Novel paper-based potentiometric combined sensors using coumarin derivatives modified with vanadium pentoxide nanoparticles for the selective determination of trace levels of lead ions
The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Novel miniaturized Pb(II) paper-based potentiometric sensors are described using coumarin derivatives I and II as electroactive ionophores and nano vanadium pentoxide as a solid contact material for the sensitive and selective monitoring of trace lead ions. Density functional theory (DFT) confirms optimum geometries, electronic properties, and charge transfer behaviors of 1:2 Pb(II): coumarin complexes. The sensors are prepared by using two strips of 20 × 5 mm filter paper with two circular orifices. One orifice is coated with vanadium pentoxide (V 2 O 5) nanoparticles in colloidal conductive carbon as a solid-contact, covered by a PVC membrane containing coumarin ionophore to act as a sensing probe. The other orifice is treated with Ag/AgCl in a polyvinyl butyral (PVB) film, to act as a reference electrode. Sensors with ionophores (I) and (II) exhibit Nernstian slopes of 27.7 ± 0.2 and 30.2 ± 0.2 mV/decade over the linear concentration range 4.5 × 10-7 to 6.2 × 10-3 M and 8.5 × 10-8 to 6.2 × 10-3 M, with detection limits of 1.3 × 10-7 M (26.9 ppb) and 2.1 × 10-8 M (4.4 ppb), respectively. The sensors are satisfactorily used for accurate determination of lead ions in drinking water, lead-acid battery wastewater, and electronic waste leachates. The results compare favourably well with data obtained by flameless atomic absorption spectrometry.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recent advances in environmental monitoring, such as paper-based sensors for trace lead ion detection in battery waste streams [143], highlight the growing synergy between battery health management and recycling technologies.”
From The State of Health Estimation of Lithium-Ion Batteries: A Review of Health Indicators, Estimation Methods, Development Trends and Challenges (2025) · cites this paper as [143]
Citations
Cites
Standard methods: For the examination of water and waste water
(1990) · Analytical Biochemistry · doi:10.1016/0003-2697(90)90598-4 · Cited by 72,091
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 1×
“On the other hand, the most commonly used substrates are ceramic [31], polyethylene terephthalate (PET) [32], polydimethylsiloxane (PDMS) [33], textile [34], and paper [35].”
Encyclopedia of analytical science
(1996) · Choice Reviews Online · doi:10.5860/choice.33-3645 · Cited by 738
Bobacka, J. (1999) · Analytical Chemistry · doi:10.1021/ac990497z · Cited by 686 · cited 1×
“4 and 5 [57]. where ΔE, I, R b , Δt, and C represent the potential change, applied current (1 nA), bulk membrane resistance, time variation and redox capacitance, respectively.”
You, H., Mu, Z., Zhao, M., Zhou, J., Chen, Y., & Bai, L. (2019) · Microchimica Acta · doi:10.1007/s00604-018-3127-5 · Cited by 592
Bioactive paper provides a low-cost platform for diagnostics
Pelton, R. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.05.005 · Cited by 562
Ion-Selective Electrodes Using Carbon Nanotubes as Ion-to-Electron Transducers
Crespo, G. A., Macho, S., & Rius, F. X. (2008) · Analytical Chemistry · doi:10.1021/ac071156l · Cited by 425
Toxicological Profile for Lead
(2002) · ATSDR's Toxicological Profiles · doi:10.1201/9781420061888_ch106 · Cited by 382
Reuben, A., Caspi, A., Belsky, D. W., Broadbent, J., Harrington, H., Sugden, K., Houts, R. M., Ramrakha, S., Poulton, R., & Moffitt, T. E. (2017) · JAMA · doi:10.1001/jama.2017.1712 · Cited by 328
A critical review on cellulose: From fundamental to an approach on sensor technology
Ummartyotin, S., & Manuspiya, H. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.08.050 · Cited by 327
Research works printed but not linked: 2
- Organization WH (2022) Lead in drinking-water: health risks, monitoring and corrective actions: technical brief. Geneva, Switzerland
- Govindarajan D, Uma Shankar V, Gopalakrishnan R (2019) Supercapacitor behavior and characterization of RGO anchored V2O5 nanorods. J Mater Sci: Mater Electron 30:16142–16155
Cited by
Next-Generation Potentiometric Sensors: A Review of Flexible and Wearable Technologies
Fathy, M. A., & Bühlmann, P. (2025) · Biosensors · doi:10.3390/bios15010051 · Cited by 86
Tang, K., Luo, B., Chen, D., Wang, C., Chen, L., Li, F., Cao, Y., & Wang, C. (2025) · World Electric Vehicle Journal · doi:10.3390/wevj16080429 · Cited by 68
Hassan, S. S. M., & Fathy, M. A. (2024) · Microchimica Acta · doi:10.1007/s00604-024-06802-6 · Cited by 14
Advancements in Electrochemical Sensors for Detection of Environmental Pollutants: A Review
Sharma, E., Singh, A. K., Singh, K., Ganti, S. S., Gupta, G. D., & Verma, S. K. (2025) · Electrocatalysis · doi:10.1007/s12678-025-00962-6 · Cited by 21
“Sensors with ionophores (I) and (II) show Nernstian slopes of 27.7 ± 0.2 and 30.2 ± 0.2 mV/ decade over the linear concentration range 4.5 × 10 −7 to 6.2 × 10 −3 M and 8.5 × 10 −8 to 6.2 × 10 −3 M, with detection limits of 1.3 × 10 −7 M (26.9 ppb) and 2.1 × 10 −8 M (4.4 ppb), respectively [50].”
InfluentialAn Overview of Lithium-Ion Battery Recycling: A Comparison of Brazilian and International Scenarios
Furlanetto, J., de Lara, M. V. C., Simionato, M., do Nascimento, V., & Telli, G. D. (2025) · World Electric Vehicle Journal · doi:10.3390/wevj16070371 · Cited by 10
“Therefore, it is also important to detect and measure this harmful substance in the environment [32].”
Wang, H., Huo, G., Xu, G., Yu, D., Liu, S., & Wang, Q. (2025) · Polymers · doi:10.3390/polym17212941 · Cited by 8
A novel solid-state iodide ion-selective electrode based on copper-doped MgB2 superconductor
Hassan, S. S. M., & Fathy, M. A. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.115639 · Cited by 4
Tang, Y., Li, G. S., Lu, Z., Wang, Y., Liu, W., Jing, G., Liu, W., Yu, J., & Li, W. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.118047 · Cited by 3
Sun, J., Fan, D., Zhang, H., Dong, Y., Liu, J., Li, G., Yang, M., Wang, X., Yuan, R., Zhou, B., et al. (2025) · RSC Advances · doi:10.1039/d5ra07199b · Cited by 2
Kanberoğlu, G. S., Kaya, N., & Ağırtaş, M. S. (2025) · Next research. · doi:10.1016/j.nexres.2025.101287 · Cited by 3
Hassan, S. S. M., & Fathy, M. A. (2026) · Polymers · doi:10.3390/polym18040492 · Cited by 2
“Over the past decades, three primary classes of solid-contact materials have been investigated: (i) carbon-based materials [35], (ii) conducting polymers [36], and (iii) hybrid https://doi.org/10.3390/polym18040492 Polymers 2026 , 18 , 492 or composite materials [37].”
InfluentialWardak, C., Grabarczyk, M., Suljkanović, M., Suljagić, J., & Wardak, M. (2025) · ChemPhysChem · doi:10.1002/cphc.202500500 · Cited by 1
Ferrari, A., Ratel, S., Berthoin, S., Garnier, J.-P., & Baquet, G. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1809119 · Cited by 1
Wei, R., Shang, L., Zhang, W., Li, X., Jia, L., Ma, R.-N., & Wang, H. (2025) · Molecules · doi:10.3390/molecules30091951
“Lead ions (Pb 2+ ), a persistent and bioaccumulative environmental toxin, pose profound and irreversible health consequences for humans [1–3].”
Zhang, S., Li, D., Huang, J., Liu, W., Jing, G., Liu, W., Yu, J., Song, T., & Li, W. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.116001
Shen, T., Xie, X., Xu, C., & Wu, S. (2025) · Symmetry · doi:10.3390/sym18010024
Graphene–carbon dot–Ti 3 C 2 MXene–V 2 O 5 hybrid sensor for the detection of lead in seawater
Musthafa, T., Muhamed, A. P., & Gopika, R. (2026) · Materials Advances · doi:10.1039/d6ma00401f
Godja, N., Kitzmantel, M., & Munteanu, F. (2026) · Recycling · doi:10.3390/recycling11100176
Metadata
- Authors
- Hassan, S. S. M., & Fathy, M. A.
- Affiliations
- Ain Shams University (EG)
- Corresponding author
- Hassan, Saad S. M.
- Fathy, Mahmoud Abdelwahab
- Venue
- Microchimica Acta
- Published
- 2024-06-27
- Volume
- 191
- Issue
- 7
- Pages
- 427-427
- ISSN
- 0026-3672 (ISSN-L)
- 1436-5073
- OpenAlex
- W4400092467
- Cited by
- 18
- References
- 59
- Citations by year
- 2026: 5 · 2025: 12 · 2024: 1
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Microchimica Acta (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Keywords
- lead ion detection, coumarins, vanadium pentoxide nanoparticles, solid-contact ion-selective electrodes, Nernstian response, trace metal analysis, drinking water, filter paper sensor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.