Adaptive blind interaction technique for touchscreens
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Most work on non-visual text-entry for people with visual impairments has focused on the comparison of input techniques reporting on performance measures, such as accuracy and speed.”
From Typing Performance of Blind Users (2015) · cites this paper as [28]
Citations
Cites
Phrase sets for evaluating text entry techniques
MacKenzie, I. S., & Soukoreff, R. W. (2003) · CHI '03 extended abstracts on Human factors in computing systems - CHI '03 · doi:10.1145/765891.765971 · Cited by 825
Tactons: structured tactile messages for non-visual information display
Brewster, S. A., & Brown, L. M. (2004) · Enlighten: Publications (University of Glasgow) · Cited by 697
A morphological analysis of the design space of input devices
Card, S. K., Mackinlay, J. D., & Robertson, G. G. (1991) · ACM Transactions on Information Systems · doi:10.1145/123078.128726 · Cited by 337 · cited 1×
“time also helps to develop new ways of interaction for visually handicapped users the main problem of which is absolute spatial pointing and selection of the menu items within a screen space [6, 7, 24].”
BackgroundPartridge, K., Chatterjee, S., Sazawal, V., Borriello, G., & Want, R. (2002) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/571985.572013 · Cited by 149
T-Cube: a fast, self-disclosing pen-based alphabet
Venolia, D., & Neiberg, F. (1994) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/191666.191761 · Cited by 107
Adaptive one-switch row-column scanning
Simpson, R. C., & Koester, H. H. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808950 · Cited by 107
A study of blind drawing practice: creating graphical information without the visual channel
Kamel, H. M., & Landay, J. A. (2000) · International ACM SIGACCESS Conference on Computers and Accessibility (ASSETS) · doi:10.1145/354324.354334 · Cited by 79
A system for fast, full-text entry for small electronic devices
Nesbat, S. B. (2003) · INTERNATIONAL CONFERENCE ON MULTIMODAL INTERACTION · doi:10.1145/958432.958437 · Cited by 70
Performance of menu-augmented soft keyboards
Isokoski, P. (2004) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/985692.985746 · Cited by 56
Use of Audio-Haptic Interface Techniques to Allow Nonvisual Access to Touchscreen Appliances
Vanderheiden, G. C. (1996) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/154193129604002430 · Cited by 54
Human Computer Interaction: Issues and Challenges
Chen, Q. (2000) · IGI Global eBooks · doi:10.4018/978-1-87828-991-9 · Cited by 53
Analysing mouse and pen flick gestures
Moyle, M., & Cockburn, A. (2002) · doi:10.1145/2181216.2181220 · Cited by 23
Rönnberg, J., Samuelsson, E., & Borg, E. (2002) · International Journal of Audiology · doi:10.3109/14992020209090404 · Cited by 18
Gedrics: The Next Generation of Icons
Geiβler, J. (1995) · IFIP advances in information and communication technology · doi:10.1007/978-1-5041-2896-4_12 · Cited by 15
Two Characters per Stroke - A Novel Pen-Based Text Input Technique
Jhaveri, N. (2003) · Cited by 8
(2003) · Institutional Repositories DataBase (IRDB)
Research works printed but not linked: 5
- Bourhis G, Pino P (2003) Temporal analysis of the use of an augmentative communication device. In: Proceedings of AAATE’03. IOS Press, Netherlands, pp 294–298
- Callahan J, Hopkins D, Weiser M, Shneiderman B (1988) A comparative analysis of pie menu performance. In: Proceedings of CHI’88 conference, Washington DC. Web site (2004) http://www.catalog.com/hopkins/piemenus/callahan.ps
- Evreinov G, Raisamo R (2002) Tactile pointer for touchscreen manipulations. In: Proceedings of HANDICAP 2002. L’Institut Federativf de Recherche sur les Aides Techniques pour Personnes Handicapees, Paris, pp 115–120
- Lesher GW, Higginbotham DJ, Moulton BJ (2000) Techniques for automatically updating scanning delays. In: Proceedings of the RESNA 2000, pp 85–87
- Stephanidis C, Savidis A (2001) Interface development toolkits for non-visual and switch-based interaction. In: Proceedings of ERCIM News, Special Theme. Human Computer Interaction 46:4–15
Cited by
Kane, S. K., Bigham, J. P., & Wobbrock, J. O. (2008) · Proceedings of the 10th International ACM SIGACCESS Conference on Computers and Accessibility · doi:10.1145/1414471.1414487 · Cited by 374
“Systems developed by Sánchez and Aguayo [15] and Yfantidis and Evreinov [20] allow users to enter text on touch screens using multi-tap and directional gestures, respectively, and provide audio feedback as the user types.”
BackgroundUsable gestures for blind people: understanding preference and performance
Kane, S. K., Wobbrock, J. O., & Ladner, R. E. (2011) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1978942.1979001 · Cited by 314
No-Look Notes: Accessible Eyes-Free Multi-touch Text Entry
Bonner, M. N., Brudvik, J. T., Abowd, G. D., & Edwards, W. K. (2010) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-12654-3_24 · Cited by 154
Exploring the use of speech input by blind people on mobile devices
Azenkot, S., & Lee, N. B. (2013) · Proceedings of the 15th International ACM SIGACCESS Conference on Computers and Accessibility · doi:10.1145/2513383.2513440 · Cited by 151
Access overlays: improving non-visual access to large touch screens for blind users
Kane, S. K., Morris, M. R., Perkins, A. Z., Wigdor, D., Ladner, R. E., & Wobbrock, J. O. (2011) · Proceedings of the 24th annual ACM symposium on User interface software and technology · doi:10.1145/2047196.2047232 · Cited by 127
“Researchers have also explored techniques to address specific aspects of blind touch screen interaction, such as text entry [3,10,36] and gesture selection [18].”
Background
Metadata
- Authors
- Yfantidis, G., & Evreinov, G.
- Affiliations
- Tampere University (FI)
- Corresponding author
- Yfantidis, Georgios
- ORCID
- Evreinov, Grigori
- Venue
- Universal Access in the Information Society
- Published
- 2005-07-09
- Volume
- 4
- Issue
- 4
- Pages
- 328-337
- ISSN
- 1615-5289 (ISSN-L)
- 1615-5297
- OpenAlex
- W2160843249
- Cited by
- 73
- References
- 16
- Citations by year
- 2025: 1 · 2024: 4 · 2023: 4 · 2022: 2 · 2019: 5 · 2018: 4 · 2017: 7 · 2016: 2 · 2015: 4 · 2014: 7 · 2013: 8 · 2012: 6
- FWCI
- 0.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Universal Access in the Information Society (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Physical Sciences › Computer Science › Human-Computer Interaction › Interactive and Immersive Displays
- Health Sciences › Health Professions › Occupational Therapy › Assistive Technology in Communication and Mobility
- Keywords
- touchscreen interaction, blind users, gesture recognition, text entry, assistive technology, typing speed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.