Application of a Real-Time Polymerase Chain Reaction with Internal Positive Control for Detection and Quantification of Enterovirus in Cerebrospinal Fluid
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A quantitative real-time reverse transcriptase-polymerase chain reaction (RT-PCR) method based on TaqMan technology was developed to determine the presence and amount of enterovirus RNA. In order to prevent false-negative results, a one-step multiplex RT-PCR was optimized. It contains two dual-labelled fluorogenic probes to quantify the 5′ noncoding region of enterovirus and detect an internal positive control. In the present study, 104 cerebrospinal fluid samples collected during an outbreak of enteroviral meningitis were analyzed using this method. Amplification of the internal positive control was effective in all but two specimens, confirming the absence of PCR inhibitors and allowing the results of amplification to be validated. The sensitivity of the RT-PCR was 96.8%, while that of cell culture was 34.9%. Genomic viral loads found ranged between 3.3 and 5.9 log10 copies per milliliter of cerebrospinal fluid (mean, 4.8 log10 copies/ml). This fluorogenic enterovirus RT-PCR allows large numbers of samples to be screened rapidly. Moreover, its sensitivity and reproducibility make it highly reliable. With these characteristics, the enterovirus RT-PCR can be a useful tool that may offer considerable benefit in the clinical management of patients with enteroviral infections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SAWYER, M. H., HOLLAND, D., AINTABLIAN, N., CONNOR, J. D., KEYSER, E. F., & WAECKER, N. J. (1994) · The Pediatric Infectious Disease Journal · doi:10.1097/00006454-199403000-00002 · Cited by 171
Cited by
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R., et al. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.165-256.2006 · Cited by 1,318
Real-time PCR in the microbiology laboratory
Mackay, I. M. (2004) · Clinical Microbiology and Infection · doi:10.1111/j.1198-743x.2004.00722.x · Cited by 807
Real-time reverse transcription PCR (qRT-PCR) and its potential use in clinical diagnosis
Bustin, S. A., & Mueller, R. (2005) · Clinical Science · doi:10.1042/cs20050086 · Cited by 529
Detection and monitoring of virus infections by real-time PCR
Watzinger, F., Ebner, K., & Lion, T. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.001 · Cited by 281
Molecular Methods for Diagnosis of Viral Encephalitis
DeBiasi, R. L., & Tyler, K. L. (2004) · Clinical Microbiology Reviews · doi:10.1128/cmr.17.4.903-925.2004 · Cited by 274
Metadata
- Authors
- S., M., M., C.-B., M., C.-M., B., B., J., C., S., B., & V., F.
- Venue
- European Journal of Clinical Microbiology & Infectious Diseases
- Published
- 2002-07-01
- Volume
- 21
- Issue
- 7
- Pages
- 532-536
- ISSN
- 0934-9723 (ISSN-L)
- 1435-4373
- OpenAlex
- W1978490576
- Cited by
- 72
- References
- 1
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.