The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
SimVascular: An Open Source Pipeline for Cardiovascular Simulation
Open accessAbstract
Patient-specific cardiovascular simulation has become a paradigm in cardiovascular research and is emerging as a powerful tool in basic, translational and clinical research. In this paper we discuss the recent development of a fully open-source SimVascular software package, which provides a complete pipeline from medical image data segmentation to patient-specific blood flow simulation and analysis. This package serves as a research tool for cardiovascular modeling and simulation, and has contributed to numerous advances in personalized medicine, surgical planning and medical device design. The SimVascular software has recently been refactored and expanded to enhance functionality, usability, efficiency and accuracy of image-based patient-specific modeling tools. Moreover, SimVascular previously required several licensed components that hindered new user adoption and code management and our recent developments have replaced these commercial components to create a fully open source pipeline. These developments foster advances in cardiovascular modeling research, increased collaboration, standardization of methods, and a growing developer community.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Braunwald, E., Antman, E. M., Beasley, J. W., Califf, R. M., Cheitlin, M. D., Hochman, J. S., Jones, R. H., Kereiakes, D., Kupersmith, J., Levin, T. N., et al. (2000) · Circulation · doi:10.1161/01.cir.102.10.1193 · Cited by 4,487
Hemodynamic shear stress and its role in atherosclerosis
Malek, A. M. (1999) · JAMA · doi:10.1001/jama.282.21.2035 · Cited by 3,650
Ku, D. N., Giddens, D. P., Zarins, C. K., & Glagov, S. (1985) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.5.3.293 · Cited by 2,707
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
Li, C., Huang, R., Ding, Z., Gatenby, J. C., Metaxas, D. N., & Gore, J. C. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2011.2146190 · Cited by 1,285
Taylor, C. A., Fonte, T. A., & Min, J. K. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.083 · Cited by 1,208
Braunwald, E., Antman, E. M., Beasley, J. W., Califf, R. M., Cheitlin, M. D., Hochman, J. S., Jones, R. H., Kereiakes, D., Kupersmith, J., Levin, T. N., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02336-7 · Cited by 1,116
Review of MR image segmentation techniques using pattern recognition
Bezdek, J. C., Hall, L. O., & Clarke, L. P. (1993) · Medical Physics · doi:10.1118/1.597000 · Cited by 953
Braunwald, E. (2002) · Journal of the American College of Cardiology · Cited by 868
Olufsen, M. S., Peskin, C. S., Kim, W. Y., Pedersen, E. M., Nadim, A., & Larsen, J. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.1326031 · Cited by 862
Research works printed but not linked: 21
- Arzani, A., A. M. Gambaruto, G. Chen, and S. C. Shadden. Lagrangian wall shear stress structures and near wall transport in high schmidt aneurysmal flows. J. Fluid Mech. 790:158–172, 2016. · doi:10.1017/jfm.2016.6
- Arzani, A., A. S Les, R. L. Dalman, and S. C. Shadden. Effect of exercise on patient specific abdominal aortic aneurysm flow topology and mixing. Int. J. Numer. Methods Biomed. Eng. 30(2):280–295, 2014. · doi:10.1002/cnm.2601
- Arzani A., and S. C. Shadden. Characterization of the transport topology in patient-specific abdominal aortic aneurysm models. Phys. Fluids (1994-present) (1994), 24(8):081901, 2012. · doi:10.1063/1.4744984
- Bockman, M. D., A. P. Kansagra, S. C. Shadden, E. C. Wong, and A. L. Marsden. Fluid mechanics of mixing in the vertebrobasilar system: Cardiovasc. Eng. Technol. 3(4):450–461, 2012. · doi:10.1007/s13239-012-0112-8
- Bogren, H. G., R. H. Klipstein, D. N. Firmin, R. H. Mohiaddin, S. R. Underwood, R. S. O. Rees, and D. B. Longmore. Quantitation of antegrade and retrograde blood flow in the human aorta by magnetic resonance velocity mapping. Am. Heart J. 117(6):1214–1222, 1989. · doi:10.1016/0002-8703(89)90399-2
- Cheng, C. P., R. J. Herfkens, C. A. Taylor, and J. A. Feinstein. Proximal pulmonary artery blood flow characteristics in healthy subjects measured in an upright posture using MRI: the effects of exercise and age. J. Magn. Resonance Imaging 21(6):752–758, 2005. · doi:10.1002/jmri.20333
- Esmaily-Moghadam, M., T.-Y. Hsia, and A. L. Marsden. The Assisted Bidirectional Glenn: a novel surgical approach for first stage single ventricle heart palliation. J. Thorac. Cardiovasc. Surg. 149(3):699–705, 2015. · doi:10.1016/j.jtcvs.2014.10.035
- Hansen K. B., and S. C. Shadden. A reduced-dimensional model for near-wall transport in cardiovascular flows. Biomech. Model. Mechanobiol. 15(3):713–722, 2016. · doi:10.1007/s10237-015-0719-4
- Lonyai, A., A. M. Dubin, J. A. Feinstein, C. A. Taylor, and S. C. Shadden. New insights into pacemaker lead-induced venous occlusion: Simulation-based investigation of alterations in venous biomechanics. Cardiovasc. Eng. 10(2):84–90, 2010. · doi:10.1007/s10558-010-9096-x
- Lorigo, L. M., O. D. Faugeras, W. E. L. Grimson, R. Keriven, R. Kikinis, A. Nabavi, and C.-F. Westin. Curves: Curve evolution for vessel segmentation. Med. Image Anal. 5(3):195–206, 2001. · doi:10.1016/s1361-8415(01)00040-8
- Marsden, A. L., V. M. Reddy, S. C. Shadden, F. P. Chan, C. A. Taylor, and J. A. Feinstein. A new multiparameter approach to computational simulation for Fontan assessment and redesign. Congenit. Heart Dis. 5(2):104–117, 2010. · doi:10.1111/j.1747-0803.2010.00383.x
- Martin, M. H., J. A. Feinstein, F. P. Chan, A. L. Marsden, W. Yang, and V. M. Reddy. Technical feasibility and intermediate outcomes of a hand-crafted, area-preserving, bifurcated “Y-Graft” Fontan. Thorac. Cardiovasc. Surg. 149(1):247–255, 2015. · doi:10.1016/j.jtcvs.2014.08.058
- Merkow, J., Z. Tu, D. Kriegman, and A. L. Marsden. Structural edge detection for cardiovascular modeling. In: International Conference on Medical Image Computing and Computer-Assisted Intervention, pp. 735–742. Springer, New York, 2015. · doi:10.1007/978-3-319-24574-4_88
- Morgan, V. L., R. J. Roselli, and C. H. Lorenz. Normal three-dimensional pulmonary artery flow determined by phase contrast magnetic resonance imaging. Ann. Biomed. Eng. 26(4):557–566, 1998. · doi:10.1114/1.125
- Perktold, K., M. Hofer, G. Karner, W. Trubel, and H. Schima. Computer simulation of vascular fluid dynamics and mass transport: optimal design of arterial bypass anastomoses. Proc. ECCOMAS 98:484–489, 1998.
- Schiavazzi, D. E., E. O. Kung, A. L. Marsden, C. Baker, G. Pennati, T.-Y. Hsia, A. Hlavacek, A. L. Dorfman and Modeling of Congenital Hearts Alliance (MOCHA) Investigators et al. Hemodynamic effects of left pulmonary artery stenosis after superior cavopulmonary connection: a patient-specific multiscale modeling study. J. Thorac. Cardiovasc. Surg. 149(3):689–696, 2015. · doi:10.1016/j.jtcvs.2014.12.040
- Suh, G. Y., A. S. Les, A. S. Tenforde, S. C. Shadden, R. L. Spilker, J. J. Yeung, C. P. Cheng, R. J. Herfkens, R. L. Dalman, and C. A. Taylor. Quantification of particle residence time in abdominal aortic aneurysms using magnetic resonance imaging and computational fluid dynamics. Ann. Biomed. Eng. 39:864–883, 2011. · doi:10.1007/s10439-010-0202-4
- Tang, B. T., S. S. Pickard, F. P. Chan, P. S. Tsao, C. A. Taylor, and J. A. Feinstein. Wall shear stress is decreased in the pulmonary arteries of patients with pulmonary arterial hypertension: an image-based, computational fluid dynamics study. Pulm. Circ. 2(4):470–476, 2012. · doi:10.4103/2045-8932.105035
- Updegrove, A., N. M. Wilson, and S. C. Shadden. Boolean and smoothing of discrete polygonal surfaces. Adv. Eng. Softw. 95:16–27, 2016. · doi:10.1016/j.advengsoft.2016.01.015
- Wang K. C.Y. Level set methods for computational prototyping with application to hemodynamic modeling. PhD thesis, Stanford University, 2001.
- Zhou, M., O. Sahni, H. J. Kim, C. A. Figueroa, C. A. Taylor, M. S. Shephard, and K. E. Jansen. Cardiovascular flow simulation at extreme scale. Comput. Mech., 46(1):71–82, 2010. · doi:10.1007/s00466-009-0450-z
Cited by
Kupfer, M. E., Lin, W.-H., Ravikumar, V., Qiu, K., Wang, L., Gao, L., Bhuiyan, D. B., Lenz, M., Ai, J., Mahutga, R. R., et al. (2020) · Circulation Research · doi:10.1161/circresaha.119.316155 · Cited by 329
Kadem, M., Garber, L., Abdelkhalek, M., Al-Khazraji, B. K., & Keshavarz-Motamed, Z. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2022.3142058 · Cited by 89
Uncertainty quantification of simulated biomechanical stimuli in coronary artery bypass grafts
Tran, J. S., Schiavazzi, D. E., Kahn, A. M., & Marsden, A. L. (2019) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2018.10.024 · Cited by 37
A Hybrid Experimental-Computational Modeling Framework for Cardiovascular Device Testing
Kung, E., Farahmand, M., & Gupta, A. (2019) · Journal of Biomechanical Engineering · doi:10.1115/1.4042665 · Cited by 28
Gao, H., Zhu, X., & Wang, J.-X. (2020) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2020.113047 · Cited by 27
Metadata
- Authors
- Updegrove, A., Wilson, N. M., Merkow, J., Lan, H., Marsden, A. L., & Shadden, S. C.
- Venue
- Annals of Biomedical Engineering
- Published
- 2016-12-08
- Volume
- 45
- Issue
- 3
- Pages
- 525-541
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2560585316
- Cited by
- 651
- References
- 56
- FWCI
- 11.40
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Funders
- Office of Cyberinfrastructure (1407834, 1562450)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SimVascular: An Open Source Pipeline for Cardiovascular Simulation. https://app.cochat.ai/papers/10.1007/s10439-016-1762-8
- The paper
- Updegrove, A., Wilson, N. M., Merkow, J., Lan, H., Marsden, A. L., & Shadden, S. C. (2017). SimVascular: An Open Source Pipeline for Cardiovascular Simulation. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-016-1762-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.