CoChat

Novel paper-based potentiometric combined sensors using coumarin derivatives modified with vanadium pentoxide nanoparticles for the selective determination of trace levels of lead ions

Hassan, Saad S. M., Fathy, Mahmoud Abdelwahab · 2024 · Microchimica Acta

The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.

Abstract

Novel miniaturized Pb(II) paper-based potentiometric sensors are described using coumarin derivatives I and II as electroactive ionophores and nano vanadium pentoxide as a solid contact material for the sensitive and selective monitoring of trace lead ions. Density functional theory (DFT) confirms optimum geometries, electronic properties, and charge transfer behaviors of 1:2 Pb(II): coumarin complexes. The sensors are prepared by using two strips of 20 × 5 mm filter paper with two circular orifices. One orifice is coated with vanadium pentoxide (V 2 O 5) nanoparticles in colloidal conductive carbon as a solid-contact, covered by a PVC membrane containing coumarin ionophore to act as a sensing probe. The other orifice is treated with Ag/AgCl in a polyvinyl butyral (PVB) film, to act as a reference electrode. Sensors with ionophores (I) and (II) exhibit Nernstian slopes of 27.7 ± 0.2 and 30.2 ± 0.2 mV/decade over the linear concentration range 4.5 × 10-7 to 6.2 × 10-3 M and 8.5 × 10-8 to 6.2 × 10-3 M, with detection limits of 1.3 × 10-7 M (26.9 ppb) and 2.1 × 10-8 M (4.4 ppb), respectively. The sensors are satisfactorily used for accurate determination of lead ions in drinking water, lead-acid battery wastewater, and electronic waste leachates. The results compare favourably well with data obtained by flameless atomic absorption spectrometry.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00604-024-06494-y

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 59 references

Research works printed but not linked: 2

  1. Organization WH (2022) Lead in drinking-water: health risks, monitoring and corrective actions: technical brief. Geneva, Switzerland
  2. Govindarajan D, Uma Shankar V, Gopalakrishnan R (2019) Supercapacitor behavior and characterization of RGO anchored V2O5 nanorods. J Mater Sci: Mater Electron 30:16142–16155

Cited by

Metadata

Authors
Hassan, S. S. M., & Fathy, M. A.
Affiliations
Ain Shams University (EG)
Corresponding author
  • Hassan, Saad S. M.
  • Fathy, Mahmoud Abdelwahab
Venue
Microchimica Acta
Published
2024-06-27
Volume
191
Issue
7
Pages
427-427
ISSN
  • 0026-3672 (ISSN-L)
  • 1436-5073
OpenAlex
W4400092467
Cited by
18
References
59
Citations by year
2026: 5 · 2025: 12 · 2024: 1
FWCI
2.79
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • Microchimica Acta (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
Keywords
lead ion detection, coumarins, vanadium pentoxide nanoparticles, solid-contact ion-selective electrodes, Nernstian response, trace metal analysis, drinking water, filter paper sensor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.