The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Characteristics of the Snoring Noise in Patients with and without Occlusive Sleep Apnea
Abstract
We analyzed snoring noise from 10 nonapneic heavy snorers and nine patients with obstructive sleep apnea (OSA). Sound was recorded simultaneously through two microphones, one attached to the manubrium sterni and one suspended in the air 15 cm from the patient's head. Signals were stored on magnetic tape, digitized, and displayed in the time and frequency domains. Most of the power of snoring noise was below 2,000 Hz, and the peak power was usually below 500 Hz. When snores were generated during nose-only breathing (nasal snores), the sound spectrum was made up of a series of discrete, sharp peaks, with a fundamental note and harmonics similar to the spectrum of voiced sounds. When snores were generated during breathing through nose and mouth (oronasal snores), the spectra showed a mixture of sharp peaks and broad-band white noise. Patients with apnea showed a sequence of snores with spectral characteristics that varied markedly through an apnea-respiration cycle. The first postapneic snore consisted mainly of broad-band white noise with relatively more power at higher frequencies, so that the ratio of power above 800 Hz to power below 800 Hz could be used to separate snorers from patients with OSA. Other breaths in the cycle resembled oronasal or nasal snores in nonapneic subjects. Characteristics of the noise give information about the possible mechanism of sound generation and thus about the behavior of the pharynx during snoring. Quality of snoring sound may help to separate patients with obstructive apnea from those with simple snoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Upper airway pressure-flow relationships in obstructive sleep apnea
Smith, P. L., Wise, R. A., Gold, A. R., Schwartz, A. R., & Permutt, S. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.64.2.789 · Cited by 446
Pharyngeal Size in Snorers, Nonsnorers, and Patients with Obstructive Sleep Apnea
Bradley, T. D., Brown, I. G., Grossman, R. F., Zamel, N., Martinez, D., Phillipson, E. A., & Hoffstein, V. (1986) · New England Journal of Medicine · doi:10.1056/nejm198611203152105 · Cited by 330
Cited by
Respiratory Sounds: Advances Beyond the Stethoscope
PASTERKAMP, H., KRAMAN, S. S., & WODICKA, G. R. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.3.9701115 · Cited by 634
Computer based sleep recording and analysis
Penzel, T., & Conradt, R. (2000) · Sleep Medicine Reviews · doi:10.1053/smrv.1999.0087 · Cited by 235
Sleep Apnea Monitoring using mobile phones
Alqassim, S., Ganesh, M., Khoja, S., Zaidi, M., Aloul, F., & Sagahyroon, A. (2012) · 2012 IEEE 14th International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom.2012.6379457 · Cited by 55
Koo, S. K., Kwon, S. B., Kim, Y. J., Moon, J. S., Kim, Y. J., & Jung, S. H. (2017) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-016-4335-4 · Cited by 47
Djupesland, P. G., Skatvedt, O., & Borgersen, A. K. (2001) · American Journal of Rhinology · doi:10.2500/105065801781543745 · Cited by 47
Metadata
- Authors
- Perez-Padilla, J. R., Slawinski, E., Difrancesco, L. M., Feige, R. R., Remmers, J. E., & Whitelaw, W. A.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-03
- Volume
- 147
- Issue
- 3
- Pages
- 635-644
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W1995382472
- Cited by
- 182
- References
- 2
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characteristics of the Snoring Noise in Patients with and without Occlusive Sleep Apnea. https://app.cochat.ai/papers/10.1164/ajrccm/147.3.635
- The paper
- Perez-Padilla, J. R., Slawinski, E., Difrancesco, L. M., Feige, R. R., Remmers, J. E., & Whitelaw, W. A. (1993). Characteristics of the Snoring Noise in Patients with and without Occlusive Sleep Apnea. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/147.3.635
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.