Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 179

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

A 3D microfluidic platform incorporating methacrylated gelatin hydrogels to study physiological cardiovascular cell–cell interactions

Chen, Michelle B., Srigunapalan, Suthan, Wheeler, Aaron R., Simmons, Craig A. · 2013 · Lab on a Chip

Abstract

The cardiovascular system is particularly well-suited to modelling with microfluidic technologies, and much progress has been made to create microfluidic devices that mimic the microvasculature. In contrast, microfluidic platforms that model larger blood vessels and heart valves are lacking, despite the clear potential benefits of improved physiological relevance and enhanced throughput over traditional cell culture technologies. To address this need, we developed a bilayer membrane microfluidic device to model the vascular/valvular three-dimensional environment. Key features of the platform include physiologically-relevant spatial arrangement of multiple cell types, fluid flow over an endothelial monolayer, a porous membrane that permits heterotypic cell interactions while maintaining cell compartmentalization, and a photopolymerizable gelatin methacrylate (gel-MA) hydrogel as a physiologically-relevant subendothelial 3D matrix. Processing guidelines were defined for successful in-channel polymerization of gel-MA hydrogels that were mechanically stable, had physiologically-relevant elastic moduli of 2-30 kPa, and supported over 80% primary cell viability for at least four days in culture. The platform was applied to investigate shear stress-regulated paracrine interactions between valvular endothelial cells and valvular interstitial cells. The presence of endothelial cells significantly suppressed interstitial cell pathological differentiation to α-smooth muscle actin-positive myofibroblasts, an effect that was enhanced when the endothelium was exposed to flow-induced shear stress. We expect this versatile organ-on-a-chip platform to have broad utility for mechanistic vascular and valvular biology studies and to be useful for drug screening in physiologically-relevant 3D cardiovascular microenvironments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3lc00051f

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 179

Metadata

Authors
Chen, M. B., Srigunapalan, S., Wheeler, A. R., & Simmons, C. A.
Venue
Lab on a Chip
Published
2013
Volume
13
Issue
13
Pages
2591
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2099728849
Cited by
179
References
4
FWCI
7.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A 3D microfluidic platform incorporating methacrylated gelatin hydrogels to study physiological cardiovascular cell–cell interactions. https://app.cochat.ai/papers/10.1039/c3lc00051f
The paper
Chen, M. B., Srigunapalan, S., Wheeler, A. R., & Simmons, C. A. (2013). A 3D microfluidic platform incorporating methacrylated gelatin hydrogels to study physiological cardiovascular cell–cell interactions. Lab on a Chip. https://doi.org/10.1039/c3lc00051f

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.