Adverse perinatal outcome in patients with an abnormal umbilical coiling index
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To evaluate perinatal outcome in neonates with hypocoiled and hypercoiled cords. METHODS: From February 18 through June 13, 1994, 635 placentas from deliveries of at least 24 weeks' gestation were examined for umbilical coiling. The umbilical coiling index was calculated by dividing the total number of coils by the length of the cord. Subjects with umbilical coiling indices below the tenth percentile, above the 90th percentile, and between the tenth and 90th percentiles were defined as hypocoiled, hypercoiled, and normocoiled, respectively. Subjects with hypocoiled and hypercoiled cords were compared with those found to have normocoiled cords. Twelve different characteristics were used to measure perinatal outcome. RESULTS: The subjects with hypocoiled cords differed from those with normocoiled cords in two significant ways: rates of fetal heart rate (FHR) disturbances and interventional delivery were higher in the hypocoiled group (28.6 versus 15.9% [P = .01] and 19 versus 7.1% [P = .002], respectively). The subjects with hypercoiled cords compared with those found to have normocoiled cords had a higher rate of premature delivery (33.3 versus 12.0% [P < .0001] and a higher incidence of cocaine use (12.7 versus 3.3% [P = .0006]). CONCLUSION: Hypocoiled cords can be predictors of potential interventional delivery and intrapartum FHR disturbances. Hypercoiled cords are associated with an increased incidence of premature delivery and maternal cocaine use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Abnormal Umbilical Cord Coiling is Associated with Adverse Perinatal Outcomes
Machin, G. A., Ackerman, J., & Gilbert-Barness, E. (2000) · Pediatric and Developmental Pathology · doi:10.1007/s100240010103 · Cited by 233
“Strong et al. [6] 0.21 0.07 100 consecutive births Degani et al. [8] 0.28 0.08 45 consecutive births Degani et al. [8] 0.44 0.11 Prenatal, same cases Rana et al. [ 9 ] 0.19 0.10 635 consecutive births Ercal et al. [11] 0.20 0.10 147 consecutive births”
BackgroundResultInfluentialPathophysiological significance of abnormal umbilical cord coiling index
Sebire, N. J. (2007) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5180 · Cited by 40
Ultrasound screening of umbilical cord abnormalities and delivery management
Hasegawa, J. (2018) · Placenta · doi:10.1016/j.placenta.2017.12.003 · Cited by 40
Pradipta, G. A., Wardoyo, R., Musdholifah, A., & Sanjaya, I. N. H. (2022) · Health Informatics Journal · doi:10.1177/14604582221084211 · Cited by 9
Metadata
- Authors
- RANA, J., EBERT, G., & KAPPY, K.
- Venue
- Obstetrics & Gynecology
- Published
- 1995-04
- Volume
- 85
- Issue
- 4
- Pages
- 573-577
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W2079183489
- Cited by
- 134
- References
- 0
- FWCI
- 3.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adverse perinatal outcome in patients with an abnormal umbilical coiling index. https://app.cochat.ai/papers/10.1016/0029-7844(94)00435-g
- The paper
- RANA, J., EBERT, G., & KAPPY, K. (1995). Adverse perinatal outcome in patients with an abnormal umbilical coiling index. Obstetrics & Gynecology. https://doi.org/10.1016/0029-7844(94)00435-g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.