CoChat

Prospective clinical study of a novel biodegradable sub-acromial spacer in treatment of massive irreparable rotator cuff tears

Senekovic, Vladimir, Poberaj, Boris, Kovacic, Ladislav, Mikek, Martin, Adar, Eliyahu, Dekel, Assaf · 2013 · European Journal of Orthopaedic Surgery & Traumatology

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

Purpose The purposes of this prospective non-randomized study were to confirm the feasibility of the biodegradable sub-acromial spacer (InSpace™) implantation in patients with massive irreparable rotator cuff tear and to determine the safety profile and functional results 3 years post-implantation.Methods Twenty patients were implanted with the InSpace™ device and assessed up to 3 years of post-implantation. Improvement in shoulder function was assessed using Constant score, while ease of use of the system was recorded by surgeons as were device-related adverse events.Results Twenty patients were available for assessment. Implantation was performed arthroscopically in all patients, and a range of deployment time was 2-20 min. The mean total Constant score increased from 33.4 to 65.4 points at 3 years. There was an improvement of 6.4 points in subjective pain score which commenced at 1 week post-operatively and was sustained until 3 years of follow-up. Also activities of daily living and motions commenced improvement by 9.4 and 7.7 points, respectively. Improvement in power was only evident at 18 months of follow-up but was sustained at 3 years.Conclusions Arthroscopic deployment of a co-polymer biodegradable spacer (balloon) into the sub-acromial space for an irreparable rotator cuff tear was found to be low-risk and simple procedure associated with improvement in shoulder function and low rate of complications.Level of evidence IV; therapeutic case series.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00590-012-0981-4

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Cited by

See all 161

Metadata

Authors
Senekovic, V., Poberaj, B., Kovacic, L., Mikek, M., Adar, E., & Dekel, A.
Affiliations
  • Orthopaedic Hospital Valdoltra (SI)
  • Wolfson Medical Center (IL)
  • Assuta Medical Center (IL)
Corresponding author
Dekel, Assaf
Venue
European Journal of Orthopaedic Surgery & Traumatology
Published
2012-04-12
Volume
23
Issue
3
Pages
311-316
ISSN
  • 0948-4817 (ISSN-L)
  • 1633-8065
  • 1432-1068
OpenAlex
W2090455148
Cited by
154
References
23
Citations by year
2026: 10 · 2025: 4 · 2024: 12 · 2023: 22 · 2022: 12 · 2021: 12 · 2020: 14 · 2019: 21 · 2018: 16 · 2017: 8 · 2016: 11 · 2015: 3 · 2014: 6 · 2013: 3
FWCI
3.91
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • European Journal of Orthopaedic Surgery & Traumatology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Shoulder Injury and Treatment
  • Health Sciences › Medicine › Surgery › Orthopedic Surgery and Rehabilitation
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Tendon Structure and Treatment
Keywords
massive irreparable rotator cuff tear, arthroscopic implantation, shoulder function, Constant score, shoulder pain, implant safety
MeSH terms
Rotator Cuff Injuries, Acromion, Aged, Aged, 80 and over, Female, Humans, Joint Prosthesis, Male, Middle Aged, Prospective Studies, Shoulder Joint, Shoulder Impingement Syndrome, Arthroplasty, Replacement, Shoulder Pain, Absorbable Implants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.