The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
The effectiveness and safety of endoscopic submucosal dissection compared with endoscopic mucosal resection for early gastric cancer: a systematic review and metaanalysis
Open accessAbstract
BackgroundEndoscopic submucosal dissection (ESD) allows en bloc resection of the entire lesion, permitting a higher curative resection rate and increased quality of life by minimizing the resection size compared with that of endoscopic mucosal resection (EMR). Although ESD has been implemented at most university hospitals in Korea, potential complications of ESD such as bleeding and perforation raise doubts in the therapeutic decision on use of the ESD procedure for early gastric cancer patients and in reimbursement decision making. This systematic review aimed to address both the effectiveness and safety outcomes of ESD versus EMR for early gastric cancer.MethodsMEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials (CENTRAL), and Koreamed were searched using the primary keywords “stomach neoplasm” AND “endoscopic submucosal dissection” AND “endoscopic mucosal resection.” To assess the quality of selected studies, the methodologic approach of the Scottish Intercollegiate Guidelines Network was used. Five effectiveness-relevant and three safety-relevant outcome measures were extracted. Bibliography management and metaanalysis for each outcome were conducted using Review Manager 5.0.ResultsThree nonconcurrent cohort studies and nine retrospective cohort studies were identified. Metaanalyses showed ESD to be significantly more effective than EMR for en bloc resection (odds ratio [OR], 8.43; 95% confidence interval [CI], 5.20–13.67), complete resection (OR, 14.11; 95% CI, 10.85–18.35), curative resection (OR, 3.28; 95% CI, 1.95–5.54), and local recurrence (risk ratio [RR], 0.13; 95% CI, 0.04–0.41). Whereas intraoperative bleeding (RR, 2.16; 95% CI, 1.14–4.09), perforation risk (RR, 3.58; 95% CI, 1.95–6.55), and operation time (standard mean difference [SMD], 1.55; 95% CI, 0.74–2.37) were significantly greater for ESD, overall bleeding risk (RR, 1.22; 95% CI, 0.76–1.98) and all-cause mortality (RR, 0.65; 95% CI, 0.08–5.38) did not differ significantly between ESD and EMR.ConclusionsConsidering that bleeding risk did not differ significantly between ESD and EMR and that perforation risk usually does not lead to life-threatening disease, the effectiveness benefit of ESD can outweigh the overall harm compared with EMR on the condition that ESD is performed by experienced practitioners.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763
Endoscopic mucosal resection for treatment of early gastric cancer
Ono, H., Kondo, H., Gotoda, T., Shirao, K., Yamaguchi, H., Saito, D., Hosokawa, K., Shimoda, T., & Yoshida, S. (2001) · Gut · doi:10.1136/gut.48.2.225 · Cited by 1,547
Chung, I.-K., Lee, J. H., Lee, S. H., Kim, S., Cho, J. Y., Cho, W. Y., Hwangbo, Y., Keum, B. R., Park, J. J., Chun, H.-J., et al. (2009) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2008.09.027 · Cited by 598
Self-citationNew Endoscopic Treatment for Intramucosal Gastric Tumors Using an Insulated-Tip Diathermic Knife
Ohkuwa, M., Hosokawa, K., Boku, N., Ohtu, A., Tajiri, H., & Yoshida, S. (2001) · Endoscopy · doi:10.1055/s-2001-12805 · Cited by 400
Cited by
Smyth, E. C., Nilsson, M., Grabsch, H. I., van Grieken, N. C., & Lordick, F. (2020) · The Lancet · doi:10.1016/s0140-6736(20)31288-5 · Cited by 4,803
Endoscopic submucosal dissection: European Society of Gastrointestinal Endoscopy (ESGE) Guideline
Pimentel-Nunes, P., Dinis-Ribeiro, M., Ponchon, T., Repici, A., Vieth, M., De Ceglie, A., Amato, A., Berr, F., Bhandari, P., Bialek, A., et al. (2015) · Endoscopy · doi:10.1055/s-0034-1392882 · Cited by 1,329
Wang, F., Shen, L., Li, J., Zhou, Z., Liang, H., Zhang, X., Tang, L., Xin, Y., Jin, J., Zhang, Y., et al. (2019) · Cancer Communications · doi:10.1186/s40880-019-0349-9 · Cited by 810
Banks, M., Graham, D., Jansen, M., Gotoda, T., Coda, S., di Pietro, M., Uedo, N., Bhandari, P., Pritchard, D. M., Kuipers, E. J., et al. (2019) · Gut · doi:10.1136/gutjnl-2018-318126 · Cited by 647
Orditura, M. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i7.1635 · Cited by 623
Metadata
- Authors
- Park, Y.-M., Cho, E., Kang, H.-Y., & Kim, J.-M.
- Venue
- Surgical Endoscopy
- Published
- 2011-03-18
- Volume
- 25
- Issue
- 8
- Pages
- 2666-2677
- ISSN
- 0930-2794 (ISSN-L)
- 1432-2218
- OpenAlex
- W1966686330
- Cited by
- 383
- References
- 6
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The effectiveness and safety of endoscopic submucosal dissection compared with endoscopic mucosal resection for early gastric cancer: a systematic review and metaanalysis. https://app.cochat.ai/papers/10.1007/s00464-011-1627-z
- The paper
- Park, Y.-M., Cho, E., Kang, H.-Y., & Kim, J.-M. (2011). The effectiveness and safety of endoscopic submucosal dissection compared with endoscopic mucosal resection for early gastric cancer: a systematic review and metaanalysis. Surgical Endoscopy. https://doi.org/10.1007/s00464-011-1627-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.