Precision of computer-assisted core decompression drilling of the femoral head
Abstract
Introduction Osteonecrosis of the femoral head is a local destructive disease with progression into devastating stages. Left untreated it mostly leads to severe secondary osteoarthrosis and early endoprosthetic joint replacement. Core decompression by exact drilling into the ischemic areas can be performed in early stages according to Ficat or ARCO. Computer-aided surgery might enhance the precision of the drilling and lower the radiation exposure time of both staff and patients. The aim of this study was to evaluate the precision of the fluoroscopically based VectorVision navigation system in an in vitro model. Materials and methods Thirty sawbones were prepared with a defect filled up with a radiopaque gypsum sphere mimicking the osteonecrosis. Twenty sawbones were drilled by guidance of an intraoperative navigation system VectorVision (BrainLAB, Munich, Germany) and 10 sawbones by fluoroscopic control only. Results No gypsum sphere was missed. There was a statistically significant difference regarding the three-dimensional deviation (Euclidian norm) as well as maximum deviation in x-, y- or z-direction (maximum norm) to the desired mid-point of the lesion, with a mean of 0.51 and 0.4 mm in the navigated group and 1.1 and 0.88 mm in the control group, respectively. Furthermore, significant difference was found in the number of drilling corrections as well as the radiation time needed: no second drilling or correction of drilling direction was necessary in the navigated grou…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
During core decompression surgery, the precision of drilling is essential to accurately decompress targeted lesions while avoiding femoral cartilage damage.
“During the surgery, the precision of the drilling is essential to accurately decompress the targeted lesions while avoiding any femoral cartilage damage (Beckmann et al. 2006).”
From Towards 2D/3D Registration of the Preoperative MRI to Intraoperative Fluoroscopic Images for Visualisation of Bone Defects (2023) · cites this paper as Beckmann et al. 2006
Core decompression requires acquisition of multiple intraoperative radiographs, which increases the risk of surgical complications and increases radiation exposure for both the patient and the surgical team.
“Core decompression procedure requires the acquisition of multiple intraoperative radiographs, which increases the risk of surgical complications and increases the radiation exposure for both the patient and the surgical team (Beckmann et al. 2006; Wang et al. 2017).”
From Towards 2D/3D Registration of the Preoperative MRI to Intraoperative Fluoroscopic Images for Visualisation of Bone Defects (2023) · cites this paper as Beckmann et al. 2006
Cited by
Sorted by citations
Patient-specific core decompression surgery for early-stage ischemic necrosis of the femoral head
Wang, W., Hu, W., Yang, P., Dang, X. Q., Li, X. H., & Wang, K. Z. (2017) · PLOS ONE · doi:10.1371/journal.pone.0175366 · Cited by 14 · see citing works
Ku, P.-C., Martin-Gomez, A., Gao, C., Grupp, R., Mears, S. C., & Armand, M. (2023) · Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization · doi:10.1080/21681163.2022.2152375 · Cited by 8 · see citing works
“Core decompression procedure requires the acquisition of multiple intraoperative radiographs, which increases the risk of surgical complications and increases the radiation exposure for both the patient and the surgical team (Beckmann et al. 2006; Wang et al. 2017).”
Background
- Authors
- Beckmann, J., Goetz, J., Baethis, H., Kalteis, T., Grifka, J., & Perlick, L.
- Affiliations
- Asklepios Kliniken Bad Abbach (DE)
- Corresponding author
- Beckmann, J.
- Venue
- Archives of Orthopaedic and Trauma Surgery
- Published
- 2006-06-01
- Volume
- 126
- Issue
- 6
- Pages
- 374-379
- ISSN
- 0936-8051 (ISSN-L)
- 1434-3916
- OpenAlex
- W2089295611
- Cited by
- 27
- References
- 0
- Citations by year
- 2025: 1 · 2023: 1 · 2022: 1 · 2021: 3 · 2020: 3 · 2019: 2 · 2018: 1 · 2017: 1 · 2016: 1 · 2013: 1
- FWCI
- 3.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Archives of Orthopaedic and Trauma Surgery (publishedVersion)
- PubMed (publishedVersion)
- University of Regensburg Publication Server (University of Regensburg) (acceptedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone and Joint Diseases
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Health Sciences › Medicine › Surgery › Hip disorders and treatments
- Keywords
- core decompression, osteonecrosis of the femoral head, computer-assisted surgery, surgical navigation, fluoroscopy, radiation dose reduction, in vitro model
- MeSH terms
- Femur Head, Fluoroscopy, Humans, Models, Anatomic, Osteonecrosis, Decompression, Surgical, Surgery, Computer-Assisted
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review