A rapid magnetic particle driven micromixer
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Micromixers—a review on passive and active mixing principles
Hessel, V., Löwe, H., & Schönfeld, F. (2005) · Chemical Engineering Science · doi:10.1016/j.ces.2004.11.033 · Cited by 1,479 · cited 1×
“Active micromixers utilizing magnetic forces represent another important class of mixing possibility (Hessel et al. 2005; Nguyen et al. 2005).”
BackgroundPamme, N. (2006) · Lab Chip · doi:10.1039/b513005k · Cited by 1,129
Magnetic bead handling on-chip: new opportunities for analytical applications
Gijs, M. A. M. (2004) · Microfluidics and Nanofluidics · doi:10.1007/s10404-004-0010-y · Cited by 749 · cited 7×
“Actuated by magnetic forces, the suspended magnetic particles can add agitation and chaotic advection in the fluid flow and thus enhance the mixing (Rida and Gijs 2004a; Suzuki et al. 2004).”
BackgroundMethodResultInfluentialElectrokinetic Instability Micromixing
Oddy, M. H., Santiago, J. G., & Mikkelsen, J. C. (2001) · Analytical Chemistry · doi:10.1021/ac0155411 · Cited by 693 · cited 1×
“Electrokinetic mixers are favorable among active micromixers because of their simplicity and ease of integration to microfluidic chips (Biddiss et al. 2004; Jacobson et al 1999; Oddy et al. 2001; Santiago 2001; Wang et al. 2007; Xuan and Li 2005).”
BackgroundA magnetic microstirrer and array for microfluidic mixing
Lu, L.-H., Ryu, K. S., & Liu, C. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.802899 · Cited by 446 · cited 3×
“These include ultrasonic excitation (Yang et al. 2001), mechanical stirrers (Lu et al. 2002; Ryu et al. 2004), thermal bubble mixing (Tsai and Lin 2002), dielectrophoretic mixing (Deval et al. 2002), bubble acoustic agitation (Liu et al. 2002), shear superposition micromixer (Bottausci et al.…”
BackgroundMethodA novel in-plane passive microfluidic mixer with modified Tesla structures
Hong, C.-C., Choi, J.-W., & Ahn, C. H. (2004) · Lab on a Chip · doi:10.1039/b305892a · Cited by 429 · cited 1×
“Using passive structures, the fluids are forced to change directions, split or reunify, to increase the contact areas of the sub-streams (Bessoth et al. 1999; Hong et al. 2004; Losey et al. 2002; Mengeaud et al. 2002).”
BackgroundUltrasonic micromixer for microfluidic systems
Yang, Z., Matsumoto, S., Goto, H., Matsumoto, M., & Maeda, R. (2001) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00654-9 · Cited by 421
Bubble-induced acoustic micromixing
Liu, R. H., Yang, J., Pindera, M. Z., Athavale, M., & Grodzinski, P. (2002) · Lab on a Chip · doi:10.1039/b201952c · Cited by 374 · cited 2×
“…include ultrasonic excitation (Yang et al. 2001), mechanical stirrers (Lu et al. 2002; Ryu et al. 2004), thermal bubble mixing (Tsai and Lin 2002), dielectrophoretic mixing (Deval et al. 2002), bubble acoustic agitation (Liu et al. 2002), shear superposition micromixer (Bottausci et al. 2004), etc.”
BackgroundElectroosmotic Flows in Microchannels with Finite Inertial and Pressure Forces
Santiago, J. G. (2001) · Analytical Chemistry · doi:10.1021/ac0101398 · Cited by 287 · cited 1×
“Electrokinetic mixers are favorable among active micromixers because of their simplicity and ease of integration to microfluidic chips (Biddiss et al. 2004; Jacobson et al 1999; Oddy et al. 2001; Santiago 2001; Wang et al. 2007; Xuan and Li 2005).”
Background
Cited by
Lee, C.-Y., Chang, C.-L., Wang, Y.-N., & Fu, L.-M. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12053263 · Cited by 1,111
Self-citationMicrofluidic Applications of Magnetic Particles for Biological Analysis and Catalysis
Gijs, M. A. M., Lacharme, F., & Lehmann, U. (2010) · Chemical Reviews · doi:10.1021/cr9001929 · Cited by 679
Liquid metal enabled microfluidics
Khoshmanesh, K., Tang, S.-Y., Zhu, J. Y., Schaefer, S., Mitchell, A., Kalantar-zadeh, K., & Dickey, M. D. (2017) · Lab on a Chip · doi:10.1039/c7lc00046d · Cited by 458
van Reenen, A., de Jong, A. M., den Toonder, J. M. J., & Prins, M. W. J. (2014) · Lab Chip · doi:10.1039/c3lc51454d · Cited by 262
Huang, T., Sakar, M. S., Mao, A., Petruska, A. J., Qiu, F., Chen, X., Kennedy, S., Mooney, D., & Nelson, B. J. (2015) · Advanced Materials · doi:10.1002/adma.201503095 · Cited by 239
Recent advances and current challenges in magnetophoresis based micro magnetofluidics
Munaz, A., Shiddiky, M. J. A., & Nguyen, N.-T. (2018) · Biomicrofluidics · doi:10.1063/1.5035388 · Cited by 164
Metadata
- Authors
- Wang, Y., Zhe, J., Chung, B. T. F., & Dutta, P.
- Venue
- Microfluidics and Nanofluidics
- Published
- 2007-06-30
- Volume
- 4
- Issue
- 5
- Pages
- 375-389
- ISSN
- 1613-4982 (ISSN-L)
- 1613-4990
- OpenAlex
- W2083930329
- Cited by
- 163
- References
- 21
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.