Experimental measurement of dynamic fluid shear stress on the aortic surface of the aortic valve leaflet
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Aortic valve (AV) calcification is a highly prevalent disease with serious impact on mortality and morbidity. Although exact causes and mechanisms of AV calcification are unclear, previous studies suggest that mechanical forces play a role. Since calcium deposits occur almost exclusively on the aortic surfaces of AV leaflets, it has been hypothesized that adverse patterns of fluid shear stress on the aortic surface of AV leaflets promote calcification. The current study characterizes AV leaflet aortic surface fluid shear stresses using Laser Doppler velocimetry and an in vitro pulsatile flow loop. The valve model used was a native porcine valve mounted on a suturing ring and preserved using 0.15% glutaraldehyde solution. This valve model was inserted in a mounting chamber with sinus geometries, which is made of clear acrylic to provide optical access for measurements. To understand the effects of hemodynamics on fluid shear stress, shear stress was measured across a range of conditions: varying stroke volumes at the same heart rate and varying heart rates at the same stroke volume. Systolic shear stress magnitude was found to be much higher than diastolic shear stress magnitude due to the stronger flow in the sinuses during systole, reaching up to 20 dyn/cm2 at mid-systole. Upon increasing stroke volume, fluid shear stresses increased due to stronger sinus fluid motion. Upon increasing heart rate, fluid shear stresses decreased due to reduced systolic duration that restricted the formation of strong sinus flow. Significant changes in the shear stress waveform were observed at 90 beats/min, most likely due to altered leaflet dynamics at this higher heart rate. Overall, this study represents the most well-resolved shear stress measurements to date across a range of conditions on the aortic side of the AV. The data presented can be used for further investigation to understand AV biological response to shear stresses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical Factors Associated With Calcific Aortic Valve Disease
Stewart, B. F., Siscovick, D., Lind, B. K., Gardin, J. M., Gottdiener, J. S., Smith, V. E., Kitzman, D. W., & Otto, C. M. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00563-3 · Cited by 2,029 · cited 2×
“…in morphology between atherosclerosis and AV sclerosis lesions (Otto et al. 1994) and that these two diseases share common risk factors (Stewart et al. 1997; Agmon et al. 2001), one is inclined to hypothesize that similar mechanotransduction pathways of calcification may apply to AV…”
BackgroundChatzizisis, Y. S., Coskun, A. U., Jonas, M., Edelman, E. R., Feldman, C. L., & Stone, P. H. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.02.059 · Cited by 1,483 · cited 2×
“to vascular endothelium sclerosis (Ku et al. 1985; Chatzizisis et al. 2007).”
BackgroundFreeman, R. V., & Otto, C. M. (2005) · Circulation · doi:10.1161/circulationaha.104.486738 · Cited by 1,006 · cited 2×
“Further, it has been speculated that the reduced shear stresses on the non-coronary leaflet of the aortic valve (AV) due to the lack of coronary flow is responsible for the increased susceptibility to calcification of that leaflet (Freeman and Otto 2005).”
Cited by
Calcific aortic valve disease: from molecular and cellular mechanisms to medical therapy
Kraler, S., Blaser, M. C., Aikawa, E., Camici, G. G., & Lüscher, T. F. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehab757 · Cited by 281
Schlotter, F., Halu, A., Goto, S., Blaser, M. C., Body, S. C., Lee, L. H., Higashi, H., DeLaughter, D. M., Hutcheson, J. D., Vyas, P., et al. (2018) · Circulation · doi:10.1161/circulationaha.117.032291 · Cited by 256
Drug Targeting via Platelet Membrane–Coated Nanoparticles
Wang, S., Duan, Y., Zhang, Q., Komarla, A., Gong, H., Gao, W., & Zhang, L. (2020) · Small Structures · doi:10.1002/sstr.202000018 · Cited by 233
Chen, M. B., Srigunapalan, S., Wheeler, A. R., & Simmons, C. A. (2013) · Lab on a Chip · doi:10.1039/c3lc00051f · Cited by 179
Cyclic strain induces dual-mode endothelial-mesenchymal transformation of the cardiac valve
Balachandran, K., Alford, P. W., Wylie-Sears, J., Goss, J. A., Grosberg, A., Bischoff, J., Aikawa, E., Levine, R. A., & Parker, K. K. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1106954108 · Cited by 176
“VECs in the outflow surface generally exhibit no preferred orientation and are isotropic (23) due to oscillatory blood flow patterns (26).”
Background
Metadata
- Authors
- Yap, C. H., Saikrishnan, N., Tamilselvan, G., & Yoganathan, A. P.
- Venue
- Biomechanics and Modeling in Mechanobiology
- Published
- 2011-03-18
- Volume
- 11
- Issue
- 1-2
- Pages
- 171-182
- ISSN
- 1617-7940 (ISSN-L)
- 1617-7959
- OpenAlex
- W1997586890
- Cited by
- 138
- References
- 3
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.