Complete removal of vagus nerve stimulator generator and electrodes: Technical note
Abstract
Vagus nerve stimulation has become widely used in the palliative treatment of refractory epilepsy. Removal of a vagus nerve stimulator may be desirable or even necessary due to lack of efficacy, intolerable side effects, signs of infection, or failure of the device. Unless the lead or the helical electrodes are defective, only the generator is explanted and the electrodes are usually left behind for fear of damaging nerve or surrounding structures. The authors review their experience with complete removal of the stimulating electrodes and pacemaker-like generator device in 9 consecutive patients, 3 of whom were children. Using microsurgical techniques, the authors were able to completely remove the stimulator, including electrodes in all patients. All nerves remained morphologically intact. One case of temporary and one of permanent clinically silent ipsilateral vocal cord paresis were observed.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Several adverse reactions caused by these drawbacks have been reported clinically, such as vomiting, cough, and difficulty in breathing in VNS therapy.
“Several adverse reactions caused by these drawbacks have been reported clinically, such as vomiting, cough, and difficulty in breathing in VNS therapy (18, 19).”
From Climbing-inspired twining electrodes using shape memory for peripheral nerve stimulation and recording (2019) · cites this paper as [19]
Cites
Vagus-nerve stimulation for the treatment of epilepsy
Ben-Menachem, E. (2002) · The Lancet Neurology · doi:10.1016/s1474-4422(02)00220-x · Cited by 560 · see citing works
Schachter, S. C., & Saper, C. B. (1998) · Epilepsia · doi:10.1111/j.1528-1157.1998.tb01151.x · Cited by 373 · see citing works
Rutecki, P. A. (1990) · Epilepsia · doi:10.1111/j.1528-1157.1990.tb05843.x · Cited by 341 · see citing works
Amar, A. P., Heck, C., Levy, M. L., Thomas, S., DeGiorgio, C. M., Oviedo, S., & Apuzzo, M. L. J. (1998) · Neurosurgery · doi:10.1097/00006123-199812000-00001 · Cited by 174 · see citing works
Complications of chronic vagus nerve stimulation for epilepsy in children
Smyth, M. D., Tubbs, R. S., Bebin, E. M., Grabb, P. A., & Blount, J. P. (2003) · Journal of neurosurgery · doi:10.3171/jns.2003.99.3.0500 · Cited by 162 · see citing works
Surgical Technique for Implantation of the Neurocybernetic Prosthesis
Reid, S. A. (1990) · Epilepsia · doi:10.1111/j.1528-1157.1990.tb05847.x · Cited by 143 · see citing works
Efficacy and Safety of Vagus Nerve Stimulation in Patients With Complex Partial Seizures
Uthman, B. M., Wilder, B. J., Hammond, E. J., & Reid, S. A. (1990) · Epilepsia · doi:10.1111/j.1528-1157.1990.tb05849.x · Cited by 131 · see citing works
Vagus nerve stimulation for epilepsy: a review
Binnie, C. D. (2000) · Seizure · doi:10.1053/seiz.1999.0354 · Cited by 112 · see citing works
Vagus nerve stimulation for complex partial seizures: surgical technique, safety, and efficacy
Landy, H. J., Ramsay, R. E., Slater, J. D., Casiano, R. R., & Morgan, R. O. (1993) · Journal of neurosurgery · doi:10.3171/jns.1993.78.1.0026 · Cited by 110 · see citing works
Vagus nerve stimulation: predictors of seizure freedom
Janszky, J. (2005) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.2004.037085 · Cited by 95 · see citing works
The Implantable Neurocybernetic Prosthesis System
Terry, R. S., Tarver, W. B., & Zabara, J. (1991) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1991.tb04052.x · Cited by 92 · see citing works
Complications of vagal nerve stimulation for epilepsy in children
Rychlicki, F., Zamponi, N., Cesaroni, E., Corpaci, L., Trignani, R., Ducati, A., & Scerrati, M. (2006) · Neurosurgical Review · doi:10.1007/s10143-005-0005-5 · Cited by 80 · see citing works
Espinosa, J. A., Aiello, M. T., & Naritoku, D. K. (1999) · Surgical Neurology · doi:10.1016/s0090-3019(99)00046-4 · Cited by 74 · see citing works
Revision of vagal nerve stimulator electrodes: technical approach
MacDonald, J. D., & Couldwell, W. T. (2004) · Acta Neurochirurgica · doi:10.1007/s00701-004-0246-z · Cited by 41 · see citing works
Ortler, M., Luef, G., Kofler, A., Bauer, G., & Twerdy, K. (2001) · Epilepsia · doi:10.1046/j.1528-1157.2001.23800.x · Cited by 34 · see citing works
Self-citationDelayed onset of vocal cord paralysis after explantation of a vagus nerve stimulator in a child
Vassilyadi, M., & Strawsburg, R. H. (2003) · Child s Nervous System · doi:10.1007/s00381-003-0722-4 · Cited by 31 · see citing works
Self-inflicted vocal cord paralysis in two patients with vagus nerve stimulators
Kalkanis, J. G., Krishna, P. D., Espinosa, J. A., & Naritoku, D. K. (2002) · Journal of neurosurgery · doi:10.3171/jns.2002.96.5.0949 · Cited by 29 · see citing works
Schachter, S. C. (2004) · doi:10.1002/9780470752463.ch73 · Cited by 8 · see citing works
Surgical technique in vagus nerve stimulation
Kemeny, A. A. (2002) · CRC Press eBooks · doi:10.3109/9780203627105-3 · Cited by 7 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Zhang, Y., Zheng, N., Cao, Y., Wang, F., Wang, P., Ma, Y., Lu, B., Hou, G., Fang, Z., Liang, Z., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw1066 · Cited by 314 · see citing works
“Several adverse reactions caused by these drawbacks have been reported clinically, such as vomiting, cough, and difficulty in breathing in VNS therapy (18, 19).”
BackgroundVagus nerve stimulation: Surgical technique of implantation and revision and related morbidity
Giordano, F., Zicca, A., Barba, C., Guerrini, R., & Genitori, L. (2017) · Epilepsia · doi:10.1111/epi.13678 · Cited by 258 · see citing works
Aalbers, M. W., Rijkers, K., Klinkenberg, S., Majoie, M., & Cornips, E. M. J. (2015) · Acta Neurochirurgica · doi:10.1007/s00701-015-2547-9 · Cited by 50 · see citing works
“Similarly, a patient’s age does not affect the feasibility of lead revision [19].”
BackgroundBiomechanical and functional variation in rat sciatic nerve following cuff electrode implantation
Restaino, S. M., Abliz, E., Wachrathit, K., Krauthamer, V., & Shah, S. B. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-73 · Cited by 44 · see citing works
“clinical implantations of vagal nerve stimulators have shown significant mechanical impact including tensile and compressive loading [67-70] as well as functional changes such as vocal function, voice alteration, dyspnea, coughing and aspiration [24, 25, 46].”
BackgroundVagus nerve stimulation in patients with Lennox‐Gastaut syndrome: A meta‐analysis
Dibué, M., Greco, T., Spoor, J. K. H., Tahir, Z., Specchio, N., Hänggi, D., Steiger, H., & Kamp, M. A. (2020) · Acta Neurologica Scandinavica · doi:10.1111/ane.13375 · Cited by 43 · see citing works
Clark, A., Kuperman, R. A., Auguste, K. I., & Sun, P. P. (2012) · Journal of Neurosurgery Pediatrics · doi:10.3171/2011.12.peds11124 · Cited by 29 · see citing works
Rozman, J., Pečlin, P., Ribarič, S., Godec, M., & Burja, J. (2018) · Scientific Reports · doi:10.1038/s41598-018-19318-w · Cited by 11 · see citing works
Vagal Nerve Stimulation: Indications for Revision in Adult Refractory Epilepsy
Gigliotti, M. J., Mao, G., Dupré, D. A., & Wilberger, J. E. (2018) · World Neurosurgery · doi:10.1016/j.wneu.2018.09.008 · Cited by 11 · see citing works
O’Neill, B. R., & Wilberger, J. E. (2010) · Operative Neurosurgery · doi:10.1227/neu.0b013e3181f825a3 · Cited by 11 · see citing works
“Although some reports have shown that lead removal and replacement through an anterior triangle approach is possible in some cases, vocal cord paralysis has been reported with complete removal of spiral electrodes.(1,2,7) Our approach has been to leave the dysfunctional spiral electrodes on the nerve to avoid unnecess…”
BackgroundHamdi, H., Spatola, G., Lagarde, S., McGonigal, A., Paz-Paredes, A., Alain, B., Bartoloméi, F., & Carron, R. (2019) · Operative Neurosurgery · doi:10.1093/ons/opz227 · Cited by 11 · see citing works
Hasegawa, H., Gompel, J. J. V., Marsh, W. R., Wharen, R. E., Zimmerman, R. S., Burkholder, D. B., Lundstrom, B. N., Britton, J. W., & Meyer, F. B. (2020) · Journal of neurosurgery · doi:10.3171/2020.7.jns201385 · Cited by 8 · see citing works
Successful removal and reimplant of vagal nerve stimulator device after 10 years
Giulioni, M., Martinoni, M., Naldi, I., Bisulli, F., Pozzati, E., & Tinuper, P. (2012) · Annals of Indian Academy of Neurology · doi:10.4103/0972-2327.94997 · Cited by 7 · see citing works
“In literature, only a few papers have reported about this condition, and to our knowledge, this is the first case of a complete removal and replacement of VNS after 10 years.[6-8] In accordance with the method described by MacDonald and W.”
Kumar, R., Winston, K. R., & Folzenlogen, Z. A. (2016) · World Neurosurgery · doi:10.1016/j.wneu.2016.03.085 · Cited by 7 · see citing works
Yuan, Y., Hao, H., Wen, X., Mo, X., & Li, L. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610959 · Cited by 3 · see citing works
Noris, A., Roncon, P., Peraio, S., Zicca, A., Lenge, M., Rita, A. D., Genitori, L., & Giordano, F. (2021) · Journal of Neurosurgery Case Lessons · doi:10.3171/case21128 · Cited by 1 · see citing works
Neuroprothetik und Funktionelle Elektrostimulation
(2010) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2010.715 · Cited by 1 · see citing works
Saba, E. S., & Rivero, A. (2023) · International Journal of Pediatric Otorhinolaryngology · doi:10.1016/j.ijporl.2023.111603 · Cited by 1 · see citing works
Non-resective Epilepsy Surgery
Zentner, J. (2020) · Springer eBooks · doi:10.1007/978-3-030-48748-5_14 · Cited by 1 · see citing works
Zentner, J. (2020) · Springer eBooks · doi:10.1007/978-3-030-48748-5_15 · Cited by 1 · see citing works
Connock, M. J., & Moore, D. (2011)
Analysis of the use of vagus nerve stimulator in the treatment of epilepsy
Terra, E. C., Souza, J. V. R. E., Santiago, D. D. P., Passos, G. F., Moreira, E. D. M., Garcia, M. R., Lisboa, J. B., Medeiros, A. P. A. D. S., de Barros, G. H. A., Filho, P. A. C. D. S., et al. (2024) · Contribuciones a las Ciencias Sociales · doi:10.55905/revconv.17n.8-034
Patel, A., & Rajgopal, B. (2026) · Current Medical Research and Opinion · doi:10.1080/03007995.2026.2723579
“Complete explantation or revision with device replacement is indicated when there is device mal-function (reported in 4–16.8% of cases), lack of therapeutic benefit from VNS, unacceptable adverse effects, or at the patient’s request 58,59 .”
Influential
- Authors
- Ortler, M., Unterhofer, C., Dobesberger, J., Haberlandt, E., & Trinka, E.
- Affiliations
- Innsbruck Medical University (AT)
- Clinical Departments of Neurosurgery
- Neurology, and
- Corresponding author
- Ortler, Martin
- Venue
- Journal of Neurosurgery: Pediatrics
- Published
- 2010-02
- Volume
- 5
- Issue
- 2
- Pages
- 191-194
- ISSN
- 1933-0707 (ISSN-L)
- 1933-0715
- OpenAlex
- W1504000282
- Cited by
- 22
- References
- 19
- Citations by year
- 2026: 1 · 2024: 1 · 2023: 1 · 2021: 1 · 2020: 4 · 2019: 2 · 2018: 2 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 1 · 2013: 1 · 2012: 2
- FWCI
- 1.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Neurosurgery Pediatrics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Health Sciences › Medicine › Neurology › Neurological disorders and treatments
- Health Sciences › Medicine › Psychiatry and Mental health › Epilepsy research and treatment
- Keywords
- vagus nerve stimulation, electrode removal, helical electrodes, microsurgical technique, drug-resistant epilepsy, pediatric epilepsy, vocal cord paresis, nerve injury
- MeSH terms
- Adolescent, Adult, Child, Preschool, Electrodes, Implanted, Electric Stimulation Therapy, Epilepsy, Female, Humans, Male, Microsurgery, Postoperative Complications, Vagus Nerve, Vocal Cord Paralysis, Neurosurgical Procedures, Device Removal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review