Novel paper-based potentiometric combined sensors using coumarin derivatives modified with vanadium pentoxide nanoparticles for the selective determination of trace levels of lead ions
The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Novel miniaturized Pb(II) paper-based potentiometric sensors are described using coumarin derivatives I and II as electroactive ionophores and nano vanadium pentoxide as a solid contact material for the sensitive and selective monitoring of trace lead ions. Density functional theory (DFT) confirms optimum geometries, electronic properties, and charge transfer behaviors of 1:2 Pb(II): coumarin complexes. The sensors are prepared by using two strips of 20 × 5 mm filter paper with two circular orifices. One orifice is coated with vanadium pentoxide (V 2 O 5) nanoparticles in colloidal conductive carbon as a solid-contact, covered by a PVC membrane containing coumarin ionophore to act as a sensing probe. The other orifice is treated with Ag/AgCl in a polyvinyl butyral (PVB) film, to act as a reference electrode. Sensors with ionophores (I) and (II) exhibit Nernstian slopes of 27.7 ± 0.2 and 30.2 ± 0.2 mV/decade over the linear concentration range 4.5 × 10-7 to 6.2 × 10-3 M and 8.5 × 10-8 to 6.2 × 10-3 M, with detection limits of 1.3 × 10-7 M (26.9 ppb) and 2.1 × 10-8 M (4.4 ppb), respectively. The sensors are satisfactorily used for accurate determination of lead ions in drinking water, lead-acid battery wastewater, and electronic waste leachates. The results compare favourably well with data obtained by flameless atomic absorption spectrometry.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recent advances in environmental monitoring, such as paper-based sensors for trace lead ion detection in battery waste streams [143], highlight the growing synergy between battery health management and recycling technologies.”
From The State of Health Estimation of Lithium-Ion Batteries: A Review of Health Indicators, Estimation Methods, Development Trends and Challenges (2025) · cites this paper as [143]
Citations
Cites
Standard methods: For the examination of water and waste water
(1990) · Analytical Biochemistry · doi:10.1016/0003-2697(90)90598-4 · Cited by 72,091
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 1×
“On the other hand, the most commonly used substrates are ceramic [31], polyethylene terephthalate (PET) [32], polydimethylsiloxane (PDMS) [33], textile [34], and paper [35].”
Encyclopedia of analytical science
(1996) · Choice Reviews Online · doi:10.5860/choice.33-3645 · Cited by 738
Bobacka, J. (1999) · Analytical Chemistry · doi:10.1021/ac990497z · Cited by 686 · cited 1×
“4 and 5 [57]. where ΔE, I, R b , Δt, and C represent the potential change, applied current (1 nA), bulk membrane resistance, time variation and redox capacitance, respectively.”
You, H., Mu, Z., Zhao, M., Zhou, J., Chen, Y., & Bai, L. (2019) · Microchimica Acta · doi:10.1007/s00604-018-3127-5 · Cited by 592
Bioactive paper provides a low-cost platform for diagnostics
Pelton, R. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.05.005 · Cited by 562
Ion-Selective Electrodes Using Carbon Nanotubes as Ion-to-Electron Transducers
Crespo, G. A., Macho, S., & Rius, F. X. (2008) · Analytical Chemistry · doi:10.1021/ac071156l · Cited by 425
Toxicological Profile for Lead
(2002) · ATSDR's Toxicological Profiles · doi:10.1201/9781420061888_ch106 · Cited by 382
Reuben, A., Caspi, A., Belsky, D. W., Broadbent, J., Harrington, H., Sugden, K., Houts, R. M., Ramrakha, S., Poulton, R., & Moffitt, T. E. (2017) · JAMA · doi:10.1001/jama.2017.1712 · Cited by 328
A critical review on cellulose: From fundamental to an approach on sensor technology
Ummartyotin, S., & Manuspiya, H. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.08.050 · Cited by 327
Quality control criteria for solid-contact, solvent polymeric membrane ion-selective electrodes
Lindner, E., & Gyurcsányi, R. E. (2009) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-008-0608-1 · Cited by 320
Gupta, V. K., Jain, A. K., & Kumar, P. (2006) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.02.019 · Cited by 317
A Textile‐Based Stretchable Multi‐Ion Potentiometric Sensor
Parrilla, M., Cánovas, R., Jeerapan, I., Andrade, F. J., & Wang, J. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600092 · Cited by 269 · cited 1×
“On the other hand, the most commonly used substrates are ceramic [31], polyethylene terephthalate (PET) [32], polydimethylsiloxane (PDMS) [33], textile [34], and paper [35].”
Bakker, E. (1996) · Journal of The Electrochemical Society · doi:10.1149/1.1836608 · Cited by 205
A low-cost flexible pH sensor array for wound assessment
Rahimi, R., Ochoa, M., Parupudi, T., Zhao, X., Yazdi, I. K., Dokmeci, M. R., Tamayol, A., Khademhosseini, A., & Ziaie, B. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.12.082 · Cited by 205
Agency for Toxic Substances and Disease Registry (ATSDR)
(2016) · Pollution Control Handbook for Oil and Gas Engineering · doi:10.1002/9781119117896.ch1 · Cited by 199
Powell, K. J., Brown, P. L., Byrne, R. H., Gajda, T., Hefter, G., Leuz, A.-K., Sjöberg, S., & Wanner, H. (2009) · Pure and Applied Chemistry · doi:10.1351/pac-rep-09-03-05 · Cited by 169
Lead-induced increase in antioxidant enzymes and lipid peroxidation products in developing rat brain
Bokara, K. K., Brown, E. T., McCormick, R., Yallapragada, P. R., Rajanna, S., & Rajanna, B. (2007) · BioMetals · doi:10.1007/s10534-007-9088-5 · Cited by 135
Wang, L., Li, B., Wang, J., Qi, J., Li, J., Ma, J., & Chen, L. (2022) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.128165 · Cited by 109
Some alkylphosphoric acid esters for use in coated-wire calcium-selective electrodes
Cattrall, R. W., Drew, D. M., & Hamilton, I. C. (1975) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)85398-8 · Cited by 108
Lee, Y., Jang, K., Ma, Y., Koh, A., Chen, H., Jung, H. N., Kim, Y., Kwak, J. W., Wang, L., Xue, Y., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605476 · Cited by 99
Bakker, E., Willer, M., Lerchi, M., Seiler, K., & Pretsch, E. (1994) · Analytical Chemistry · doi:10.1021/ac00076a016 · Cited by 92
Das, S., Roy, A., Barui, A. K., Alabbasi, M. M. A., Kuncha, M., Sistla, R., Sreedhar, B., & Patra, C. R. (2020) · Nanoscale · doi:10.1039/d0nr00631a · Cited by 90
Calcium-selective electrodes with pvc membranes and solid internal contacts
Hulanicki, A., & Trojanowicz, M. (1976) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)82269-8 · Cited by 86
Temam, A. G., Alshoaibi, A. A., Getaneh, S. A., Awada, C., Nwanya, A. C., Ejikeme, P. M., & Ezema, F. I. (2023) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2023.101239 · Cited by 86
Lead Interaction with Human Protamine (HP2) as a Mechanism of Male Reproductive Toxicity
Quintanilla‐Vega, B., Hoover, D. J., Bal, W., Silbergeld, E. K., Waalkes, M. P., & Anderson, L. D., Jr. (2000) · Chemical Research in Toxicology · doi:10.1021/tx000017v · Cited by 83
Zhou, X., Wu, G., Wu, J., Yang, H., Wang, J., Gao, G., Cai, R., & Yan, Q. (2013) · Journal of Materials Chemistry A · doi:10.1039/c3ta13143b · Cited by 81
Potentiometric sensor for non invasive lactate determination in human sweat
Onor, M., Gufoni, S., Lomonaco, T., Ghimenti, S., Salvo, P., Sorrentino, F., & Bramanti, E. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.07.050 · Cited by 73
Lisak, G. (2021) · Environmental Pollution · doi:10.1016/j.envpol.2021.117882 · Cited by 73
Carbon Black-Modified Electrodes Screen-Printed onto Paper Towel, Waxed Paper and Parafilm M®
Cinti, S., Mazzaracchio, V., Cacciotti, I., Moscone, D., & Arduini, F. (2017) · Sensors · doi:10.3390/s17102267 · Cited by 69
Hassan, S. S. M. (2003) · Talanta · doi:10.1016/s0039-9140(03)00038-9 · Cited by 67
Rasheed, R. T., Mansoor, H. S., Abdullah, T. A., Juzsakova, T., Aljammal, N., Salman, A. D., Al-Shaikhly, R. R., Le, P., Domokos, E., & Abdulla, T. A. (2020) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-020-09725-5 · Cited by 67
Flexible copper-biopolymer nanocomposite sensors for trace level lead detection in water
Pathak, P., Hwang, J.-H., Li, R. H. T., Rodriguez, K. L., Rex, M. M., Lee, W. H., & Cho, H. J. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.130263 · Cited by 60
Liu, J., Chen, H., Mao, X., & Jin, X. (2000) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067310008034135 · Cited by 57
Zhang, W., Zhang, H., Li, J., Zou, X., Wang, W., Hu, H., Iqbal, K., Zhou, P., & Ye, W. (2023) · Microchimica Acta · doi:10.1007/s00604-023-06047-9 · Cited by 50
Liu, C., Jiang, X., Zhao, Y., Jiang, W., Zhang, Z., & Yu, L. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.01.162 · Cited by 49
Pseudocapacitive porous amorphous vanadium pentoxide with enhanced multicolored electrochromism
Wang, J., Zhao, W., Tam, B., Zhang, H., Zhou, Y., Li, Y., & Cheng, W. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.139655 · Cited by 47
Screen‐Printed Carbon Electrodes
Fletcher, S. (2015) · Advances in electrochemical science and engineering · doi:10.1002/9783527697489.ch12 · Cited by 46
Hassan, S. S. M., Kamel, A. H., & Fathy, M. A. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.340239 · Cited by 41
Huang, Z., Song, H., Feng, L., Qin, J., Wang, Q., Guo, B., Wei, L., Lu, Y., Guo, H., Zhu, D., et al. (2022) · Microchemical Journal · doi:10.1016/j.microc.2022.108346 · Cited by 40
Ligand exchange spectrophotometric method for the determination of mole ratio in metal complexes
Mansour, F. R., & Danielson, N. D. (2012) · Microchemical Journal · doi:10.1016/j.microc.2012.01.008 · Cited by 37
Hassan, S. S. M., Kamel, A. H., & Fathy, M. A. (2022) · Talanta · doi:10.1016/j.talanta.2022.123907 · Cited by 36
Mir, M., Lugo, R., Tahirbegi, I. B., & Samitier, J. (2014) · Sensors · doi:10.3390/s140711844 · Cited by 31
Kumar, S., Mittal, S. K., Kaur, N., & Kaur, R. (2017) · RSC Advances · doi:10.1039/c7ra00393e · Cited by 28
Javorac, D., Djordjević, A. B., Anđelković, M., Tatović, S., Baralić, K., Miljaković, E. A., Kotur‐Stevuljević, J., Đukić-Ćosić, D., Antonijević, B., & Bulat, Z. (2020) · Archives of Industrial Hygiene and Toxicology · doi:10.2478/aiht-2020-71-3425 · Cited by 28
Akkaya, E., Erulaş, F. A., Büyükpınar, Ç., & Bakırdere, S. (2019) · Food Chemistry · doi:10.1016/j.foodchem.2019.06.014 · Cited by 27
Hassan, S. S. M., Kamel, A. H., Amr, A. E. E., Fathy, M. A., & Al-Omar, M. A. (2020) · Molecules · doi:10.3390/molecules25030629 · Cited by 26
Li, Y., Li, J., & Qin, W. (2022) · Talanta · doi:10.1016/j.talanta.2022.123797 · Cited by 22
Hassan, S. S. M., Abdelbasir, S. M., Fathy, M. A., Amr, A. E. E., Al-Omar, M. A., & Kamel, A. H. (2019) · Nanomaterials · doi:10.3390/nano9081160 · Cited by 19
ÇETİN, Z., & Dede, B. (2023) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2023.121636 · Cited by 19
Yağmuroğlu, O. (2023) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2023.105164 · Cited by 18
Şanlıer, Ş., & Aydın, A. (2022) · Marine Pollution Bulletin · doi:10.1016/j.marpolbul.2022.113787 · Cited by 17
Gouda, M. A. S., Salem, M. A. I., Marzouk, M. I., Mahmoud, N. F. H., & Ismail, M. F. (2023) · Chemistry & Biodiversity · doi:10.1002/cbdv.202300706 · Cited by 16
Hassan, S. S. M., Kamel, A. H., Amr, A. E. E., Abd‐Rabboh, H. S. M., Al-Omar, M. A., & Elsayed, E. A. (2020) · Molecules · doi:10.3390/molecules25133076 · Cited by 15
Mechanochemical activation for lead extraction from spent cathode ray tube
Fathy, M. A., Abdelbasir, S. M., Hassan, S. S. M., Kamel, A. H., & Rayan, D. A. (2021) · Journal of Material Cycles and Waste Management · doi:10.1007/s10163-021-01198-4 · Cited by 15
Grotti, M., Vecchio, M. A., Gobbato, D., Mataloni, M., & Ardini, F. (2023) · Journal of Analytical Atomic Spectrometry · doi:10.1039/d2ja00424k · Cited by 15
Hassan, S. S. M., Fathy, M. A., Moussa, I., Obaida, M., & Kamel, A. H. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.133397 · Cited by 14
Kataba, A., Nakayama, S. M. M., Nakata, H., Toyomaki, H., Yohannes, Y. B., Yabe, J., Muzandu, K. M., Zyambo, G., Kubota, A., Matsukawa, T., et al. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18020767 · Cited by 13
Shagri, L. M. S. A., Kamel, A. H., Abd‐Rabboh, H. S. M., & Bajaber, M. A. (2022) · ACS Omega · doi:10.1021/acsomega.2c02250 · Cited by 6
Research works printed but not linked: 2
- Organization WH (2022) Lead in drinking-water: health risks, monitoring and corrective actions: technical brief. Geneva, Switzerland
- Govindarajan D, Uma Shankar V, Gopalakrishnan R (2019) Supercapacitor behavior and characterization of RGO anchored V2O5 nanorods. J Mater Sci: Mater Electron 30:16142–16155
Cited by
Next-Generation Potentiometric Sensors: A Review of Flexible and Wearable Technologies
Fathy, M. A., & Bühlmann, P. (2025) · Biosensors · doi:10.3390/bios15010051 · Cited by 86
Tang, K., Luo, B., Chen, D., Wang, C., Chen, L., Li, F., Cao, Y., & Wang, C. (2025) · World Electric Vehicle Journal · doi:10.3390/wevj16080429 · Cited by 68
Hassan, S. S. M., & Fathy, M. A. (2024) · Microchimica Acta · doi:10.1007/s00604-024-06802-6 · Cited by 14
Advancements in Electrochemical Sensors for Detection of Environmental Pollutants: A Review
Sharma, E., Singh, A. K., Singh, K., Ganti, S. S., Gupta, G. D., & Verma, S. K. (2025) · Electrocatalysis · doi:10.1007/s12678-025-00962-6 · Cited by 21
“Sensors with ionophores (I) and (II) show Nernstian slopes of 27.7 ± 0.2 and 30.2 ± 0.2 mV/ decade over the linear concentration range 4.5 × 10 −7 to 6.2 × 10 −3 M and 8.5 × 10 −8 to 6.2 × 10 −3 M, with detection limits of 1.3 × 10 −7 M (26.9 ppb) and 2.1 × 10 −8 M (4.4 ppb), respectively [50].”
InfluentialAn Overview of Lithium-Ion Battery Recycling: A Comparison of Brazilian and International Scenarios
Furlanetto, J., de Lara, M. V. C., Simionato, M., do Nascimento, V., & Telli, G. D. (2025) · World Electric Vehicle Journal · doi:10.3390/wevj16070371 · Cited by 10
“Therefore, it is also important to detect and measure this harmful substance in the environment [32].”
Metadata
- Authors
- Hassan, S. S. M., & Fathy, M. A.
- Affiliations
- Ain Shams University (EG)
- Corresponding author
- Hassan, Saad S. M.
- Fathy, Mahmoud Abdelwahab
- Venue
- Microchimica Acta
- Published
- 2024-06-27
- Volume
- 191
- Issue
- 7
- Pages
- 427-427
- ISSN
- 0026-3672 (ISSN-L)
- 1436-5073
- OpenAlex
- W4400092467
- Cited by
- 18
- References
- 59
- Citations by year
- 2026: 5 · 2025: 12 · 2024: 1
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Microchimica Acta (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Keywords
- lead ion detection, coumarins, vanadium pentoxide nanoparticles, solid-contact ion-selective electrodes, Nernstian response, trace metal analysis, drinking water, filter paper sensor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.