The DOI matches its Crossref record.
What is going on in augmented reality simulation in laparoscopic surgery?
Open accessAbstract
BACKGROUND: To prevent unnecessary errors and adverse results of laparoscopic surgery, proper training is of paramount importance. A safe way to train surgeons for laparoscopic skills is simulation. For this purpose traditional box trainers are often used, however they lack objective assessment of performance. Virtual reality laparoscopic simulators assess performance, but lack realistic haptic feedback. Augmented reality (AR) combines a virtual reality (VR) setting with real physical materials, instruments, and feedback. This article presents the current developments in augmented reality laparoscopic simulation. METHODS: Pubmed searches were performed to identify articles regarding surgical simulation and augmented reality. Identified companies manufacturing an AR laparoscopic simulator received the same questionnaire referring to the features of the simulator. RESULTS: Seven simulators that fitted the definition of augmented reality were identified during the literature search. Five of the approached manufacturers returned a completed questionnaire, of which one simulator appeared to be VR and was therefore not applicable for this review. CONCLUSION: Several augmented reality simulators have been developed over the past few years and they are improving rapidly. We recommend the development of AR laparoscopic simulators for component tasks of procedural training. AR simulators should be implemented in current laparoscopic training curricula, in particular for laparoscopic suturing training.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Systematic review on the effectiveness of augmented reality applications in medical training
Barsom, E. Z., Graafland, M., & Schijven, M. P. (2016) · Surgical Endoscopy · doi:10.1007/s00464-016-4800-6 · Cited by 666
Berryman, D. R. (2012) · Medical Reference Services Quarterly · doi:10.1080/02763869.2012.670604 · Cited by 350
Augmented reality in healthcare education: an integrative review
Zhu, E., Hadadgar, A., Masiello, I., & Zary, N. (2014) · PeerJ · doi:10.7717/peerj.469 · Cited by 295
Towards an efficient methodology for evaluation of quality of experience in Augmented Reality
Puig, J., Perkis, A., Lindseth, F., & Ebrahimi, T. (2012) · 2012 Fourth International Workshop on Quality of Multimedia Experience · doi:10.1109/qomex.2012.6263864 · Cited by 17
Metadata
- Authors
- Botden, S. M. B. I., & Jakimowicz, J. J.
- Venue
- Surgical Endoscopy
- Published
- 2008-09-24
- Volume
- 23
- Issue
- 8
- Pages
- 1693-1700
- ISSN
- 0930-2794 (ISSN-L)
- 1432-2218
- OpenAlex
- W2128148678
- Cited by
- 190
- References
- 0
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: What is going on in augmented reality simulation in laparoscopic surgery? https://app.cochat.ai/papers/10.1007/s00464-008-0144-1
- The paper
- Botden, S. M. B. I., & Jakimowicz, J. J. (2009). What is going on in augmented reality simulation in laparoscopic surgery? Surgical Endoscopy. https://doi.org/10.1007/s00464-008-0144-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.