Association between vasovagal hypotension and low sympathetic neural activity during presyncope
The DOI matches its Crossref record.
Abstract
Recent studies suggest that an underlying mechanism for susceptibility of patients and astronauts to presyncope includes hypoadrenergic responses to orthostatic stress. However, data used to reach this conclusion are open to various interpretations. In this report, maintenance of sympathetic neural activity (MSNA; peroneal nerve microneurography) during -60 mmHg lower body negative pressure (LBNP) was associated with maintenance of orthostatic tolerance, and disappearance of MSNA was associated with hypotension and pre-syncope. However, MSNA was substantially higher during progressive increases of negative pressure in the presyncopal subject, compared to the non-presyncopal subjects. The data from this case report question the notion that orthostatic hypotension occurs due to inadequate sympathetic neural activation during orthostatic stress in apparently normal, healthy subjects.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, 2 groups have recently reported persistence of MSNA during vasovagal syncope, bringing into question the role of sympathetic activity withdrawal as the final physiologic event that precipitates loss of consciousness.85,86”
Citations
Cites
Still being checked.
Cited by
Sheldon, R. S., Grubb, B. P., Olshansky, B., Shen, W.-K., Calkins, H., Brignole, M., Raj, S. R., Krahn, A. D., Morillo, C. A., Stewart, J. M., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.03.029 · Cited by 1,013
“However, 2 groups have recently reported persistence of MSNA during vasovagal syncope, bringing into question the role of sympathetic activity withdrawal as the final physiologic event that precipitates loss of consciousness.(85,86) These studies challenge the hypothesis that abrupt sympathetic nerve activity withdraw…”
BackgroundLower body negative pressure as a model to study progression to acute hemorrhagic shock in humans
Cooke, W. H., Ryan, K. L., & Convertino, V. A. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01155.2003 · Cited by 346
Self-citationLower Body Negative Pressure: Physiological Effects, Applications, and Implementation
Goswami, N., Blaber, A. P., Hinghofer-Szalkay, H., & Convertino, V. A. (2019) · Physiological Reviews · doi:10.1152/physrev.00006.2018 · Cited by 217
Self-citationHeart Rate Variability and Its Association with Mortality in Prehospital Trauma Patients
Cooke, W. H., Salinas, J., Convertino, V. A., Ludwig, D. A., Hinds, D., Duke, J. H., Moore, F. A., & Holcomb, J. B. (2006) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000196623.48952.0e · Cited by 162
Self-citationMano, T., Iwase, S., & Toma, S. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.06.002 · Cited by 158
Peripheral Perfusion Index as an Early Predictor for Central Hypovolemia in Awake Healthy Volunteers
van Genderen, M. E., Bartels, S. A., Lima, A. A. P., Bezemer, R., İnce, C., Bakker, J., & van Bommel, J. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318274e151 · Cited by 143
Convertino, V. A., Cooke, W. H., & Holcomb, J. B. (2006) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000196663.34175.33 · Cited by 132
Self-citationCooke, W. H., Rickards, C. A., Ryan, K. L., Kuusela, T., & Convertino, V. A. (2009) · The Journal of Physiology · doi:10.1113/jphysiol.2009.177352 · Cited by 127
Self-citationLBNP: Past Protocols and Technical Considerations for Experimental Design
Goswami, N., Loeppky, J. A., & Hinghofer-Szalkay, H. G. (2008) · Aviation Space and Environmental Medicine · doi:10.3357/asem.2161.2008 · Cited by 104
Convertino, V. A., Ludwig, D. A., & Cooke, W. H. (2004) · Autonomic Neuroscience · doi:10.1016/j.autneu.2004.02.007 · Cited by 100
Self-citationMonitoring peripheral perfusion in critically ill patients at the bedside
van Genderen, M. E., van Bommel, J., & Lima, A. A. P. (2012) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e3283533924 · Cited by 81
Cooke, W. H., & Convertino, V. A. (2005) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000151345.16338.fd · Cited by 68
Self-citationRickards, C. A., Ryan, K. L., Cooke, W. H., Lurie, K. G., & Convertino, V. A. (2007) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00087.2007 · Cited by 61
Self-citationSympathetic Responses to Central Hypovolemia: New Insights from Microneurographic Recordings
Ryan, K. L., Rickards, C. A., Hinojosa‐Laborde, C., Cooke, W. H., & Convertino, V. A. (2012) · Frontiers in Physiology · doi:10.3389/fphys.2012.00110 · Cited by 55
Self-citationJardine, D. L. (2012) · Cardiology Clinics · doi:10.1016/j.ccl.2012.10.010 · Cited by 52
Gravitational and Space Biology
Landis, W. J. (2005) · Cited by 49
Alian, A. A., Galante, N. J., Stachenfeld, N. S., Silverman, D. G., & Shelley, K. H. (2011) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-011-9316-y · Cited by 39
Convertino, V. A. (2005) · PubMed · Cited by 39
Self-citationAlian, A. A., Galante, N. J., Stachenfeld, N. S., Silverman, D. G., & Shelley, K. H. (2011) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-011-9317-x · Cited by 32
Hachiya, T., Walsh, M. L., Saito, M., & Blaber, A. P. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00593.2009 · Cited by 25
Huang, P., He, X., & Xu, M. (2020) · BioMed Research International · doi:10.1155/2020/6634537 · Cited by 23
RetractedXiang, L., Hinojosa‐Laborde, C., Ryan, K. L., Rickards, C. A., & Convertino, V. A. (2018) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00361.2017 · Cited by 23
Self-citationRole of individual predisposition in orthostatic intolerance before and after simulated microgravity
Grenon, S. M., Hurwitz, S., Sheynberg, N., Xiao, X. G., Ramsdell, C. D., L., C., Kim, C., Cohen, R. J., & Williams, G. H. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01274.2003 · Cited by 22
Sympathetic mechanisms in an animal model of vasovagal syncope
He, W.-B., Wang, X., Liu, S., Yu, X.-M., Lu, Z.-B., Ma, R.-S., Luo, D., Xie, J., He, B., & Jiang, H. (2018) · Clinical Autonomic Research · doi:10.1007/s10286-018-0503-5 · Cited by 7
Sympathetic nervous system and spaceflight
Cooke, W. H., & Convertino, V. A. (2006) · Acta Astronautica · doi:10.1016/j.actaastro.2006.08.003 · Cited by 7
Self-citationde Moraes, J. M. S., Vane, M. F., Rodrigues, D. D. F., Mostarda, C. T., de Moraes, T. S. M. M., Vane, L. F., Ganem, E. M., Cavalcanti, I. L., Módolo, N. S. P., & Vane, L. A. (2014) · Acta Cirúrgica Brasileira · doi:10.1590/s0102-86502014001800002 · Cited by 3
Iacovelli, J. J., Alpenglow, J. K., Waldron, J. S., Simmons, J. M., Bunsawat, K., Carter, S. J., & Wray, D. W. (2026) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00827.2025 · Cited by 2
Hachiya, T. (2006) · Summit (Simon Fraser University) · Cited by 1
Noninvasive Monitoring of Peripheral Perfusion in Critically Ill Patients
Lima, A. A. P. (2013) · RePub (Erasmus University Rotterdam) · Cited by 2
McLeod, J. D. (2016) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 1
Jun, I., Park, J. Y., Sang, B. H., Park, J. Y., Joo, J. Y., & Hwang, G. S. (2009) · Korean Journal of Anesthesiology · doi:10.4097/kjae.2009.56.3.265
Ramalho, G. L. (2015) · Americanae (AECID Library)
Kean, D. J. (2012) · OhioLink ETD Center (Ohio Library and Information Network)
Leite, M. A. (2018) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.17.2018.tde-24042018-171611
Metadata
- Authors
- Cooke, W. H., & Convertino, V. A.
- Affiliations
- Michigan Technological University (US)
- ORCID
- Cooke, William H.
- Venue
- Clinical Autonomic Research
- Published
- 2002-12-01
- Volume
- 12
- Issue
- 6
- Pages
- 483-486
- ISSN
- 0959-9851 (ISSN-L)
- 1619-1560
- OpenAlex
- W2046627267
- Semantic Scholar
- 1f7b66ef235ae5bc2d8430286b82d08aa23ff0e7
- Cited by
- 31
- References
- 0
- Citations by year
- 2020: 1 · 2018: 4 · 2015: 1 · 2014: 1 · 2013: 2 · 2012: 4
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Clinical Autonomic Research (publishedVersion)
- PubMed (publishedVersion)
- Digital Commons - Michigan Tech (Michigan Technological University) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Physiology (medical) › Spaceflight effects on biology
- Keywords
- presyncope, orthostatic tolerance, lower body negative pressure, orthostatic stress, astronauts
- MeSH terms
- Adult, Electrocardiography, Humans, Lower Body Negative Pressure, Male, Middle Aged, Peroneal Nerve, Sympathetic Nervous System, Syncope, Case-Control Studies, Muscle, Skeletal, Syncope, Vasovagal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.