Cole–Cole, linear and multivariate modeling of capacitance data for on-line monitoring of biomass
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This work evaluates three techniques of calibrating capacitance (dielectric) spectrometers used for on-line monitoring of biomass: modeling of cell properties using the theoretical Cole–Cole equation, linear regression of dual-frequency capacitance measurements on biomass concentration, and multivariate (PLS) modeling of scanning dielectric spectra. The performance and robustness of each technique is assessed during a sequence of validation batches in two experimental settings of differing signal noise. In more noisy conditions, the Cole–Cole model had significantly higher biomass concentration prediction errors than the linear and multivariate models. The PLS model was the most robust in handling signal noise. In less noisy conditions, the three models performed similarly. Estimates of the mean cell size were done additionally using the Cole–Cole and PLS models, the latter technique giving more satisfactory results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152 · cited 1×
“One of the most common theoretical ways of describing the dielectric properties of cell suspensions and the b-dispersion is to use the Cole–Cole equation [ 26 ].”
Method
Cited by
Wechselberger, P., Sagmeister, P., & Herwig, C. (2013) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-012-0848-4 · Cited by 102
“by coulter principle) or radiofrequency scanning, as shown by other authors [40], are required to fully identify the source of variability.”
MethodKonakovsky, V., Clemens, C., Müller, M., Bechmann, J., Berger, M., Schlatter, S., & Herwig, C. (2016) · Bioengineering · doi:10.3390/bioengineering3010005 · Cited by 44
Universal capacitance model for real-time biomass in cell culture
Konakovsky, V., Yagtu, A., Clemens, C., Müller, M., Berger, M., Schlatter, S., & Herwig, C. (2015) · Sensors · doi:10.3390/s150922128 · Cited by 41
“, after dilution or wrong classification between dead and viable cells) are the prime reasons for offsets [3,5,10].”
BackgroundMachleid, R., Nunna, S., George, A., Austerjost, J., Tomala, M., & Surowiec, I. (2025) · Engineering in Life Sciences · doi:10.1002/elsc.70004 · Cited by 4
Metadata
- Authors
- Dabros, M., Dennewald, D., Currie, D. J., Lee, M. H., Todd, R. W., Marison, I. W., & von Stockar, U.
- Venue
- Bioprocess and Biosystems Engineering
- Published
- 2008-06-11
- Volume
- 32
- Issue
- 2
- Pages
- 161-173
- ISSN
- 1615-7591 (ISSN-L)
- 1615-7605
- OpenAlex
- W2061106634
- Cited by
- 72
- References
- 1
- FWCI
- 1.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cole–Cole, linear and multivariate modeling of capacitance data for on-line monitoring of biomass. https://app.cochat.ai/papers/10.1007/s00449-008-0234-4
- The paper
- Dabros, M., Dennewald, D., Currie, D. J., Lee, M. H., Todd, R. W., Marison, I. W., & von Stockar, U. (2009). Cole–Cole, linear and multivariate modeling of capacitance data for on-line monitoring of biomass. Bioprocess and Biosystems Engineering. https://doi.org/10.1007/s00449-008-0234-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.