The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Clinimetric evaluation of active range of motion measures in patients with non-specific neck pain: a systematic review
Open accessAbstract
The study is to provide a critical analysis of the research literature on clinimetric properties of instruments that can be used in daily practice to measure active cervical range of motion (ACROM) in patients with non-specific neck pain. A computerized literature search was performed in Medline, Cinahl and Embase from 1982 to January 2007. Two reviewers independently assessed the clinimetric properties of identified instruments using a criteria list. The search identified a total of 33 studies, investigating three different types of measurement instruments to determine ACROM. These instruments were: (1) different types of goniometers/inclinometers, (2) visual estimation, and (3) tape measurements. Intra- and inter-observer reliability was demonstrated for the cervical range of motion instrument (CROM), Cybex electronic digital instrument (EDI-320) and a single inclinometer. The presence of agreement was assessed for the EDI-320 and a single inclinometer. The CROM received a positive rating for construct validity. When clinical acceptability is taken into account both the CROM and the single inclinometer can be considered appropriate instruments for measuring the active range of motion in patients with non-specific neck pain in daily practice. Reliability is the aspect most frequently evaluated. Agreement, validity and responsiveness are documented less frequently.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quality criteria were proposed for measurement properties of health status questionnaires
Terwee, C. B., Bot, S. D. M., de Boer, M. R., van der Windt, D. A. W. M., Knol, D. L., Dekker, J., Bouter, L. M., & de Vet, H. C. W. (2007) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2006.03.012 · Cited by 10,764
Evaluating patient-based outcome measures for use in clinical trials.
Fitzpatrick, Davey, Buxton, & Jones (1998) · Health Technology Assessment · doi:10.3310/hta2140 · Cited by 1,715 · cited 4×
“Assigning value labels for ranges of Kappa and ICC statistics and correlation coefficients was done in accordance with other authors [29, 43, 66, 67].”
BackgroundMethodResultInfluentialThe prevalence of neck pain in the world population: a systematic critical review of the literature
Fejer, R., Kyvik, K. O., & Hartvigsen, J. (2006) · European Spine Journal · doi:10.1007/s00586-004-0864-4 · Cited by 1,195
Reliability: what is it, and how is it measured?
Bruton, A., Conway, J. H., & Holgate, S. T. (2000) · Physiotherapy · doi:10.1016/s0031-9406(05)61211-4 · Cited by 763 · cited 1×
“the same measurement procedure in daily practice [13].”
Method
Cited by
Validity and Between-Day Reliability of the Cervical Range of Motion (CROM) Device
Audette, I., Dumas, J.-P., Côté, J. N., & De Serres, S. J. (2010) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2010.3180 · Cited by 396
Metadata
- Authors
- de Koning, C. H. P., van den Heuvel, S. P., Staal, J. B., Smits-Engelsman, B. C. M., & Hendriks, E. J. M.
- Venue
- European Spine Journal
- Published
- 2008-04-22
- Volume
- 17
- Issue
- 7
- Pages
- 905-921
- ISSN
- 0940-6719 (ISSN-L)
- 1432-0932
- OpenAlex
- W1994681183
- Cited by
- 179
- References
- 4
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.