Real-Time Electronic Adherence Monitoring is Feasible, Comparable to Unannounced Pill Counts, and Acceptable
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Second generation electronic medication adherence monitors provide real-time data on pill bottle opening behavior. Feasibility, validity, and acceptability, however, have not been established. Med-eMonitor is a multi-compartment adherence device with reminder and education capacity that transmits data through a telephone connection. Monthly adherence levels were measured for 52 participants over approximately 3 months using the Med-eMonitor (unadjusted and adjusted for participant confirmed dosing) and unannounced pill counts. HIV RNA was assessed before and after the 3-month period. Acceptability of Med-eMonitor was determined. Over 92% of Med-eMonitor data was transmitted daily. Unannounced pill counts significantly correlated with adjusted Med-eMonitor adherence (r = 0.29, P = 0.04). HIV RNA significantly correlated with unannounced pill counts (r = −0.34, P = 0.02), and trended toward a significant correlation with unadjusted Med-eMonitor adherence (r = −0.26; P = 0.07). Most, but not all, participants liked using the Med-eMonitor. Med-eMonitor allows for real-time adherence monitoring and potentially intervention, which may be critical for prolonging treatment success.ResumenLa segunda generación de monitores electrónicos de adherencia a la medicación proporcionan datos en tiempo real sobre el comportamiento de la apertura de la píldora botella. Viabilidad, validez y aceptación, sin embargo, no se han establecido. Med-eMonitor es un dispositivo de la adhesión de varios compartimentos con capacidad de recordatorio y la educación que transmite datos a través de una conexión telefónica. Los niveles de cumplimiento mensual se realizaron mediciones de 52 participantes para aproximadamente tres meses con el Med-eMonitor (no ajustados y ajustados para que el participante confirmado de dosificación) y píldora no anunciadas recuentos. ARN del VIH se evaluó antes y después del período de tres meses. La aceptabilidad de Med-eMonitor se determinó. Más del 92% de los datos de Med-eMonitor se transmitió diariamente. Píldora no anunciadas recuentos correlacionó significativamente con la adhesión ajustado Med-eMonitor (r = 0,29, P = 0,04). ARN del VIH se correlacionó significativamente con la píldora no anunciadas recuentos (r = −0.34, P = 0,02), y una tendencia hacia una correlación significativa con la adhesión sin ajustar Med-eMonitor ARN (r = −0,26, P = 0,07). La mayoría, pero no todos, los participantes le gustaba usar el Med-eMonitor. Med-eMonitor permite supervisar el cumplimiento en tiempo real y potencial de intervención, que puede ser crítico para prolongar el éxito del tratamiento.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Technology Acceptance Model: Its past and its future in health care
Holden, R. J., & Karsh, B.-T. (2010) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2009.07.002 · Cited by 2,669
(2006) · Globalization and Health · doi:10.1186/1744-8603-2-9 · Cited by 467
Optimal recall period and response task for self-reported HIV medication adherence
Lu, M., Safren, S. A., Skolnik, P. R., Rogers, W. H., Coady, W., Hardy, H., & Wilson, I. B. (2008) · AIDS and Behavior · doi:10.1007/s10461-007-9261-4 · Cited by 361 · cited 1×
“Patient interview is imprecise [5], pharmacy refill reflects maximum possible adherence [6], unannounced pill counts are expensive and labor-intensive [2], and electronic monitoring precludes the use of pill box organizers, which are effective, simple, and inexpensive adherence support tools [7].”
Pilot study of a Web-based compliance monitoring device for patients with congestive heart failure
Artinian, N. T., Harden, J. K., Kronenberg, M. W., Vander Wal, J. S., Daher, E., Stephens, Q., & Bazzi, R. I. (2003) · Heart & Lung · doi:10.1016/s0147-9563(03)00026-8 · Cited by 139
Cited by
Scaling Up mHealth: Where Is the Evidence?
Tomlinson, M., Rotheram-Borus, M. J., Swartz, L., & Tsai, A. C. (2013) · PLoS Medicine · doi:10.1371/journal.pmed.1001382 · Cited by 673
“Interventions categorized under the rubric ‘‘mobile health’’ or ‘‘mHealth’’— broadly defined as medical and public health practice supported by mobile devices [2]—span a variety of applications ranging from the use of mobile phones to improve point of service data collection [3], care delivery [4], and patient communi…”
BackgroundVervloet, M., Linn, A. J., van Weert, J. C. M., de Bakker, D. H., Bouvy, M. L., & van Dijk, L. (2012) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000748 · Cited by 455
Assessing medication adherence: options to consider
Lehmann, A., Aslani, P., Ahmed, R., Celio, J., Gauchet, A., Bedouch, P., Bugnon, O., Allenet, B., & Schneider, M. P. (2014) · International Journal of Clinical Pharmacy · doi:10.1007/s11096-013-9865-x · Cited by 318
Lankowski, A. J., Siedner, M. J., Bangsberg, D. R., & Tsai, A. C. (2014) · AIDS and Behavior · doi:10.1007/s10461-014-0729-8 · Cited by 260
Self-citationVervloet, M., van Dijk, L., Santen-Reestman, J., van Vlijmen, B., van Wingerden, P., Bouvy, M. L., & de Bakker, D. H. (2012) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2012.05.005 · Cited by 215
Goldstein, C. M., Gathright, E. C., & Garcia, S. (2017) · Patient Preference and Adherence · doi:10.2147/ppa.s127277 · Cited by 138
“However, although it may seem counterintuitive that CVD patients, and particularly older patients, can handle electronic monitoring, feasibility studies suggest they can.(69) Health care professionals may also find that interventions using phone counseling or nurses as case managers in primary care may also be effecti…”
Investigating usability of mobile health applications in Bangladesh
Islam, M. N., Karim, M. M., Inan, T. T., & Islam, A. K. M. N. (2020) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-020-1033-3 · Cited by 101
“ications include the use of mobile devices to improve the process of medical data collection [4], service delivery [5], patient-doctor communication [6], and realtime monitoring and adherence support [7]. The mHealth applications have even been widely used in the remote villages of developing countries [8]. For exampl…”
MethodGoldstein, C. M., Gathright, E. C., Dolansky, M. A., Gunstad, J., Sterns, A., Redle, J. D., Josephson, R., & Hughes, J. W. (2014) · Journal of Telemedicine and Telecare · doi:10.1177/1357633x14541039 · Cited by 86
“Haberer et al.(18)), although participants were willing to use the devices, some of them found the reminding features of the telehealth medication containers annoying.”
BackgroundOptimizing Network Connectivity for Mobile Health Technologies in sub-Saharan Africa
Siedner, M. J., Lankowski, A., Musinga, D., Jackson, J., Muzoora, C., Hunt, P. W., Martin, J. N., Bangsberg, D. R., & Haberer, J. E. (2012) · PLoS ONE · doi:10.1371/journal.pone.0045643 · Cited by 36
Self-citationCurrent Trends in Electronic Medication Reminders for Self Care
Fang Kerry, Y., Maeder Anthony, J., & Heidi, B. (2016) · Studies in Health Technology and Informatics · doi:10.3233/978-1-61499-712-2-31 · Cited by 19
Desirability and feasibility of wireless electronic monitoring of medications in clinical trials
Robiner, W. N., Flaherty, N., Fossum, T. A., & Nevins, T. E. (2015) · Translational Behavioral Medicine · doi:10.1007/s13142-015-0316-1 · Cited by 16
User-centered design of an air quality feedback technology to promote adoption of clean cookstoves
Iribagiza, C., Sharpe, T., Wilson, D., & Thomas, E. A. (2020) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-020-0250-2 · Cited by 14
Metadata
- Authors
- Haberer, J. E., Robbins, G. K., Ybarra, M., Monk, A., Ragland, K., Weiser, S. D., Johnson, M. O., & Bangsberg, D. R.
- Venue
- AIDS and Behavior
- Published
- 2011-03-30
- Volume
- 16
- Issue
- 2
- Pages
- 375-382
- ISSN
- 1090-7165 (ISSN-L)
- 1573-3254
- OpenAlex
- W2079164790
- Cited by
- 83
- References
- 4
- FWCI
- 5.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.