Abstract

Objectives: Successful placement of a peripheral intravenous catheter (PIVC) on the first attempt is an important outcome for difficult vascular access (DVA) patients. This study compared standard technique, ultrasonography (USG), and near-infrared light (NIR) in terms of success in the first attempt in patients with DVA. Methods: This was a prospective, randomized controlled study. The study was conducted in a tertiary care hospital. Emergency department patients who describe DVA history, have no visible or palpable veins, and were assessed by the nurse to have a difficult PIVC were included to study. The PIVC procedure was performed on patients by standard, USG, or NIR device techniques. For all approaches, the success of the first attempt was the primary aim. Total procedure time, the total number of attempts, and the need for rescue intervention were secondary aims. Results: This study evaluated 270 patients. The first attempt success rates for USG, standard, and NIR methods were 78.9%, 62.2%, and 58.9%, respectively. The rate of first attempt success was higher in patients who underwent USG (USG versus standard, P = .014; USG versus NIR, P = .004; standard versus NIR, P = .648). The total median (IQR) procedure time for USG, standard, and NIR methods was 107 (69-228), 72 (47-134), and 82 (61-163) seconds, respectively. The total procedure time was longer in patients undergoing USG (standard versus USG, P <.001; NIR versus USG, P = .035; standard versus NIR, P = .055). The total median (IQR) number of attempts of USG, standard, and NIR methods were 1 (1-1), 1 (1-2), and 1 (1-2), respectively. A difference was found among the groups regarding the total number of attempts (USG versus NIR, P = .015; USG versus standard P = .108; standard versus NIR, P = .307). No difference was found among groups in terms of the need for rescue methods. Conclusion: It was found that USG increases the success of the first attempt compared with the standard method and NIR in patients with DVA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s1049023x21001217

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Research works printed but not linked: 2

  1. Kuo, 2017, I-Jung F, Wei-Jing L. The efficacy of near-infrared devices in facilitating peripheral intravenous access in children: a systematic review and subgroup meta-analysis, Hu li za zhi., 64, 69
  2. Liu, 2014, Eur J Emerg Med., 21, 18

Cited by

See all 23

Metadata

Authors
Yalçınlı, S., Karbek Akarca, F., Can, Ö., Uz, İ., & Konakçı, G.
Affiliations
  • Ege University (TR)
  • İzmir Demokrasi Üniversitesi (TR)
Venue
Prehospital and Disaster Medicine
Published
2021-12-06
Volume
37
Issue
1
Pages
65-70
ISSN
  • 0882-7397 (ISSN-L)
  • 1049-023X
  • 1945-1938
OpenAlex
W4200055357
Cited by
23
References
26
Citations by year
2026: 5 · 2025: 6 · 2024: 6 · 2023: 2 · 2022: 4
FWCI
3.67
Type
journal article
Language
en
Open access
Locations
  • Prehospital and Disaster Medicine (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
Ege Üniversitesi
Topics
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Vascular Procedures and Complications
  • Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
Keywords
peripheral venous catheterization, first-attempt success rate, near-infrared light, emergency department patients, procedure time, number of attempts, rescue interventions
MeSH terms
Catheterization, Peripheral, Emergency Service, Hospital, Humans, Prospective Studies, Ultrasonography, Ultrasonography, Interventional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Standard Technique, Ultrasonography, and Near-Infrared Light in Difficult Peripheral Vascular Access: A Randomized Controlled Trial. https://app.cochat.ai/papers/10.1017/s1049023x21001217
The paper
Yalçınlı, S., Karbek Akarca, F., Can, Ö., Uz, İ., & Konakçı, G. (2022). Comparison of Standard Technique, Ultrasonography, and Near-Infrared Light in Difficult Peripheral Vascular Access: A Randomized Controlled Trial. Prehospital and Disaster Medicine. https://doi.org/10.1017/s1049023x21001217

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.