Patient-Specific Multiscale Modeling of Blood Flow for Coronary Artery Bypass Graft Surgery
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We present a computational framework for multiscale modeling and simulation of blood flow in coronary artery bypass graft (CABG) patients. Using this framework, only CT and non-invasive clinical measurements are required without the need to assume pressure and/or flow waveforms in the coronaries and we can capture global circulatory dynamics. We demonstrate this methodology in a case study of a patient with multiple CABGs. A patient-specific model of the blood vessels is constructed from CT image data to include the aorta, aortic branch vessels (brachiocephalic artery and carotids), the coronary arteries and multiple bypass grafts. The rest of the circulatory system is modeled using a lumped parameter network (LPN) 0 dimensional (0D) system comprised of resistances, capacitors (compliance), inductors (inertance), elastance and diodes (valves) that are tuned to match patient-specific clinical data. A finite element solver is used to compute blood flow and pressure in the 3D (3 dimensional) model, and this solver is implicitly coupled to the 0D LPN code at all inlets and outlets. By systematically parameterizing the graft geometry, we evaluate the influence of graft shape on the local hemodynamics, and global circulatory dynamics. Virtual manipulation of graft geometry is automated using Bezier splines and control points along the pathlines. Using this framework, we quantify wall shear stress, wall shear stress gradients and oscillatory shear index for different surgical geometries. We also compare pressures, flow rates and ventricular pressure–volume loops pre- and post-bypass graft surgery. We observe that PV loops do not change significantly after CABG but that both coronary perfusion and local hemodynamic parameters near the anastomosis region change substantially. Implications for future patient-specific optimization of CABG are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hemodynamic shear stress and its role in atherosclerosis
Malek, A. M. (1999) · JAMA · doi:10.1001/jama.282.21.2035 · Cited by 3,650
Finite element modeling of blood flow in arteries
Taylor, C. A., Hughes, T. J. R., & Zarins, C. K. (1998) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/s0045-7825(98)80008-x · Cited by 726
Cited by
SimVascular: An Open Source Pipeline for Cardiovascular Simulation
Updegrove, A., Wilson, N. M., Merkow, J., Lan, H., Marsden, A. L., & Shadden, S. C. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1762-8 · Cited by 651
Self-citationMultiscale Modeling Meets Machine Learning: What Can We Learn?
Peng, G. C. Y., Alber, M., Buganza Tepole, A., Cannon, W. R., De, S., Dura-Bernal, S., Garikipati, K., Karniadakis, G., Lytton, W. W., Perdikaris, P., et al. (2021) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-020-09405-5 · Cited by 353
A modular numerical method for implicit 0D/3D coupling in cardiovascular finite element simulations
Esmaily Moghadam, M., Vignon-Clementel, I. E., Figliola, R., & Marsden, A. L. (2013) · Journal of Computational Physics · doi:10.1016/j.jcp.2012.07.035 · Cited by 190
Self-citationRobust flow reconstruction from limited measurements via sparse representation
Callaham, J. L., Maeda, K., & Brunton, S. L. (2019) · Physical Review Fluids · doi:10.1103/physrevfluids.4.103907 · Cited by 178
Sankaran, S., Kim, H. J., Choi, G., & Taylor, C. A. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.01.002 · Cited by 166
“The outlets are modeled using a resistance condition which couples blood pressure and flow rate at the outlet (Kim et al., 2010; Vignon-Clementel et al., 2006; Sankaran et al., 2012).”
MethodSelf-citation
Metadata
- Authors
- Sankaran, S., Esmaily Moghadam, M., Kahn, A. M., Tseng, E. E., Guccione, J. M., & Marsden, A. L.
- Venue
- Annals of Biomedical Engineering
- Published
- 2012-04-27
- Volume
- 40
- Issue
- 10
- Pages
- 2228-2242
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2109389220
- Cited by
- 237
- References
- 2
- FWCI
- 9.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.