CoChat

Development of a Non-invasive Device for Swallow Screening in Patients at Risk of Oropharyngeal Dysphagia: Results from a Prospective Exploratory Study

Open access
Steele, Catriona M., Mukherjee, Rajat, Kortelainen, Juha M., Pölönen, Harri, Jedwab, Michael, Brady, Susan L., Theimer, Kayla Brinkman, Langmore, Susan, Riquelme, Luis F., Swigert, Nancy B., Bath, Philip M., Goldstein, Larry B., Hughes, Richard L., Leifer, Dana, Lees, Kennedy R., Meretoja, Atte, Muehlemann, Natalia · 2019 · Dysphagia
Cited by 52

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Oropharyngeal dysphagia is prevalent in several at-risk populations, including post-stroke patients, patients in intensive care and the elderly. Dysphagia contributes to longer hospital stays and poor outcomes, including pneumonia. Early identification of dysphagia is recommended as part of the evaluation of at-risk patients, but available bedside screening tools perform inconsistently. In this study, we developed algorithms to detect swallowing impairment using a novel accelerometer-based dysphagia detection system (DDS). A sample of 344 individuals was enrolled across seven sites in the United States. Dual-axis accelerometry signals were collected prospectively with simultaneous videofluoroscopy (VFSS) during swallows of liquid barium stimuli in thin, mildly, moderately and extremely thick consistencies. Signal processing classifiers were trained using linear discriminant analysis and 10,000 random training-test data splits. The primary objective was to develop an algorithm to detect impaired swallowing safety with thin liquids with an area under receiver operating characteristic curve (AUC) > 80% compared to the VFSS reference standard. Impaired swallowing safety was identified in 7.2% of the thin liquid boluses collected. At least one unsafe thin liquid bolus was found in 19.7% of participants, but participants did not exhibit impaired safety consistently. The DDS classifier algorithms identified participants with impaired thin liquid swallowing safety with a mean AUC of 81.5%, (sensitivity 90.4%, specificity 60.0%). Thicker consistencies were effective for reducing the frequency of penetration-aspiration. This DDS reached targeted performance goals in detecting impaired swallowing safety with thin liquids. Simultaneous measures by DDS and VFSS, as performed here, will be used for future validation studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00455-018-09974-5

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 52

Metadata

Authors
Steele, C. M., Mukherjee, R., Kortelainen, J. M., Pölönen, H., Jedwab, M., Brady, S. L., Theimer, K. B., Langmore, S., Riquelme, L. F., Swigert, N. B., Bath, P. M., Goldstein, L. B., Hughes, R. L., Leifer, D., Lees, K. R., Meretoja, A., & Muehlemann, N.
Venue
Dysphagia
Published
2019-01-05
Volume
34
Issue
5
Pages
698-707
ISSN
  • 0179-051X (ISSN-L)
  • 1432-0460
OpenAlex
W2907415686
Cited by
52
References
3
FWCI
10.51
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development of a Non-invasive Device for Swallow Screening in Patients at Risk of Oropharyngeal Dysphagia: Results from a Prospective Exploratory Study. https://app.cochat.ai/papers/10.1007/s00455-018-09974-5
The paper
Steele, C. M., Mukherjee, R., Kortelainen, J. M., Pölönen, H., Jedwab, M., Brady, S. L., Theimer, K. B., Langmore, S., Riquelme, L. F., Swigert, N. B., Bath, P. M., Goldstein, L. B., Hughes, R. L., Leifer, D., Lees, K. R., Meretoja, A., & Muehlemann, N. (2019). Development of a Non-invasive Device for Swallow Screening in Patients at Risk of Oropharyngeal Dysphagia: Results from a Prospective Exploratory Study. Dysphagia. https://doi.org/10.1007/s00455-018-09974-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.