The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Innovative antimicrobial coating of titanium implants with iodine
Open accessAbstract
BACKGROUND: Postoperative infection associated with implants remains a serious complication in orthopedic surgery. Several biomaterial surface treatments have been proposed as a means of reducing the incidence of implant-associated infections. In this study, a clinical trial was performed using an iodine-supported titanium that suppresses the microbial activities. METHODS: A total of 222 patients with postoperative infection or compromised status were treated using iodine-supported titanium implants. The mean age of the patients was 49.4 years (range 5-85 years). One hundred twenty-seven patients were male and 95 were female. In 158 patients, iodine-supported implants were used to prevent infection, such as compromised hosts and conditions, and in 64 patients to treat active infection. White blood cell (WBCs) and C-reactive protein (CRP) levels were measured pre- and postoperatively in all patients. To confirm whether iodine from the implant affected physiological functions, thyroid hormone levels in the blood were examined. Both examinations were conducted sequentially for a year. Radiological evaluations were performed regularly after the operation. The chronological changes of the iodine amount were evaluated using half pins removed after completion of external fixation. RESULTS: The mean follow-up period was 18.4 months (range 3-44 months). Acute infection developed in three tumor cases among the 158 patients on preventive therapy. All three recovered without removal of the implants. Infection was cured in all 64 patients with infection. Median WBC levels were in the normal range, and median CRP levels returned to <0.5 within 4 weeks after surgery. Abnormalities of thyroid gland function were not detected. None of the patients experienced loosening of the implants. There were two patients with mechanical implant failure, which was treated by re-implantation. Excellent bone ingrowth and ongrowth were found around all hip and tumor prostheses. One year later, the amount of iodine on external fixation pins remained about 20-30%. CONCLUSIONS: Iodine-supported titanium implants can be very effective for preventing and treating infections after orthopedic surgery. Cytotoxicity and adverse effects were not detected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevention of pin tract infection with titanium‐copper alloys
Shirai, T., Tsuchiya, H., Shimizu, T., Ohtani, K., Zen, Y., & Tomita, K. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31412 · Cited by 199
Self-citation
Cited by
Antibacterial titanium surfaces for medical implants
Ferraris, S., & Spriano, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.12.062 · Cited by 424
Romanò, C. L., Scarponi, S., Gallazzi, E., Romanò, D., & Drago, L. (2015) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-015-0294-5 · Cited by 311
Quinn, J., McFadden, R., Chan, C.-W., & Carson, L. (2020) · iScience · doi:10.1016/j.isci.2020.101745 · Cited by 285
Metadata
- Authors
- Tsuchiya, H., Shirai, T., Nishida, H., Murakami, H., Kabata, T., Yamamoto, N., Watanabe, K., & Nakase, J.
- Venue
- Journal of Orthopaedic Science
- Publisher
- Elsevier BV
- Published
- 2012-09
- Volume
- 17
- Issue
- 5
- Pages
- 595-604
- ISSN
- 0949-2658 (ISSN-L)
- OpenAlex
- W2034118322
- Cited by
- 197
- References
- 1
- FWCI
- 12.93
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Innovative antimicrobial coating of titanium implants with iodine. https://app.cochat.ai/papers/10.1007/s00776-012-0247-3
- The paper
- Tsuchiya, H., Shirai, T., Nishida, H., Murakami, H., Kabata, T., Yamamoto, N., Watanabe, K., & Nakase, J. (2012). Innovative antimicrobial coating of titanium implants with iodine. Journal of Orthopaedic Science. https://doi.org/10.1007/s00776-012-0247-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.