Tubular Heart Valves from Decellularized Engineered Tissue
Open accessThe DOI matches its Crossref record.
Abstract
A novel tissue-engineered heart valve (TEHV) was fabricated from a decellularized tissue tube mounted on a frame with three struts, which upon back-pressure cause the tube to collapse into three coapting “leaflets.” The tissue was completely biological, fabricated from ovine fibroblasts dispersed within a fibrin gel, compacted into a circumferentially aligned tube on a mandrel, and matured using a bioreactor system that applied cyclic distension. Following decellularization, the resulting tissue possessed tensile mechanical properties, mechanical anisotropy, and collagen content that were comparable to native pulmonary valve leaflets. When mounted on a custom frame and tested within a pulse duplicator system, the tubular TEHV displayed excellent function under both aortic and pulmonary conditions, with minimal regurgitant fractions and transvalvular pressure gradients at peak systole, as well as well as effective orifice areas exceeding those of current commercially available valve replacements. Short-term fatigue testing of one million cycles with pulmonary pressure gradients was conducted without significant change in mechanical properties and no observable macroscopic tissue deterioration. This study presents an attractive potential alternative to current tissue valve replacements due to its avoidance of chemical fixation and utilization of a tissue conducive to recellularization by host cell infiltration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cell-derived matrices for tissue engineering and regenerative medicine applications
Fitzpatrick, L. E., & McDevitt, T. C. (2015) · Biomaterials Science · doi:10.1039/c4bm00246f · Cited by 211
The host response to naturally-derived extracellular matrix biomaterials
Morris, A. H., Stamer, D. K., & Kyriakides, T. R. (2017) · Seminars in Immunology · doi:10.1016/j.smim.2017.01.002 · Cited by 180
Recellularization of decellularized heart valves: Progress toward the tissue-engineered heart valve
VeDepo, M. C., Detamore, M. S., Hopkins, R. A., & Converse, G. L. (2017) · Journal of Tissue Engineering · doi:10.1177/2041731417726327 · Cited by 117
Farag, A., Hashimi, S. M., Vaquette, C., Volpato, F. Z., Hutmacher, D. W., & Ivanovski, S. (2018) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2018.01.014 · Cited by 38
Metadata
- Authors
- Syedain, Z. H., Meier, L. A., Reimer, J. M., & Tranquillo, R. T.
- Venue
- Annals of Biomedical Engineering
- Published
- 2013-07-30
- Volume
- 41
- Issue
- 12
- Pages
- 2645-2654
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2088979464
- Cited by
- 61
- References
- 0
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tubular Heart Valves from Decellularized Engineered Tissue. https://app.cochat.ai/papers/10.1007/s10439-013-0872-9
- The paper
- Syedain, Z. H., Meier, L. A., Reimer, J. M., & Tranquillo, R. T. (2013). Tubular Heart Valves from Decellularized Engineered Tissue. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-013-0872-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.