Optimizing epileptic seizure recognition performance with feature scaling and dropout layers
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Epilepsy is a widespread neurological disorder characterized by recurring seizures that have a significant impact on individuals' lives. Accurately recognizing epileptic seizures is crucial for proper diagnosis and treatment. Deep learning models have shown promise in improving seizure recognition accuracy. However, optimizing their performance for this task remains challenging. This study presents a new approach to optimize epileptic seizure recognition using deep learning models. The study employed a dataset of Electroencephalography (EEG) recordings from multiple subjects and trained nine deep learning architectures with different preprocessing techniques. By combining a 1D convolutional neural network (Conv1D) with a Long Short-Term Memory (LSTM) network, we developed the Conv1D + LSTM architecture. This architecture, augmented with dropout layers, achieved an effective test accuracy of 0.993. The LSTM architecture alone achieved a slightly lower accuracy of 0.986. Additionally, the Bidirectional LSTM (BiLSTM) and Gated Recurrent Unit (GRU) architectures performed exceptionally well, with accuracies of 0.983 and 0.984, respectively. Notably, standard scaling proved to be advantageous, significantly improving the accuracy of both BiLSTM and GRU compared to MinMax scaling. These models consistently achieved high test accuracies across different percentages of Principal Component Analysis (PCA), with the best results obtained when retaining 50% and 90% of the features. Chi-square feature selection also enhanced the classification performance of BiLSTM and GRU models. The study reveals that different deep learning architectures respond differently to feature scaling, PCA, and feature selection methods. Understanding these nuances can lead to optimized models for epileptic seizure recognition, ultimately improving patient outcomes and quality of life.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Siegel, R. L., Miller, K. D., & Jemal, A. (2015) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21254 · Cited by 11,853
Beyond Accuracy, F-Score and ROC: A Family of Discriminant Measures for Performance Evaluation
Sokolova, M., Japkowicz, N., & Szpakowicz, S. (2006) · Lecture Notes in Computer Science · doi:10.1007/11941439_114 · Cited by 1,974 · cited 1×
“(10, 11, 12, 13, and 14) respectively[47]–[49]. where TP, TN, FN, and FP are truly positive, true Negative, False Negative, and False Positive numbers respectively. n is the number of classes, b z k is the model predicted value for kth class, z k : is the corresponding target value.”
Deep learning for healthcare applications based on physiological signals: A review
Faust, O., Hagiwara, Y., Hong, T. J., Lih, O. S., & Acharya, U. R. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.04.005 · Cited by 1,026 · cited 1×
“Faust et al. 2018 [14] proposed a patient-specific seizure detection method using spectrogram images.”
Epileptic Seizure Detection in EEGs Using Time–Frequency Analysis
Tzallas, A. T., Tsipouras, M. G., & Fotiadis, D. I. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2017939 · Cited by 744 · cited 1×
“Tzallas et al. [50] utilized a Fourier transform algorithm to analyze EEG signals and extracted significant features related to fractional energy.”
Detecting Hate Speech on Twitter Using a Convolution-GRU Based Deep Neural Network
Zhang, Z., Robinson, D., & Tepper, J. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-93417-4_48 · Cited by 638 · cited 1×
“GRU has been demonstrated to perform similarly to or better than LSTM on a variety of tasks, including language modeling, speech recognition, and picture captioning [3, 6, 41].”
Truong, N. D., Nguyen, A. D., Kuhlmann, L., Bonyadi, M. R., Yang, J., Ippolito, S., & Kavehei, O. (2018) · Neural Networks · doi:10.1016/j.neunet.2018.04.018 · Cited by 635
Epileptic Seizure Detection Based on EEG Signals and CNN
Zhou, M., Tian, C., Cao, R., Wang, B., Niu, Y., Hu, T., Guo, H., & Xiang, J. (2018) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2018.00095 · Cited by 483
Alickovic, E., Kevric, J., & Subasi, A. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.07.022 · Cited by 407
DWT Based Detection of Epileptic Seizure From EEG Signals Using Naive Bayes and k-NN Classifiers
Sharmila, A., & Geethanjali, P. (2016) · IEEE Access · doi:10.1109/access.2016.2585661 · Cited by 321 · cited 1×
“Sharmila [54] presented a framework based on the analysis of EEG signals using the discrete wavelet transform (DWT) method with linear and nonlinear classifiers to detect seizures.”
Epilepsy Seizure Prediction on EEG Using Common Spatial Pattern and Convolutional Neural Network
Zhang, Y., Guo, Y., Yang, P., Chen, W., & Lo, B. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2933046 · Cited by 319
Cited by
ConvNextUNet: A small-region attentioned model for cardiac MRI segmentation
Zhang, H., & Cai, Z. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108592 · Cited by 17
Metadata
- Authors
- Omar, A., & Abd El-Hafeez, T.
- Venue
- Neural Computing and Applications
- Published
- 2023-11-24
- Volume
- 36
- Issue
- 6
- Pages
- 2835-2852
- ISSN
- 0941-0643 (ISSN-L)
- 1433-3058
- OpenAlex
- W4388976757
- Cited by
- 202
- References
- 53
- FWCI
- 28.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.