The DOI matches its Crossref record; 161 of the 161 references it cites were found in a registry or an index.
Microfluidic chips: recent advances, critical strategies in design, applications and future perspectives
Open accessAbstract
Microfluidic chip technology is an emerging tool in the field of biomedical application. Microfluidic chip includes a set of groves or microchannels that are engraved on different materials (glass, silicon, or polymers such as polydimethylsiloxane or PDMS, polymethylmethacrylate or PMMA). The microchannels forming the microfluidic chip are interconnected with each other for desired results. This organization of microchannels trapped into the microfluidic chip is associated with the outside by inputs and outputs penetrating through the chip, as an interface between the macro- and miniature world. With the help of a pump and a chip, microfluidic chip helps to determine the behavioral change of the microfluids. Inside the chip, there are microfluidic channels that permit the processing of the fluid, for example, blending and physicochemical responses. Microfluidic chip has numerous points of interest including lesser time and reagent utilization and alongside this, it can execute numerous activities simultaneously. The miniatured size of the chip fastens the reaction as the surface area increases. It is utilized in different biomedical applications such as food safety sensing, peptide analysis, tissue engineering, medical diagnosis, DNA purification, PCR activity, pregnancy, and glucose estimation. In the present study, the design of various microfluidic chips has been discussed along with their biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ror2 signaling regulates Golgi structure and transport through IFT20 for tumor invasiveness
Nishita, M., Park, S.-Y., Nishio, T., Kamizaki, K., Wang, Z., Tamada, K., Takumi, T., Hashimoto, R., Otani, H., Pazour, G. J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-016-0028-x · Cited by 15,947
Ultrastructural Characterization of the Lower Motor System in a Mouse Model of Krabbe Disease
Cappello, V., Marchetti, L., Parlanti, P., Landi, S., Tonazzini, I., Cecchini, M., Piazza, V., & Gemmi, M. (2016) · Scientific Reports · doi:10.1038/s41598-016-0001-8 · Cited by 13,097
Molecular Mechanisms of Stress-Responsive Changes in Collagen and Elastin Networks in Skin
Aziz, J., Shezali, H., Radzi, Z., Yahya, N. A., Abu Kassim, N. H., Czernuszka, J., & Rahman, M. T. (2016) · Skin Pharmacology and Physiology · doi:10.1159/000447017 · Cited by 7,323
Identification of Essential Oil Components By Gas Chromatography/Mass Spectrometry
Adams, R. P. (2007) · Cited by 6,139
Anomalous collapses of Nares Strait ice arches leads to enhanced export of Arctic sea ice
Moore, G. W. K., Howell, S. E. L., Brady, M., Xu, X., & McNeil, K. (2021) · Nature Communications · doi:10.1038/s41467-020-20314-w · Cited by 5,155
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Introduction to Modern Liquid Chromatography
Snyder, L. R., Kirkland, J. J., & Dolan, J. W. (2009) · Wiley eBooks · doi:10.1002/9780470508183 · Cited by 2,460
Formation of droplets and bubbles in a microfluidic T-junction—scaling and mechanism of break-up
Garstecki, P., Fuerstman, M. J., Stone, H. A., & Whitesides, G. M. (2006) · Lab on a Chip · doi:10.1039/b510841a · Cited by 2,339
Cited by
Enhancing the sustainability of microalgae cultivation through biosensing technology
Ugya, A. Y., Chen, H., & Wang, Q. (2025) · Materials Today Sustainability · doi:10.1016/j.mtsust.2025.101139 · Cited by 5
Metadata
- Authors
- Pattanayak, P., Singh, S. K., Gulati, M., Vishwas, S., Kapoor, B., Chellappan, D. K., Anand, K., Gupta, G., Jha, N. K., Gupta, P. K., Prasher, P., Dua, K., Dureja, H., Kumar, D., & Kumar, V.
- Venue
- Microfluidics and Nanofluidics
- Published
- 2021-10-26
- Volume
- 25
- Issue
- 12
- Pages
- 99-99
- ISSN
- 1613-4982 (ISSN-L)
- 1613-4990
- OpenAlex
- W3210770444
- Cited by
- 330
- References
- 161
- FWCI
- 11.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfluidic chips: recent advances, critical strategies in design, applications and future perspectives. https://app.cochat.ai/papers/10.1007/s10404-021-02502-2
- The paper
- Pattanayak, P., Singh, S. K., Gulati, M., Vishwas, S., Kapoor, B., Chellappan, D. K., Anand, K., Gupta, G., Jha, N. K., Gupta, P. K., Prasher, P., Dua, K., Dureja, H., Kumar, D., & Kumar, V. (2021). Microfluidic chips: recent advances, critical strategies in design, applications and future perspectives. Microfluidics and Nanofluidics. https://doi.org/10.1007/s10404-021-02502-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.