The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Bubble-induced acoustic micromixing
Abstract
A mixing technique based on the principle of bubble-induced acoustic microstreaming was developed. The mixer consists of a piezoelectric disk that is attached to a reaction chamber, which is designed in such a way that a set of air bubbles with desirable size is trapped in the solution. Fluidic experiments showed that air bubbles resting on a solid surface and set into vibration by the sound field generated steady circulatory flows, resulting in global convection flows and thus rapid mixing. The time to fully mix a 22 microL chamber is significantly reduced from hours (for a pure diffusion-based mixing) to tens of seconds. Numerical simulations showed that the induced flowfield and thus degree of mixing strongly depend on bubble positions. Optimal simulated mixing results were obtained for staggered bubble distribution that minimizes the number of internal flow stagnation regions. Immunomagnetic cell capture experiments showed that acoustic microstreaming provided efficient mixing of bacterial cell (Esherichia coli K12) matrix suspended in blood with magnetic capture beads, resulting in highly effective immunomagnetic cell capture. Bacterial viability assay experiments showed that acoustic microstreaming has a relatively low shear strain field since the blood cells and bacteria remained intact after mixing. Acoustic microstreaming has many advantages over most existing chamber micromixing techniques, including simple apparatus, ease of implementation, low power consumption (2 mW), and low cost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical and Chemical Aspects of Ultrasonic Disruption of Cells
Clarke, P. R., & Hill, C. R. (1970) · The Journal of the Acoustical Society of America · doi:10.1121/1.1911940 · Cited by 203
Micro mixer with fast diffusion
Miyake, R., Lammerink, T. S. J., Elwenspoek, M., et al. (2002) · Proceedings, IEEE micro electro mechanical systems · doi:10.1109/memsys.1993.296914 · Cited by 141
Hemolysis Near a Transversely Oscillating Wire
Williams, A. R., Hughes, D. E., & Nyborg, W. L. (1970) · Science · doi:10.1126/science.169.3948.871 · Cited by 133
High Resolution Mixer for the Study of the Kinetics of Rapid Reactions in Solution
Berger, R. L., Balko, B., & Chapman, H. F. (1968) · Review of Scientific Instruments · doi:10.1063/1.1683415 · Cited by 96
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Micromixers—a review on passive and active mixing principles
Hessel, V., Löwe, H., & Schönfeld, F. (2005) · Chemical Engineering Science · doi:10.1016/j.ces.2004.11.033 · Cited by 1,479
Deciding Whether To Go with the Flow: Evaluating the Merits of Flow Reactors for Synthesis
Hartman, R. L., McMullen, J. P., & Jensen, K. F. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201004637 · Cited by 999
Physics of bubble oscillations
Lauterborn, W., & Kurz, T. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/10/106501 · Cited by 816
Applications of Acoustics and Cavitation to Noninvasive Therapy and Drug Delivery
Coussios, C. C., & Roy, R. A. (2008) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.40.111406.102116 · Cited by 532
Metadata
- Authors
- Liu, R. H., Yang, J., Pindera, M. Z., Athavale, M., & Grodzinski, P.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2002
- Volume
- 2
- Issue
- 3
- Pages
- 151
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2055279563
- Cited by
- 374
- References
- 4
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bubble-induced acoustic micromixing. https://app.cochat.ai/papers/10.1039/b201952c
- The paper
- Liu, R. H., Yang, J., Pindera, M. Z., Athavale, M., & Grodzinski, P. (2002). Bubble-induced acoustic micromixing. Lab on a Chip. https://doi.org/10.1039/b201952c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.