Does cervical length and the lower placental edge thickness measurement correlates with clinical outcome in cases of complete placenta previa?
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Objectives To evaluate the effectiveness of cervical length and the lower placental edge thickness measurement in predicting the risk of antepartum hemorrhage (APH) and emergency preterm cesarean delivery in women with complete placenta previa. Methods Fifty-four cases with confirmed diagnosis of complete placenta previa in third-trimester were subjected to transvaginal sonographic measurement of cervical length and lower placental edge thickness and correlated this to clinical outcome with regards to gestational age at delivery, ante partum hemorrhage, emergency cesarean section before 36 weeks due to massive hemorrhage and neonatal birth weight. Results Antepartum bleeding and emergency cesarean section rate before 36 weeks due to massive bleeding were significantly higher in cases with thick lower placental edge or central placenta than cases with thin lower placental edge [16 cases (53.3%) vs. 5 cases (20.8%)] for the former and [14 cases (46.6%) vs. 4 cases (16.6%) for the later]. Antepartum bleeding was observed in 18 cases (51.4%) when cervical length measurements ≤30 mm of whom 16 cases (88.9%) had showed severe attack necessitated emergency cesarean delivery before 36 weeks versus 4 cases (21.1%) with cervical length ≥30 mm. By combining cervical length with lower placental edge thickness measurement sensitivity, specificity, positive predictive value (PPV) negative predictive value (NPV) and accuracy increased to 83.3, 78.4, 53.4, 79.8 and 89.7%, respectively for th…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Similarly, a prospective cohort study of 54 women with placenta praevia covering the internal os has shown that combining a cervical length of less than 30 mm and measurement of the lower placental edge thickness of more than 10 mm has a sensitivity of 83.3% and a specificity of 78.4%.58”
From Placenta Praevia and Placenta Accreta: Diagnosis and Management: Green‐top Guideline No. 27a (2019) · cites this paper as [58]
In the citing paper
“cohort studies with low risks of confounding bias have shown that cervical length is a predictor of antepartum bleeding and emergency preterm caesarean section in placenta praevia.[57][58][59][60]”
From Placenta Praevia and Placenta Accreta: Diagnosis and Management: Green‐top Guideline No. 27a (2019) · cites this paper as [58]
Citations
Cites
Placenta Previa, Placenta Accreta, and Vasa Previa
Oyelese, Y., & Smulian, J. C. (2006) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000207559.15715.98 · Cited by 975
Critical analysis of risk factors and outcome of placenta previa
Rosenberg, T., Pariente, G., Sergienko, R., Wiznitzer, A., & Sheiner, E. (2011) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-010-1598-7 · Cited by 259 · cited 1×
“3% of third-trimester pregnancies [1].”
Accuracy and Safety of Transvaginal Sonographic Placental Localization
LEERENTVELD, R. A., GILBERTS, E. C. A. M., ARNOLD, M. J. C. W. J., & WLADIMIROFF, J. W. (1990) · Obstetrics & Gynecology · doi:10.1097/00006250-199011000-00006 · Cited by 179
Ghourab, S. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2001.00420.x · Cited by 159 · cited 5×
“internal os and correlated this to the risk of APH, mode of delivery, emergency cesarean delivery and risk of prematurity [8–11, 15], but few studies added the value of lower placental edge thickness [12], and cervical length measurement and correlated this to clinical outcome in patients with placenta previa [13, 14].”
BackgroundMethodInfluentialBhide, A., Prefumo, F., Moore, J., Hollis, B., & Thilaganathan, B. (2003) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2003.02491.x · Cited by 154
Cervical length at 16â22 weeks' gestation and risk for preterm delivery
Hibbard, J. (2000) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(00)01074-7 · Cited by 122
Rozenberg, P., Gillet, A., & Ville, Y. G. (2002) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2002.00645.x · Cited by 111
Diagnosis of low‐lying placenta: can migration in the third trimester predict outcome?
Oppenheimer, L., Holmes, P., Simpson, N., & Dabrowski, A. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2001.00450.x · Cited by 102
Ultrasonographic Cervical Length and Risk of Hemorrhage in Pregnancies With Placenta Previa
Stafford, I. A., Dashe, J. S., Shivvers, S. A., Alexander, J. M., McIntire, D. D., & Leveno, K. J. (2010) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3181ea2deb · Cited by 96
Placenta previa: distance to internal os and mode of delivery
Vergani, P., Ornaghi, S., Pozzi, I., Beretta, P., Russo, F. M., Follesa, I., & Ghidini, A. (2009) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2009.06.009 · Cited by 85
Cited by
Placenta Praevia and Placenta Accreta: Diagnosis and Management: Green‐top Guideline No. 27a
Jauniaux, E., Alfirevic, Z., Bhide, A., Belfort, M., Burton, G., Collins, S., Dornan, S., Jurkovic, D., Kayem, G., Kingdom, J., et al. (2019) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.15306 · Cited by 506
McIntosh, J., Feltovich, H., Berghella, V., & Manuck, T. (2016) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2016.04.027 · Cited by 265
Using ultrasound in the clinical management of placental implantation abnormalities
Vintzileos, A. M., Ananth, C. V., & Smulian, J. C. (2015) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2015.05.059 · Cited by 145
Guideline No. 402: Diagnosis and Management of Placenta Previa
Jain, V., Bos, H., & Bujold, E. (2020) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/j.jogc.2019.07.019 · Cited by 136
Fan, D., Wu, S., Liu, L., Xia, Q., Wang, W., Guo, X., & Liu, Z. (2017) · Scientific Reports · doi:10.1038/srep40320 · Cited by 118
Metadata
- Authors
- Zaitoun, M. M., El Behery, M. M., Abd El Hameed, A. A., & Soliman, B. S.
- Affiliations
- Zagazig University (EG)
- ORCID
- Soliman, Badeea S.
- Venue
- Archives of Gynecology and Obstetrics
- Published
- 2010-11-27
- Volume
- 284
- Issue
- 4
- Pages
- 867-873
- ISSN
- 0003-9128 (ISSN-L)
- 0932-0067
- 1432-0711
- OpenAlex
- W1976380825
- Cited by
- 51
- References
- 19
- Citations by year
- 2026: 5 · 2025: 2 · 2024: 5 · 2023: 3 · 2022: 7 · 2021: 3 · 2020: 2 · 2019: 4 · 2018: 5 · 2017: 3 · 2016: 4 · 2015: 2 · 2014: 3 · 2012: 2
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Archives of Gynecology and Obstetrics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Maternal and fetal healthcare
- Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
- Health Sciences › Medicine › Obstetrics and Gynecology › Preterm Birth and Chorioamnionitis
- Keywords
- complete placenta previa, cervical length, antepartum hemorrhage, transvaginal ultrasound, third trimester
- MeSH terms
- Adult, Cervix Uteri, Cesarean Section, Egypt, Emergency Treatment, Female, Gestational Age, Humans, Placenta Previa, Predictive Value of Tests, Pregnancy, Pregnancy Outcome, Pregnancy Trimester, Third, Prospective Studies, ROC Curve, Sensitivity and Specificity, Ultrasonography, Prenatal, Cervical Length Measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Does cervical length and the lower placental edge thickness measurement correlates with clinical outcome in cases of complete placenta previa? https://app.cochat.ai/papers/10.1007/s00404-010-1737-1
- The paper
- Zaitoun, M. M., El Behery, M. M., Abd El Hameed, A. A., & Soliman, B. S. (2011). Does cervical length and the lower placental edge thickness measurement correlates with clinical outcome in cases of complete placenta previa? Archives of Gynecology and Obstetrics. https://doi.org/10.1007/s00404-010-1737-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.