Give me a sign: decoding four complex hand gestures based on high-density ECoG
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The increasing understanding of human brain functions makes it possible to directly interact with the brain for therapeutic purposes. Implantable brain computer interfaces promise to replace or restore motor functions in patients with partial or complete paralysis. We postulate that neuronal states associated with gestures, as they are used in the finger spelling alphabet of sign languages, provide an excellent signal for implantable brain computer interfaces to restore communication. To test this, we evaluated decodability of four gestures using high-density electrocorticography in two participants. The electrode grids were located subdurally on the hand knob area of the sensorimotor cortex covering a surface of 2.5-5.2 cm(2). Using a pattern-matching classification approach four types of hand gestures were classified based on their pattern of neuronal activity. In the two participants the gestures were classified with 97 and 74% accuracy. The high frequencies (>65 Hz) allowed for the best classification results. This proof-of-principle study indicates that the four gestures are associated with a reliable and discriminable spatial representation on a confined area of the sensorimotor cortex. This robust representation on a small area makes hand gestures an interesting control feature for an implantable BCI to restore communication for severely paralyzed people.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 2×
“We argue here that the topographical organization of the hand in the sensorimotor cortex provides a control signal with many important advantageous characteristics for implantable communicative BCIs.”
PENFIELD, W., & BOLDREY, E. (1937) · Brain · doi:10.1093/brain/60.4.389 · Cited by 4,188
Distributed and overlapping representations of faces and objects in ventral temporal cortex
Haxby, J. V., Gobbini, M. I., Furey, M. L., Ishai, A., Schouten, J. L., & Pietrini, P. (2001) · Science · doi:10.1126/science.1063736 · Cited by 3,940 · cited 1×
“The single trial data were classified using apattern (template) correlation approach with a leave-one-out cross-validation scheme (Haxby et al. 2001; Misaki et al. 2010).”
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · cited 4×
“A high degree of robot arm control was achieved in tetra-plegic patients using intracranial electrodes (Hochberg et al. 2012; Collinger et al. 2012; Wang et al. 2013).”
InfluentialHigh-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · cited 4×
“A high degree of robot arm control was achieved in tetra-plegic patients using intracranial electrodes (Hochberg et al. 2012; Collinger et al. 2012; Wang et al. 2013).”
InfluentialSingle-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138
BCILAB: a platform for brain–computer interface development
Kothe, C. A., & Makeig, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056014 · Cited by 412 · cited 1×
“For this we used the MATLAB extension BCILAB (Kothe and Makeig 2013), with the same feature set as was used for the pattern correlation analysis.”
A Wireless Brain-Machine Interface for Real-Time Speech Synthesis
Guenther, F. H., Brumberg, J. S., Wright, E. J., Nieto-Castanon, A., Tourville, J. A., Panko, M., Law, R., Siebert, S. A., Bartels, J. L., Andreasen, D. S., et al. (2009) · PLoS ONE · doi:10.1371/journal.pone.0008218 · Cited by 306
Electrocorticographic control of a prosthetic arm in paralyzed patients
Yanagisawa, T., Hirata, M., Saitoh, Y., Kishima, H., Matsushita, K., Goto, T., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2012) · Annals of Neurology · doi:10.1002/ana.22613 · Cited by 256 · cited 1×
“…representation of the primary motor cortex is largely preserved in tetraplegics after extensive periods of paralysis (Shoham et al. 2001; Corb-etta et al. 2002; Sabbah et al. 2002; Cramer et al. 2005; Hotz-Boendermaker et al. 2008; Mattia et al. 2009, but see also Yanagisawa et al. 2012).”
Huggins, J. E., Wren, P. A., & Gruis, K. L. (2011) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482968.2011.572978 · Cited by 215 · cited 1×
“While participant 1 performed with 97 % accuracy above the 90 % criterion that is requested by potential BCI users (Huggins et al. 2011), participant 2 did not (with maximal 74 %).”
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Lazarou, I., Nikolopoulos, S., Petrantonakis, P. C., Kompatsiaris, I., & Tsolaki, M. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00014 · Cited by 335
Advances in human intracranial electroencephalography research, guidelines and good practices
Mercier, M. R., Dubarry, A.-S., Tadel, F., Avanzini, P., Axmacher, N., Cellier, D., Vecchio, M. D., Hamilton, L. S., Hermes, D., Kahana, M. J., et al. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119438 · Cited by 229
Self-citationHotson, G., McMullen, D. P., Fifer, M. S., Johannes, M. S., Katyal, K. D., Para, M. P., Armiger, R., Anderson, W. S., Thakor, N. V., Wester, B. A., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026017 · Cited by 201
Decoding spoken phonemes from sensorimotor cortex with high-density ECoG grids
Ramsey, N. F., Salari, E., Aarnoutse, E. J., Vansteensel, M. J., Bleichner, M. G., & Freudenburg, Z. V. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.011 · Cited by 124
Self-citation
Metadata
- Authors
- Bleichner, M. G., Freudenburg, Z. V., Jansma, J. M., Aarnoutse, E. J., Vansteensel, M. J., & Ramsey, N. F.
- Venue
- Brain Structure and Function
- Published
- 2014-10-02
- Volume
- 221
- Issue
- 1
- Pages
- 203-216
- ISSN
- 1863-2653 (ISSN-L)
- 1863-2661
- OpenAlex
- W2089318762
- Cited by
- 83
- References
- 11
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Give me a sign: decoding four complex hand gestures based on high-density ECoG. https://app.cochat.ai/papers/10.1007/s00429-014-0902-x
- The paper
- Bleichner, M. G., Freudenburg, Z. V., Jansma, J. M., Aarnoutse, E. J., Vansteensel, M. J., & Ramsey, N. F. (2016). Give me a sign: decoding four complex hand gestures based on high-density ECoG. Brain Structure and Function. https://doi.org/10.1007/s00429-014-0902-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.