 1435-1544
OpenAlex
W167276229
Cited by
2
References
19
Citations by year
2013: 1
FWCI
0.44
Type
journal article
Language
de
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Herzschrittmachertherapie + Elektrophysiologie (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Oncology › Cancer survivorship and care
Keywords
implantable cardioverter-defibrillator, depression, anxiety, vital exhaustion, psychological strain, quality of life, coronary artery disease, psychological support, long-term follow-up
MeSH terms
Adaptation, Psychological, Aged, Anxiety Disorders, Attitude to Health, Cooperative Behavior, Coronary Disease, Depressive Disorder, Fatigue, Female, Follow-Up Studies, Heart Arrest, Humans, Male, Middle Aged, Patient Care Team, Prognosis, Prospective Studies, Psychotherapy, Quality of Life, Surveys and Questionnaires, Cohort Studies, Qi, Interdisciplinary Communication

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Veränderungen bei Depression, Angst und vitaler Erschöpfung bei Patienten nach einer ICD-Implantation: Vergleich klinischer Subgruppen. https://app.cochat.ai/papers/10.1007/s00399-011-0144-z
The paper
Tavenaux, M., Ginzburg, D. M., Boukacem, A., Sperzel, J., Hamm, C., & Jordan, J. (2011). Veränderungen bei Depression, Angst und vitaler Erschöpfung bei Patienten nach einer ICD-Implantation: Vergleich klinischer Subgruppen. Herzschrittmachertherapie + Elektrophysiologie. https://doi.org/10.1007/s00399-011-0144-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.