Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 541

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

The value of haptic feedback in conventional and robot-assisted minimal invasive surgery and virtual reality training: a current review

Open access
van der Meijden, O. A. J., Schijven, M. P.·2009·Surgical Endoscopy

Abstract

BACKGROUND: Virtual reality (VR) as surgical training tool has become a state-of-the-art technique in training and teaching skills for minimally invasive surgery (MIS). Although intuitively appealing, the true benefits of haptic (VR training) platforms are unknown. Many questions about haptic feedback in the different areas of surgical skills (training) need to be answered before adding costly haptic feedback in VR simulation for MIS training. This study was designed to review the current status and value of haptic feedback in conventional and robot-assisted MIS and training by using virtual reality simulation. METHODS: A systematic review of the literature was undertaken using PubMed and MEDLINE. The following search terms were used: Haptic feedback OR Haptics OR Force feedback AND/OR Minimal Invasive Surgery AND/OR Minimal Access Surgery AND/OR Robotics AND/OR Robotic Surgery AND/OR Endoscopic Surgery AND/OR Virtual Reality AND/OR Simulation OR Surgical Training/Education. RESULTS: The results were assessed according to level of evidence as reflected by the Oxford Centre of Evidence-based Medicine Levels of Evidence. CONCLUSIONS: In the current literature, no firm consensus exists on the importance of haptic feedback in performing minimally invasive surgery. Although the majority of the results show positive assessment of the benefits of force feedback, results are ambivalent and not unanimous on the subject. Benefits are least disputed when related to surgery using robotics, because there is no haptic feedback in currently used robotics. The addition of haptics is believed to reduce surgical errors resulting from a lack of it, especially in knot tying. Little research has been performed in the area of robot-assisted endoscopic surgical training, but results seem promising. Concerning VR training, results indicate that haptic feedback is important during the early phase of psychomotor skill acquisition.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00464-008-0298-x

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Research works printed but not linked: 28

  1. Fager PJ (2004) The use of haptics in medical application. Int J Med Robotics Comput Assisted Surg 1:36–42 · doi:10.1002/rcs.4
  2. Moody L, Baber C, Arvanitis TN (2002) Objective surgical performance evaluation based on haptic feedback. Stud Health Technol Inform 85:304–310
  3. Halvorsen FH, Elle OJ, Dalinin VV, Mork BE, Sorhus V, Rotnes JS et al (2006) Virtual reality simulator training equals mechanical robotic training in improving robot-assisted basic suturing skills. Surg Endosc 20:1565–1569 · doi:10.1007/s00464-004-9270-6
  4. Aggarwal R, Tully A, Grantcharov T, Larsen CR, Miskry T, Farthing A, Darzi A (2007) Virtual reality simulation training can improve technical skills during laparoscopic salpingectomy for ectopic pregnancy. BJOG 114:656
  5. Philips B, Ball C, Sackett D, Badenoch D, Straus S, Haynes B, Dawes M (2001) Oxford Centre for Evidence-based Medicine Levels of Evidence
  6. Barczynski M, Cichon S, Konturek A, Cichon W (2006) Minimally invasive video-assisted parathyroidectomy versus open minimally invasive parathyroidectomy for a solitary parathyroid adenoma: a prospective, randomized, blinded trial. World J Surg 30:721–731 · doi:10.1007/s00268-005-0312-6
  7. Kluivers KB, Hendriks JC, Mol BW, Bongers MY, Bremer GL, De Vet HC, Vierhout ME, Brolmann HA (2007) Quality of life and surgical outcome after total laparoscopic hysterectomy versus total abdominal hysterectomy for benign disease: a randomized, controlled trial. J Minim Invasive Gynecol 14:145–152 · doi:10.1016/j.jmig.2006.08.009
  8. Staudacher C, Vignali A, Saverio DP, Elena O, Andrea T (2007) Laparoscopic vs. open total mesorectal excision in unselected patients with rectal cancer: impact on early outcome. Dis Colon Rectum 50:1324–1331 · doi:10.1007/s10350-007-0289-3
  9. Tong DK, Law WL (2007) Laparoscopic versus open right hemicolectomy for carcinoma of the colon. JSLS 11:76–80
  10. Picod G, Jambon AC, Vinatier D, Dubois P (2005) What can the operator actually feel when performing a laparoscopy? Surg Endosc 19:95–100 · doi:10.1007/s00464-003-9330-3
  11. Lamata P, Gomez EJ, Sanchez-Margallo FM, Lamata F, del Pozo F, Uson J (2006) Tissue consistency perception in laparascopy to define the level of fidelity in virtual reality simulation. Surg Endosc 20:1368–1375 · doi:10.1007/s00464-004-9269-z
  12. Lehnert M, Richter B, Beyer PA, Heller K (2006) A prospective study comparing operative time in conventional laparoscopic and robotically assisted Thal semifundoplication in children. J Pediatr Surg 41:1392–1396 · doi:10.1016/j.jpedsurg.2006.04.025
  13. Bholat OS, Haluck RS, Murray WB, Gorman PJ, Krummel TM (1999) Tactile feedback is present during minimally invasive surgery. J Am Coll Surg 198:349–355 · doi:10.1016/s1072-7515(99)00184-2
  14. Toledo L, Gossot D, Fritsch S, Revillon Y, Reboulet C (1999) Study of sustained forces and the working space of endoscopic surgery instruments. Ann Chir 53:587–597
  15. Van der Peijl AJ, Herder JL (2001) Development of 5-mm trocar laparoscopic forceps with mechanical force feedback. Proceedings of the Design Engineering Technical Conferences 2001, American Society of Mechanical Engineers, 3–12 September 2001, DETC 01, ASME Conference, Pittsburgh, PA, USA · doi:10.1115/detc2001/dac-21070
  16. Balázs M, Feussner H, Hirzinger G, Omote K, Ungeheuer A (1998) A new tool for minor-access surgery: replacing mechanical joints in laparoscopic forceps with elastic beams for improved pressure control and sensitivity. IEEE Eng Med Biol 17:45–48 · doi:10.1109/51.677168
  17. Herder JL, Horward MJ, Sjoerdsma W (1997) A laparoscopic grasper with force perception. Minim Invasive Ther Allied Technol 6:279–286 · doi:10.3109/13645709709153076
  18. Sjoerdsma W, Herder JL, Horward MJ, Jansen A, Bannenberg JJG, Grimbergen CA (1997) Force transmission of laparoscopic grasping instruments. Minim Invasive Ther Allied Technol 6:274–278 · doi:10.3109/13645709709153075
  19. Heijnsdijk EAM, Dankelman J, Gouma DJ (2002) Effectiveness of grasping and duration of clamping using laparoscopic graspers. Surg Endosc 16:1329–1331 · doi:10.1007/s00464-001-9179-2
  20. Delaney CP, Lynch AC, Senagore AJ, Fazio VW (2003) Comparison of robotically performed and traditional laparoscopic colorectal surger. Dis Colon Rectum 46:1633–1639 · doi:10.1007/bf02660768
  21. Kornprat P, Werkgartner G, Cerwenka H, Bacher H, El-Shabrawi A, Rehak P, Mischinger HJ (2006) Prospective study comparing standard and robotically assisted laparoscopic cholecystectomy. Langenbechks Arch Surg 391:216–221 · doi:10.1007/s00423-006-0046-4
  22. Badani KK, Bhandari K, Tewari A, Menon M (2005) Comparison of two-dimensional and three-dimensional suturing: is there a difference in a robotic surgery setting? J Endourol 19:1212–1215 · doi:10.1089/end.2005.19.1212
  23. Falk V, Mintz D, Grünenfelder J, Fann JI, Burdon TA (2001) Influence of three-dimensional vision on surgical telemanipulator performance. Surg Endosc 15:1282–1288 · doi:10.1007/s004640080053
  24. Byrn JC, Schluender S, Divino CM, Conrad J, Gurland B, Shlasko E, Szold A (2007) Three-dimensional imaging improves surgical performance for both novice and experienced operators using the da Vinci Robot System. Am J Surg 193:519–522 · doi:10.1016/j.amjsurg.2006.06.042
  25. Wilson MS, Middlebrook A, Sutton C, Stone R, McCloy RF (1997) MIST VR: a virtual reality trainer for laparoscopic surgery assesses performance. Ann R Coll Surg Engl 79:403–440
  26. Kim HK, Ratter DW, Srinivasan MA (2003) The Role of Simulation Fidelity in Laparoscopic Surgical Training, 6th International Medical Image Computing and Computer Assisted · doi:10.1007/978-3-540-39899-8_1
  27. Chamarra MK, Dankelman J, van den Dobbelsteen JJ, Jansen FW (2008) Force feedback and basic laparoscopic skills. Surg Endosc 22:2140–2148 · doi:10.1007/s00464-008-9937-5
  28. Jacobs S, Holzhev D, Strauss G, Burgert O, Falk V (2007) The impact of haptic learning in telemanipulator-assisted surgery. Surg Laparosc Endosc Percutan Tech 17:402–406 · doi:10.1097/sle.0b013e3180f60c23

Cited by

See all 541

Metadata

Authors
van der Meijden, O. A. J., & Schijven, M. P.
Venue
Surgical Endoscopy
Published
2009-01-01
Volume
23
Issue
6
Pages
1180-1190
ISSN
  • 0930-2794 (ISSN-L)
  • 1432-2218
OpenAlex
W2089913832
Cited by
541
References
38
FWCI
20.91
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The value of haptic feedback in conventional and robot-assisted minimal invasive surgery and virtual reality training: a current review. https://app.cochat.ai/papers/10.1007/s00464-008-0298-x
The paper
van der Meijden, O. A. J., & Schijven, M. P. (2009). The value of haptic feedback in conventional and robot-assisted minimal invasive surgery and virtual reality training: a current review. Surgical Endoscopy. https://doi.org/10.1007/s00464-008-0298-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.