Utility of near-infrared light devices for pediatric peripheral intravenous cannulation: a systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
AbstractWe investigated the utility of near-infrared (NIR) light devices for peripheral intravenous cannulation (PIVC) in pediatric patients. We searched three databases, MEDLINE, EMBASE, and the Cochrane CENTRAL. Randomized controlled trials that compared PIVC using NIR light devices and the “traditional” method (with no assistive device) were included. The primary outcome was a failure rate at the first attempt, and the effect size was measured by the risk ratio for failure. Subgroup analysis was performed according to control group risk for failure at first attempt as an indicator of difficult procedure (low vs. high). Eleven studies were included in the meta-analysis. There was no significant difference in the primary outcome between the two methods (risk ratio 1.03, confidence interval 0.89–1.20, I2 = 48 %). In a subgroup analysis, the subgroup difference between subsets of low and high control group risk was significant (I2 = 83 %). In the subset of the high control group risk, using NIR light devices showed a lower risk for failure than the traditional method (risk ratio 0.81, confidence interval 0.64–1.01, I2 = 0 %). Conclusion: Using NIR light devices did not have an impact on overall failure rate at the first attempt at PIVC in pediatric patients.What is Known:• Near-infrared light devices have been used to help vascular access especially for the pediatric patients. But, their utilities reported in previous studies were conflicting.What is New:• From this study, we could not find out overall benefit of using near-infrared light devices for pediatric peripheral intravenous cannulation. But, this device might be useful for the patients in a difficult condition of successful cannulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deeks, J. J. (2002) · Statistics in Medicine · doi:10.1002/sim.1188 · Cited by 660 · cited 2×
“When study purpose is to reduce adverse outcomes, the risk ratio of adverse outcomes is known to be more consistent than the risk ratio of nonevents [10].”
Cited by
Yalçınlı, S., Karbek Akarca, F., Can, Ö., Uz, İ., & Konakçı, G. (2022) · Prehospital and Disaster Medicine · doi:10.1017/s1049023x21001217 · Cited by 23
Hosseini, S. J., Firooz, M., Yazdi, K., Abdollahi, M., Hosseini, S. R., & Ramezani, M. (2025) · The Journal of Vascular Access · doi:10.1177/11297298241259843 · Cited by 6
Drugeon, B., Schults, J. A., Ray‐Barruel, G., Xu, G. (., Ball, D., Yasuda, H., Drugeon, R., Mercier, J., Mihala, G., Barker, N., et al. (2026) · Journal of Advanced Nursing · doi:10.1111/jan.17007 · Cited by 3
“IR devices have been mainly evaluated for pre-anaesthetic intravenous cannulation of children (Annalyn et al. 2024; Park et al. 2016; Vyas et al. 2021); results were pooled in a meta-analysis that showed first attempt insertion success, pain scores and duration of the procedure were similar between…”
Metadata
- Authors
- Park, J. M., Kim, M. J., Yim, H. W., Lee, W.-C., Jeong, H., & Kim, N. J.
- Venue
- European Journal of Pediatrics
- Published
- 2016-10-26
- Volume
- 175
- Issue
- 12
- Pages
- 1975-1988
- ISSN
- 0340-6199 (ISSN-L)
- 1432-1076
- OpenAlex
- W2543717691
- Cited by
- 39
- References
- 1
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Utility of near-infrared light devices for pediatric peripheral intravenous cannulation: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1007/s00431-016-2796-5
- The paper
- Park, J. M., Kim, M. J., Yim, H. W., Lee, W.-C., Jeong, H., & Kim, N. J. (2016). Utility of near-infrared light devices for pediatric peripheral intravenous cannulation: a systematic review and meta-analysis. European Journal of Pediatrics. https://doi.org/10.1007/s00431-016-2796-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.