In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty: an experimental study in pigs
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Klinge, U., Park, J.-K., & Klosterhalfen, B. (2013) · Pathobiology · doi:10.1159/000348446 · Cited by 1,783
Impact of Polymer Pore Size on the Interface Scar Formation in a Rat Model
Klinge, U., Klosterhalfen, B., Birkenhauer, V., Junge, K., Conze, J., & Schumpelick, V. (2002) · Journal of Surgical Research · doi:10.1006/jsre.2002.6358 · Cited by 340
Shrinking of polypropylene mesh in vivo: an experimental study in dogs
Klinge, U., Klosterhalfen, B., Müller, M., Öttinger, A. P., & Schumpelick, V. (2003) · The European Journal of Surgery · doi:10.1080/110241598750005156 · Cited by 308 · cited 2×
“In contrast, in addition to more pronounced scar formation, we also saw three cases of folding with the Atrium mesh, an event that did not occur with any of the other three meshes [15, 17, 20, 23].”
BackgroundResultMB, B. F. G. J. M.-S., & DS, F. L. E. H. (1998) · Journal of the American College of Surgeons · doi:10.1016/s1072-7515(98)00002-7 · Cited by 279 · cited 1×
“Three months postoperatively, the surface area of the heavyweight Atrium showed an average reduction to 87% of the original—a figure that was somewhat better than that reported in earlier publications [1, 16, 17, 24, 25].”
ResultModified mesh for hernia repair that is adapted to the physiology of the abdominal wall
Klinge, U., Klosterhalfen, B., Conze, J., Limberg, W., Obolenski, B., Öttinger, A. P., & Schumpelick, V. (2003) · European Journal of Surgery · doi:10.1080/110241598750005138 · Cited by 269 · cited 2×
“Nevertheless, the tensile strength of all the implants was above the physiological bursting strength of the abdominal wall [16, 26].”
BackgroundResultFunctional and morphologic properties of a modified mesh for inguinal hernia repair
Junge, K., Klinge, U., Rosch, R., Klosterhalfen, B., & Schumpelick, V. (2002) · World Journal of Surgery · doi:10.1007/s00268-002-6444-z · Cited by 164
Bellón, J. M., Buján, J., Contreras, L. A., Martín, A. C.-S., & Jurado, F. (1996) · PubMed · Cited by 137
Schumpelick, V., Klinge, U., Welty, G., & Klosterhalfen, B. (1999) · Der Chirurg · doi:10.1007/s001040050737 · Cited by 128
F., G., J., P., M., B.-S., F., C., A., S., S., T., & A., M. (2001) · Hernia · doi:10.1007/s100290100001 · Cited by 110
Schumpelick, V., Klosterhalfen, B., Müller, M., & Klinge, U. (1999) · Der Chirurg · doi:10.1007/s001040050666 · Cited by 109 · cited 4×
“Consequently, further optimization of the materials used for such implants is still needed [9, 25].”
BackgroundResultInfluentialAbdominal adhesions to prosthetic mesh evaluated by laparoscopy and electron microscopy1
Baptista, M. L., Bonsack, M. E., Felemovicius, I., & Delaney, J. P. (2000) · Journal of the American College of Surgeons · doi:10.1016/s1072-7515(99)00277-x · Cited by 97 · cited 2×
“Because prosthetic patches applied using the TEP technique have to be of a certain minimum size, a reduction in the material introduced can only be achieved by reducing its weight [2, 21].”
Functional assessment and tissue response of short- and long-term absorbable surgical meshes
Klinge, U., Schumpelick, V., & Klosterhalfen, B. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00299-4 · Cited by 92
Schumpèlick, V. (1999) · Der Chirurg · doi:10.1007/s001040050733 · Cited by 76
Biomaterials for "tension-free" hernioplasties and principles of their applications.
Amid, P. K., Lichtenstein, I. L., Shulman, A. G., & Hakakha, M. (1995) · PubMed · Cited by 44
Comparison of Meshes for the Repair of Experimental Abdominal Wall Defects
Hengirmen, S., Cete, M., Soran, A., Aksoy, F., Sencer, H., & Okay, E. (1998) · Journal of Investigative Surgery · doi:10.3109/08941939809032208 · Cited by 22
Marois, Y., Cadi, R., Gourdon, J. C., Fatouraee, N., King, M. W., Zhang, Z., & Guidoin, R. (2000) · Artificial Organs · doi:10.1046/j.1525-1594.2000.06547.x · cited 1×
“In contrast, in addition to more pronounced scar formation, we also saw three cases of folding with the Atrium mesh, an event that did not occur with any of the other three meshes [15, 17, 20, 23].”
Background
Cited by
Polymeric Biomaterials for Medical Implants and Devices
Teo, A. J. T., Mishra, A., Park, I., Kim, Y.-J., Park, W.-T., & Yoon, Y.-J. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00429 · Cited by 778
Schmedt, C. G., Sauerland, S., & Bittner, R. (2005) · Surgical Endoscopy · doi:10.1007/s00464-004-9126-0 · Cited by 439
The lightweight and large porous mesh concept for hernia repair
Klosterhalfen, B., Junge, K., & Klinge, U. (2005) · Expert Review of Medical Devices · doi:10.1586/17434440.2.1.103 · Cited by 380
Cobb, W. S., Burns, J. M., Peindl, R. D., Carbonell, A. M., Matthews, B. D., Kercher, K. W., & Heniford, B. T. (2006) · Journal of Surgical Research · doi:10.1016/j.jss.2006.05.022 · Cited by 178
Pal, A. K., Mohanty, A. K., & Misra, M. (2021) · RSC Advances · doi:10.1039/d1ra04060j · Cited by 169
Metadata
- Authors
- Scheidbach, H., Tamme, C., Tannapfel, A., Lippert, H., & K�ckerling, F.
- Venue
- Surgical Endoscopy
- Published
- 2004-02-01
- Volume
- 18
- Issue
- 2
- Pages
- 211-220
- ISSN
- 0930-2794 (ISSN-L)
- 1432-2218
- OpenAlex
- W1967784569
- Cited by
- 174
- References
- 16
- FWCI
- 8.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.