Rotational instability of the knee: internal tibial rotation under a simulated pivot shift test
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Cruciate Ligaments of the Knee Joint: Anatomical. Functional and Experimental Analysis
Girgis, F. G., Marshall, J. L., & MONA JEM, A. R. S. A. (1975) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197501000-00033 · Cited by 1,485 · cited 1×
“Due to the change of orientation of the femoral origin of the AM and PL bundle the two bundles have been shown to play a signiWcant and essential role for the stabilization of the human knee [7, 8 , 19, 24, 25].”
BackgroundBiomechanical Analysis of an Anatomic Anterior Cruciate Ligament Reconstruction
Yagi, M., Wong, E. K., Kanamori, A., Debski, R. E., Fu, F. H., & Woo, S. L.-Y. (2002) · The American Journal of Sports Medicine · doi:10.1177/03635465020300050501 · Cited by 988
Loh, J. C., Fukuda, Y., Tsuda, E., Steadman, R. J., Fu, F. H., & Woo, S. L.-Y. (2003) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2003.50084 · Cited by 706 · cited 2×
“A biomechanical in vitro study comparing two femoral tunnel positions has shown that a 10 o’clock position more eVectively resists rotatory loads when compared to a 11 o’clock position as evidenced by smaller ATT and higher in situ force in the graft [ 14 ].”
MethodDaniel, D. M., Stone, M. L., Sachs, R., & Malcom, L. (1985) · The American Journal of Sports Medicine · doi:10.1177/036354658501300607 · Cited by 679 · cited 2×
“The experimental protocol and data acquired is displayed in Table 1. First, the robotic/UFS testing system found the positions of the knee that minimized all external forces and moments applied to the joint from 0° to 90°, in increments of 1°. For external loading conditions, an anterior tibial load of 134 N (to simul…”
MethodDistribution of in situ forces in the anterior cruciate ligament in response to rotatory loads
Gabriel, M. T., Wong, E. K., Woo, S. L., Yagi, M., & Debski, R. E. (2004) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)00133-5 · Cited by 673 · cited 3×
“Due to the change of orientation of the femoral origin of the AM and PL bundle the two bundles have been shown to play a signiWcant and essential role for the stabilization of the human knee [ 7 , 8, 19, 24, 25].”
BackgroundResultInfluentialEffects of postmortem storage by freezing on ligament tensile behavior
Woo, S. L.-Y., Orlando, C. A., Camp, J. F., & Akeson, W. H. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90016-3 · Cited by 572 · cited 1×
“Prior to testing, the knees were stored at i20°C and thawed for 24 h at room temperature [ 21 ].”
MethodWoo, S. L., Kanamori, A., Zeminski, J., Yagi, M., Papageorgiou, C. D., & Fu, F. H. (2002) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200206000-00003 · Cited by 538
Zantop, T., Herbort, M., Raschke, M. J., Fu, F. H., & Petersen, W. (2007) · The American Journal of Sports Medicine · doi:10.1177/0363546506294571 · Cited by 515 · cited 11×
“A recent study has shown that a signiWcant anterior tibial translation under a pivot shift mechanism is only observed if the posterolateral bundle of the ACL was sectioned [ 24 ].”
BackgroundMethodResultInfluentialSelf-citationKocher, M. S., Steadman, J. R., Briggs, K. K., Sterett, W. I., & Hawkins, R. J. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503261722 · Cited by 492 · cited 3×
“Recent literature has shown, however, that instrumented knee laxity and Lachman examination have no signiWcant relationships with symptoms and function [9, 11 ].”
BackgroundInfluentialAnatomy of the Anterior Cruciate Ligament with Regard to Its Two Bundles
Petersen, W., & Zantop, T. (2007) · Clinical Orthopaedics and Related Research · doi:10.1097/blo.0b013e31802b4a59 · Cited by 474 · cited 5×
“It is generally accepted to distinguish the anterior cruciate ligament into two functional bundles named after their tibial insertions, the anteromedial (AM) and posterolateral (PL) bundle [1, 18 , 24, 25].”
BackgroundMethodInfluentialSelf-citation
Cited by
Bedi, A., Musahl, V., Steuber, V., Kendoff, D., Choi, D., Allen, A. A., Pearle, A. D., & Altchek, D. W. (2011) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2010.07.018 · Cited by 288
Return to play following ACL reconstruction: a systematic review about strength deficits
Petersen, W., Taheri, P., Forkel, P., & Zantop, T. (2014) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-014-1992-x · Cited by 236
“It stabilizes the tibia against anteriorly directed and rotatory forces [22].”
Self-citationAmis, A. A. (2012) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-011-1864-7 · Cited by 143
“[12] have studied the effects of combined 10 Nm valgus moment and 4 Nm internal rotation torque on tibiofemoral laxity using a robot, in a very similar manner to Gabriel et al.”
Method
Metadata
- Authors
- Diermann, N., Schumacher, T., Schanz, S., Raschke, M. J., Petersen, W., & Zantop, T.
- Venue
- Archives of Orthopaedic and Trauma Surgery
- Published
- 2008-07-02
- Volume
- 129
- Issue
- 3
- Pages
- 353-358
- ISSN
- 0936-8051 (ISSN-L)
- 1434-3916
- OpenAlex
- W2074123378
- Cited by
- 159
- References
- 25
- FWCI
- 10.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.