RETRACTED ARTICLE: Non-thermal Plasma Induces Apoptosis in Melanoma Cells via Production of Intracellular Reactive Oxygen Species
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Non-thermal atmospheric pressure dielectric barrier discharge (DBD) plasma may provide a novel approach to treat malignancies via induction of apoptosis. The purpose of this study was to evaluate the potential of DBD plasma to induce apoptosis in melanoma cells. Melanoma cells were exposed to plasma at doses that did not induce necrosis, and cell viability and apoptotic activity were evaluated by Trypan blue exclusion test, Annexin-V/PI staining, caspase-3 cleavage, and TUNEL® analysis. Trypan blue staining revealed that non-thermal plasma treatment significantly decreased the viability of cells in a dose-dependent manner 3 and 24 h after plasma treatment. Annexin-V/PI staining revealed a significant increase in apoptosis in plasma-treated cells at 24, 48, and 72 h post-treatment (p < 0.001). Caspase-3 cleavage was observed 48 h post-plasma treatment at a dose of 15 J/cm2. TUNEL® analysis of plasma-treated cells demonstrated an increase in apoptosis at 48 and 72 h post-treatment (p < 0.001) at a dose of 15 J/cm2. Pre-treatment with N-acetyl-l-cysteine (NAC), an intracellular reactive oxygen species (ROS) scavenger, significantly decreased apoptosis in plasma-treated cells at 5 and 15 J/cm2. Plasma treatment induces apoptosis in melanoma cells through a pathway that appears to be dependent on production of intracellular ROS. DBD plasma production of intracellular ROS leads to dose-dependent DNA damage in melanoma cells, detected by γ-H2AX, which was completely abrogated by pre-treating cells with ROS scavenger, NAC. Plasma-induced DNA damage in turn may lead to the observed plasma-induced apoptosis. Since plasma is non-thermal, it may be used to selectively treat malignancies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DNA double-stranded breaks induce histone H2AX phosphorylation on serine 139
Rogakou, E. P., Pilch, D. R., Orr, A. H., Ivanova, V. S., & Bonner, W. M. (1998) · Journal of Biological Chemistry · doi:10.1074/jbc.273.10.5858 · Cited by 5,438
Apoptosis, oncosis, and necrosis. An overview of cell death.
Majno, G., & Joris, I. (1995) · PubMed Central · Cited by 4,150
Fridman, A. (2008) · Cambridge University Press eBooks · doi:10.1017/cbo9780511546075 · Cited by 1,776
Self-citationMolecular mechanisms of N-acetylcysteine actions
Zafarullah, M., Li, W. Q., Sylvester, J., & Ahmad, M. (2003) · Cellular and Molecular Life Sciences (CMLS) · doi:10.1007/s000180300001 · Cited by 1,343
Low Temperature Plasma‐Based Sterilization: Overview and State‐of‐the‐Art
Laroussi, M. (2005) · Plasma Processes and Polymers · doi:10.1002/ppap.200400078 · Cited by 1,111
Non-thermal atmospheric pressure discharges
Fridman, A., Chirokov, A., & Gutsol, A. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/2/r01 · Cited by 1,005
Self-citationLaroussi, M., & Leipold, F. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2003.11.016 · Cited by 866
More than one way to die: apoptosis, necrosis and reactive oxygen damage
Fiers, W., Beyaert, R., Declercq, W., & Vandenabeele, P. (1999) · Oncogene · doi:10.1038/sj.onc.1203249 · Cited by 864
Apoptosis and melanoma chemoresistance
Soengas, M. S., & Lowe, S. W. (2003) · Oncogene · doi:10.1038/sj.onc.1206454 · Cited by 826
Reed, J. C. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd726 · Cited by 643
Cited by
Graves, D. B. (2012) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/45/26/263001 · Cited by 1,518
von Woedtke, T., Reuter, S., Masur, K., & Weltmann, K.-D. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.05.005 · Cited by 848
ROS implication in a new antitumor strategy based on non‐thermal plasma
Vandamme, M., Robert, E., Lerondel, S., Sarron, V., Ries, D., Dozias, S., Sobilo, J., Gosset, D., Kieda, C., Legrain, B., et al. (2012) · International Journal of Cancer · doi:10.1002/ijc.26252 · Cited by 606
Han, L., Patil, S., Boehm, D., Milosavljević, V., Cullen, P. J., & Bourke, P. (2016) · Applied and Environmental Microbiology · doi:10.1128/aem.02660-15 · Cited by 435
Cold Atmospheric Plasma: methods of production and application in dentistry and oncology
Hoffmann, C., Berganza, C., & Zhang, J. (2013) · Medical Gas Research · doi:10.1186/2045-9912-3-21 · Cited by 412
Utsumi, F., Kajiyama, H., Nakamura, K., Tanaka, H., Mizuno, M., Ishikawa, K., Kondo, H., Kano, H., Hori, M., & Kikkawa, F. (2013) · PLoS ONE · doi:10.1371/journal.pone.0081576 · Cited by 408
Arndt, S., Unger, P., Wacker, E., Shimizu, T., Heinlin, J., Li, Y.-F., Thomas, H. M., Morfill, G. E., Zimmermann, J. L., Bosserhoff, A.-K., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0079325 · Cited by 364
Tian, Y., Ma, R., Zhang, Q., Feng, H., Liang, Y., Zhang, J., & Fang, J. (2015) · Plasma Processes and Polymers · doi:10.1002/ppap.201400082 · Cited by 263
Restoration of Sensitivity in Chemo — Resistant Glioma Cells by Cold Atmospheric Plasma
Köritzer, J., Boxhammer, V., Schäfer, A., Shimizu, T., Klämpfl, T. G., Li, Y.-F., Welz, C., Schwenk-Zieger, S., Morfill, G. E., Zimmermann, J. L., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0064498 · Cited by 249
“It was shown that intracellular ROS levels increase after CAP treatment, thereby inducing DNA damage and apoptosis in the cells [28], [25], [29], [30].”
Cold atmospheric plasma devices for medical issues
Isbary, G., Shimizu, T., Li, Y.-F., Stolz, W., Thomas, H. M., Morfill, G. E., & Zimmermann, J. L. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.13.4 · Cited by 221
Non-thermal dielectric barrier discharge plasma induces angiogenesis through reactive oxygen species
Arjunan, K. P., Friedman, G., Fridman, A., & Clyne, A. M. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0220 · Cited by 207
Self-citationFrom RONS to ROS: Tailoring Plasma Jet Treatment of Skin Cells
Reuter, S., Tresp, H., Wende, K., Hammer, M. U., Winter, J., Masur, K., Schmidt-Bleker, A., & Weltmann, K.-D. (2012) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2012.2207130 · Cited by 195
Ma, Y., Ha, C. S., Hwang, S. W., Lee, H. J., Kim, G. C., Lee, K.-W., & Song, K. (2014) · PLoS ONE · doi:10.1371/journal.pone.0091947 · Cited by 173
Metadata
- Authors
- Sensenig, R., Kalghatgi, S., Cerchar, E., Fridman, G., Shereshevsky, A., Torabi, B., Arjunan, K. P., Podolsky, E., Fridman, A., Friedman, G., Azizkhan-Clifford, J., & Brooks, A. D.
- Venue
- Annals of Biomedical Engineering
- Published
- 2010-10-29
- Volume
- 39
- Issue
- 2
- Pages
- 674-687
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2171062412
- Cited by
- 166
- References
- 38
- FWCI
- 11.33
- Type
- journal article
- Language
- en
- Status
- Retracted
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.