Cited by 84Tissue Engineering and Regenerative MedicineTendon Structure and TreatmentKnee injuries and reconstruction techniques

Tissue engineering of the anterior cruciate ligament: a new method using acellularized tendon allografts and autologous fibroblasts

Tischer, Thomas, Vogt, Stephan, Aryee, Sebastian, Steinhauser, Erwin, Adamczyk, Christopher, Milz, Stefan, Martinek, Vladimir, Imhoff, Andreas B.·2007·Archives of Orthopaedic and Trauma Surgery

Abstract

Introduction The availability of autogenous tendons (middle part of patellar tendon, semitendinosus/gracilis, or quadriceps tendon) for cruciate ligament reconstructions is restricted and related to withdrawal morbidity. Allografts and synthetic ligament materials often show problems regarding long-term stability and immunological reactions. Therefore, the aim of this study was to develop and characterize a new scaffold based on acellular allografts seeded with autologous cells for tissue engineering of the anterior cruciate ligament (ACL). Materials and methods Semitendinosus tendons of New Zealand White (NZW) rabbits were harvested and acellularized using the detergent sodium dodecyle sulfate (SDS) as the main ingredient. After that, cultured (37 degrees C, 5% CO(2), medium) dermal fibroblasts were injected into the tendons. These constructs were further cultivated for 4, 7, or 14 days under the same culture conditions. Native, acellular, and seeded tendons underwent biomechanical testing (ultimate load to failure [N], stiffness [N/mm], and elongation [%], each n = 9] and histological hematoxylin-eosin (H.E.) staining. Detailed immunohistochemical (collagen I, III, IV, VI, pro-collagen I, versican, and vimentin) analyses were conducted to detect changes in the composition and structure of the extracellular matrix (ECM) after acellularization. Results Histologically, a cell-free, crimped slack tendon structure after acellularization and a good integration of the cells after injection (4, 7, and 14 days) were seen. Metabolic activity of the seeded cells was demonstrated by positive immunohistochemical staining for pro-collagen I, which was negative in nonseeded constructs. Major differences in staining patterns of the various other ECM components were not observed. Biomechanically, the maximum load to failure of these tendons was comparable to native tendons (P = 0.429; native 134.5 +/- 12.9 N; acellular 118.5 +/- 7.3 N; seeded 132.3 +/- 5.6 N). Stiffness and elongation were comparable between native and acellular tendons, but differed significantly after seeding (P < 0.001). Conclusion The described method is suitable to make tendons completely cell free without changing their major biomechanical properties. Preservation of the ECM and of the collagen fiber structure by this method should give an ideal environment for autologous cell integration and metabolic activity in contrast to other approaches for tissue acellularization. The cell disruption and extraction of cell detritus should minimize adverse immunogenic reactions.

Integrity signals

Registry

Crossref · 10.1007/s00402-007-0320-0

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Authors
Tischer, T., Vogt, S., Aryee, S., Steinhauser, E., Adamczyk, C., Milz, S., Martinek, V., & Imhoff, A. B.
Affiliations
  • Technical University of Munich (DE)
  • Ludwig-Maximilians-Universität München (DE)
  • AO Foundation (CH)
  • University of Rostock (DE)
Corresponding author
Tischer, Thomas
Venue
Archives of Orthopaedic and Trauma Surgery
Published
2007-05-31
Volume
127
Issue
9
Pages
735-741
ISSN
  • 0936-8051 (ISSN-L)
  • 1434-3916
OpenAlex
W2027911167
Cited by
84
References
2
Citations by year
2025: 1 · 2023: 1 · 2022: 4 · 2021: 3 · 2020: 4 · 2019: 5 · 2018: 2 · 2017: 6 · 2016: 3 · 2015: 6 · 2014: 10 · 2013: 7 · 2012: 8
FWCI
6.31
Type
journal article
Language
en
Open access
closed
Locations
  • Archives of Orthopaedic and Trauma Surgery (publishedVersion)
  • PubMed (publishedVersion)
  • mediaTUM – the media and publications repository of the Technical University Munich (Technical University Munich) (submittedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Tendon Structure and Treatment
  • Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
Keywords
anterior cruciate ligament reconstruction, tissue engineering, tendon allografts, dermal fibroblasts, cell seeding, semitendinosus tendon, extracellular matrix, type I collagen, versican, rabbit model, load to failure, immune rejection
MeSH terms
Analysis of Variance, Animals, Biomechanical Phenomena, Cells, Cultured, Female, Fibroblasts, Immunoenzyme Techniques, Rabbits, Tendons, Transplantation, Autologous, Transplantation, Homologous, Anterior Cruciate Ligament, Tissue Engineering

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review