Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Acoustic analysis of snoring sounds recorded with a smartphone according to obstruction site in OSAS patients

Koo, Soo Kweon, Kwon, Soon Bok, Kim, Yang Jae, Moon, JI Seung, Kim, Young Jun, Jung, Sung Hoon · 2017 · European Archives of Oto-Rhino-Laryngology

Abstract

Snoring is a sign of increased upper airway resistance and is the most common symptom suggestive of obstructive sleep apnea. Acoustic analysis of snoring sounds is a non-invasive diagnostic technique and may provide a screening test that can determine the location of obstruction sites. We recorded snoring sounds according to obstruction level, measured by DISE, using a smartphone and focused on the analysis of formant frequencies. The study group comprised 32 male patients (mean age 42.9 years). The spectrogram pattern, intensity (dB), fundamental frequencies (F 0 ), and formant frequencies (F 1 , F 2 , and F 3 ) of the snoring sounds were analyzed for each subject. On spectrographic analysis, retropalatal level obstruction tended to produce sharp and regular peaks, while retrolingual level obstruction tended to show peaks with a gradual onset and decay. On formant frequency analysis, F 1 (retropalatal level vs. retrolingual level: 488.1 ± 125.8 vs. 634.7 ± 196.6 Hz) and F 2 (retropalatal level vs. retrolingual level: 1267.3 ± 306.6 vs. 1723.7 ± 550.0 Hz) of retrolingual level obstructions showed significantly higher values than retropalatal level obstruction (p < 0.05). This suggests that the upper airway is more severely obstructed with retrolingual level obstruction and that there is a greater change in tongue position. Acoustic analysis of snoring is a non-invasive diagnostic technique that can be easily applied at a relatively low cost. The analysis of formant frequencie…

Overview

Integrity signals

Registry

Crossref · 10.1007/s00405-016-4335-4

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 23 references

Cited by

See all 47

Metadata

Authors
Koo, S. K., Kwon, S. B., Kim, Y. J., Moon, J. S., Kim, Y. J., & Jung, S. H.
Affiliations
Pusan National University (KR)
Corresponding author
Koo, Soo Kweon
Venue
European Archives of Oto-Rhino-Laryngology
Published
2016-10-05
Volume
274
Issue
3
Pages
1735-1740
ISSN
  • 0937-4477 (ISSN-L)
  • 1434-4726
OpenAlex
W2528738660
Cited by
47
References
23
Citations by year
2025: 3 · 2024: 2 · 2023: 11 · 2022: 8 · 2021: 4 · 2020: 8 · 2019: 4 · 2018: 5 · 2017: 2
FWCI
2.95
Type
journal article
Language
en
Open access
closed
Locations
  • European Archives of Oto-Rhino-Laryngology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
Keywords
snoring, obstructive sleep apnea, acoustic analysis, formant frequencies, upper airway obstruction, smartphone recordings, non-invasive screening, tongue position
MeSH terms
Smartphone, Acoustics, Adult, Airway Resistance, Female, Humans, Male, Middle Aged, Snoring, Sound, Tongue, Polysomnography, Sleep Apnea, Obstructive, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Acoustic analysis of snoring sounds recorded with a smartphone according to obstruction site in OSAS patients. https://app.cochat.ai/papers/10.1007/s00405-016-4335-4
The paper
Koo, S. K., Kwon, S. B., Kim, Y. J., Moon, J. S., Kim, Y. J., & Jung, S. H. (2017). Acoustic analysis of snoring sounds recorded with a smartphone according to obstruction site in OSAS patients. European Archives of Oto-Rhino-Laryngology. https://doi.org/10.1007/s00405-016-4335-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.