The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Estimation of V?O2max from the ratio between HRmax and HRrest ? the Heart Rate Ratio Method
Open accessAbstract
The effects of training and/or ageing upon maximal oxygen uptake ( VO(2max)) and heart rate values at rest (HR(rest)) and maximal exercise (HR(max)), respectively, suggest a relationship between VO(2max) and the HR(max)-to-HR(rest) ratio which may be of use for indirect testing of VO(2max). Fick principle calculations supplemented by literature data on maximum-to-rest ratios for stroke volume and the arterio-venous O(2) difference suggest that the conversion factor between mass-specific VO(2max) (ml.min(-1).kg(-1)) and HR(max).HR(rest)(-1) is approximately 15. In the study we experimentally examined this relationship and evaluated its potential for prediction of VO(2max). VO(2max) was measured in 46 well-trained men (age 21-51 years) during a treadmill protocol. A subgroup ( n=10) demonstrated that the proportionality factor between HR(max).HR(rest)(-1) and mass-specific VO(2max) was 15.3 (0.7) ml.min(-1).kg(-1). Using this value, VO(2max) in the remaining 36 individuals could be estimated with an SEE of 0.21 l.min(-1) or 2.7 ml.min(-1).kg(-1) (approximately 4.5%). This compares favourably with other common indirect tests. When replacing measured HR(max) with an age-predicted one, SEE was 0.37 l.min(-1) and 4.7 ml.min(-1).kg(-1) (approximately 7.8%), which is still comparable with other indirect tests. We conclude that the HR(max)-to-HR(rest) ratio may provide a tool for estimation of VO(2max) in well-trained men. The applicability of the test principle in relation to other groups will have to await direct validation. VO(2max) can be estimated indirectly from the measured HR(max)-to-HR(rest) ratio with an accuracy that compares favourably with that of other common indirect tests. The results also suggest that the test may be of use for VO(2max) estimation based on resting measurements alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Age-predicted maximal heart rate revisited
Tanaka, H., Monahan, K. D., & Seals, D. R. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01054-8 · Cited by 3,775 · cited 6×
“Ageing is associated with decrements in both _ V O2max and HRmax (Tanaka et al. 2001).”
BackgroundMethodInfluentialÅstrand, P. O., & Ryhming, I. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.7.2.218 · Cited by 1,558
Cited by
Consensus on Exercise Reporting Template (CERT): Explanation and elaboration statement
Slade, S. C., Dionne, C. E., Underwood, M., & Buchbinder, R. (2016) · British Journal of Sports Medicine · doi:10.1136/bjsports-2016-096651 · Cited by 961
Reliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Internally mixed soot, sulfates, and organic matter in aerosol particles from Mexico City
Adachi, K., & Buseck, P. R. (2008) · Atmospheric Chemistry and Physics · doi:10.5194/acp-8-6469-2008 · Cited by 291
Air quality in North America's most populous city – overview of the MCMA-2003 campaign
Molina, L. T., Kolb, C. E., de Foy, B., Lamb, B. K., Brune, W. H., Jimenez, J. L., Ramos-Villegas, R., Sarmiento, J., Paramo-Figueroa, V. H., Cardenas, B., et al. (2007) · Atmospheric Chemistry and Physics · doi:10.5194/acp-7-2447-2007 · Cited by 263
Intralysosomal iron chelation protects against oxidative stress‐induced cellular damage
Kurz, T., Gustafsson, B., & Brunk, U. T. (2006) · The FEBS Journal · doi:10.1111/j.1742-4658.2006.05321.x · Cited by 175
Metadata
- Authors
- Uth, N., S�rensen, H., Overgaard, K., & Pedersen, P. K.
- Venue
- European Journal of Applied Physiology
- Published
- 2003-11-18
- Volume
- 91
- Issue
- 1
- Pages
- 111-115
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- OpenAlex
- W2082259973
- Cited by
- 225
- References
- 3
- FWCI
- 7.68
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimation of V?O2max from the ratio between HRmax and HRrest ? the Heart Rate Ratio Method. https://app.cochat.ai/papers/10.1007/s00421-003-0988-y
- The paper
- Uth, N., S�rensen, H., Overgaard, K., & Pedersen, P. K. (2004). Estimation of V?O2max from the ratio between HRmax and HRrest ? the Heart Rate Ratio Method. European Journal of Applied Physiology. https://doi.org/10.1007/s00421-003-0988-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.