Vagus nerve stimulation lead removal or replacement: surgical technique, institutional experience, and literature overview
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: With the growing use of vagus nerve stimulation (VNS) as a treatment for refractory epilepsy, there is a growing demand for complete removal or replacement of the VNS system. We evaluate the safety and efficacy of complete removal or replacement of the VNS system and provide an extensive description of our surgical technique. METHODS: We retrospectively reviewed our patient registry for all VNS surgeries performed between January 2007 (the year of our first complete removal) and May 2014. In order to assess patient satisfaction, a written questionnaire was sent to patients or their caregivers. Additionally, we reviewed all literature on this topic. RESULTS: The VNS system was completely removed in 22 patients and completely replaced in 13 patients. There were no incomplete removals. Revision surgery was complicated by a small laceration of the jugular vein in two patients and by vocal cord paralysis in one patient. Seizure frequency was unaltered or improved after revision surgery. Electrode-related side effects all improved after revision surgery. Twenty-one studies reported a total of 131 patients in whom the VNS system was completely removed. In 95 patients, the system was subsequently replaced. The most frequently reported side effect was vocal cord paresis, which occurred in four patients. CONCLUSIONS: Complete removal or replacement of the VNS system including lead and coils is feasible and safe. Although initial results seem promising, further research and longer follow-up are needed to assess whether lead replacement may affect VNS effectiveness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vagus nerve stimulation, side effects, and long-term safety
Ben-Menachem, E. (2001) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200109000-00005 · Cited by 400 · cited 1×
“The treatment is generally well tolerated and severe side effects are rare [4, 13, 15, 26].”
BackgroundBen‐Menachem, E., Revesz, D., Simon, B. J., & Silberstein, S. (2015) · European Journal of Neurology · doi:10.1111/ene.12629 · Cited by 344
Complete removal of vagus nerve stimulator generator and electrodes: Technical note
Ortler, M., Unterhofer, C., Dobesberger, J., Haberlandt, E., & Trinka, E. (2010) · Journal of Neurosurgery: Pediatrics · doi:10.3171/2009.9.peds0810 · Cited by 22 · cited 2×
“Similarly, a patient’s age does not affect the feasibility of lead revision [19].”
Background
Cited by
Morphing electronics enable neuromodulation in growing tissue
Liu, Y., Li, J., Song, S., Kang, J., Tsao, Y., Chen, S., Mottini, V., McConnell, K., Xu, W., Zheng, Y.-Q., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0495-2 · Cited by 325
Toffa, D. H., Touma, L., El Meskine, T., Bouthillier, A., & Nguyen, D. K. (2020) · Seizure · doi:10.1016/j.seizure.2020.09.027 · Cited by 286
Vagus nerve stimulation: Surgical technique of implantation and revision and related morbidity
Giordano, F., Zicca, A., Barba, C., Guerrini, R., & Genitori, L. (2017) · Epilepsia · doi:10.1111/epi.13678 · Cited by 258
“Anyway, only a few patients manifested a permanent vocal cord palsy (<1%).(37,49) In the series by Ng, eight patients underwent lead revision through ultrasharp low-voltage cautery coupled with blunt dissection without any damage to the vagus nerve and any related complication.”
BackgroundInfluential
Metadata
- Authors
- Aalbers, M. W., Rijkers, K., Klinkenberg, S., Majoie, M., & Cornips, E. M. J.
- Venue
- Acta Neurochirurgica
- Published
- 2015-09-03
- Volume
- 157
- Issue
- 11
- Pages
- 1917-1924
- ISSN
- 0001-6268 (ISSN-L)
- 0942-0940
- OpenAlex
- W2131457259
- Cited by
- 50
- References
- 3
- FWCI
- 1.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vagus nerve stimulation lead removal or replacement: surgical technique, institutional experience, and literature overview. https://app.cochat.ai/papers/10.1007/s00701-015-2547-9
- The paper
- Aalbers, M. W., Rijkers, K., Klinkenberg, S., Majoie, M., & Cornips, E. M. J. (2015). Vagus nerve stimulation lead removal or replacement: surgical technique, institutional experience, and literature overview. Acta Neurochirurgica. https://doi.org/10.1007/s00701-015-2547-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.