Abnormal Umbilical Cord Coiling is Associated with Adverse Perinatal Outcomes
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
The normal umbilical cord coil index is one coil/5 cm, i.e., 0.2 ±0.1 coils completed per cm. We report the frequency and clinical correlations of abnormally coiled cords among 1329 cases referred to our placental pathology services. Twenty-one percent of cords were over-coiled and 13% were undercoiled. Abnormal cord coiling was seen at all gestational ages. Principal clinical correlations found in overcoiled cords were fetal demise (37%), fetal intolerance to labor (14%), intrauterine growth retardation (10%), and chorioamnionitis (10%). For undercoiled cords, the frequencies of these adverse outcomes were 29%, 21%, 15%, and 29%, respectively. Abnormal cord coiling was associated with thrombosis of chorionic plate vessels, umbilical venous thrombosis, and cord stenosis. Thus, abnormal cord coiling is a chronic state, established in early gestation, that may have chronic (growth retardation) and acute (fetal intolerance to labor and fetal demise) effects on fetal well-being. The cause of abnormal cord coiling is not known. Its effects on neurological status of survivors are also unknown. Antenatal detection of abnormal cord coil index by ultrasound could lead to elective delivery of fetuses at risk, thereby reducing the fetal death rate by about one-half. We recommend that the cord coil index become part of the routine placental pathology examination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mutation in blood coagulation factor V associated with resistance to activated protein C
Bertina, R. M., Koeleman, B. P. C., Koster, T., Rosendaal, F. R., Dirven, R. J., de Ronde, H., van der Velden, P. A., & Reitsma, P. H. (1994) · Nature · doi:10.1038/369064a0 · Cited by 3,783
Pathology of the Human Placenta
Benirschke, K., & Kaufmann, P. (1995) · Springer eBooks · doi:10.1007/978-1-4757-4196-4 · Cited by 381
Strong, T. H., Jarles, D. L., Vega, J. S., & Feldman, D. B. (1994) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(13)70274-6 · Cited by 251
Stillbirth evaluation: What tests are needed?
Incerpi, M. H., Miller, D. A. W., Samadi, R., Settlage, R. H., & Goodwin, T. M. (1998) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(98)70311-4 · Cited by 148 · cited 1×
“In a recent survey [ 21 ] of stillbirths from 1990 to 1994 in one institution, 36% remained unexplained even after thorough evaluation and testing (not including cord coil index).”
BackgroundAdverse perinatal outcome in patients with an abnormal umbilical coiling index
RANA, J., EBERT, G., & KAPPY, K. (1995) · Obstetrics & Gynecology · doi:10.1016/0029-7844(94)00435-g · Cited by 134 · cited 6×
“Strong et al. [6] 0.21 0.07 100 consecutive births Degani et al. [8] 0.28 0.08 45 consecutive births Degani et al. [8] 0.44 0.11 Prenatal, same cases Rana et al. [ 9 ] 0.19 0.10 635 consecutive births Ercal et al. [11] 0.20 0.10 147 consecutive births”
BackgroundResultInfluentialNon-Coiled Umbilical Blood Vessels: A New Marker for the Fetus at Risk
Strong, T. H., Elliott, J. P., & Radin, T. G. (1993) · Journal of diagnostic medical sonography · doi:10.1177/875647939300900338 · Cited by 124
Sonographic estimation of umbilical coiling index and correlation with doppler flow characteristics
Degani, S., MLEWINSKY, R., Berger, H. M., & SPIEGEL, D. (1995) · Obstetrics and Gynecology · doi:10.1016/0029-7844(95)00307-d · Cited by 107 · cited 5×
“The reported normal cord coil index is one coil/5 cm, or 0.2 6 0.1 (1 SD) coils per cm [6, 8 ,9,11] (Table 1). There is an approximately normal distribution of cord coil index in these series, but all show a more pronounced tail on the OCC side of the distribution curve.”
BackgroundResultInfluentialPathology of the Placenta. 2nd ed.
Parkash, V. (2000) · The American Journal of Surgical Pathology · doi:10.1097/00000478-200002000-00019 · Cited by 76
UMBILICAL COILING INDEX: IS IT A MARKER FOR THE FOETUS AT RISK?
Erçal, T., Laçin, S., Altunyurt, S., Saygılı, U., Cinar, O., & Mumcu, A. (1996) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.1996.tb09545.x · Cited by 57
Antepartum diagnosis of noncoiled umbilical cords
Strong, T. H., Finberg, H. J., & Mattox, J. H. (1994) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(94)70348-5 · Cited by 45
Cited by
Clinical and pathological umbilical cord abnormalities in fetal thrombotic vasculopathy
Redline, R. W. (2004) · Human Pathology · doi:10.1016/j.humpath.2004.08.003 · Cited by 172
Pathak, S., Hook, E., Hackett, G., Murdoch, E., Sebire, N. J., Jessop, F., & Lees, C. (2010) · Placenta · doi:10.1016/j.placenta.2010.08.004 · Cited by 72
Pathophysiological significance of abnormal umbilical cord coiling index
Sebire, N. J. (2007) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5180 · Cited by 40
Metadata
- Authors
- Machin, G. A., Ackerman, J., & Gilbert-Barness, E.
- Venue
- Pediatric and Developmental Pathology
- Publisher
- SAGE Publications
- Published
- 2000-09
- Volume
- 3
- Issue
- 5
- Pages
- 462-471
- ISSN
- 1093-5266 (ISSN-L)
- 1615-5742
- OpenAlex
- W2079480366
- Cited by
- 233
- References
- 14
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Abnormal Umbilical Cord Coiling is Associated with Adverse Perinatal Outcomes. https://app.cochat.ai/papers/10.1007/s100240010103
- The paper
- Machin, G. A., Ackerman, J., & Gilbert-Barness, E. (2000). Abnormal Umbilical Cord Coiling is Associated with Adverse Perinatal Outcomes. Pediatric and Developmental Pathology. https://doi.org/10.1007/s100240010103
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.