Effect of Strain Magnitude on the Tissue Properties of Engineered Cardiovascular Constructs
Open accessThe DOI matches its Crossref record.
Abstract
Mechanical loading is a powerful regulator of tissue properties in engineered cardiovascular tissues. To ultimately regulate the biochemical processes, it is essential to quantify the effect of mechanical loading on the properties of engineered cardiovascular constructs. In this study the Flexercell FX-4000T (Flexcell Int. Corp., USA) straining system was modified to simultaneously apply various strain magnitudes to individual samples during one experiment. In addition, porous polyglycolic acid (PGA) scaffolds, coated with poly-4-hydroxybutyrate (P4HB), were partially embedded in a silicone layer to allow long-term uniaxial cyclic mechanical straining of cardiovascular engineered constructs. The constructs were subjected to two different strain magnitudes and showed differences in biochemical properties, mechanical properties and organization of the microstructure compared to the unstrained constructs. The results suggest that when the tissues are exposed to prolonged mechanical stimulation, the production of collagen with a higher fraction of crosslinks is induced. However, straining with a large strain magnitude resulted in a negative effect on the mechanical properties of the tissue. In addition, dynamic straining induced a different alignment of cells and collagen in the superficial layers compared to the deeper layers of the construct. The presented model system can be used to systematically optimize culture protocols for engineered cardiovascular tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cyclic stretching of soft substrates induces spreading and growth
Cui, Y., Hameed, F. M., Yang, B., Lee, K., Pan, C. Q., Park, S., & Sheetz, M. (2015) · Nature Communications · doi:10.1038/ncomms7333 · Cited by 320
Substrates for cardiovascular tissue engineering
Bouten, C. V. C., Dankers, P. Y. W., Driessen-Mol, A., Pedron, S., Brizard, A. M. A., & Baaijens, F. P. T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.007 · Cited by 261
Self-citationBioengineering Challenges for Heart Valve Tissue Engineering
Sacks, M. S., Schoen, F. J., & Mayer, J. E. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124903 · Cited by 256
Strain-dependent modulation of macrophage polarization within scaffolds
Ballotta, V., Driessen-Mol, A., Bouten, C. V. C., & Baaijens, F. P. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.03.002 · Cited by 182
Self-citation
Metadata
- Authors
- Boerboom, R. A., Rubbens, M. P., Driessen, N. J. B., Bouten, C. V. C., & Baaijens, F. P. T.
- Venue
- Annals of Biomedical Engineering
- Published
- 2007-12-08
- Volume
- 36
- Issue
- 2
- Pages
- 244-253
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2027085375
- Cited by
- 78
- References
- 0
- FWCI
- 6.73
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.