Micro-electroporation of mesenchymal stem cells with alternating electrical current pulses
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Various microchannel-based gene electrotransfer methods have been reported [21–34]. The smaller dimensions of microchannels and electrodes enable flow-through processing and create more intense electric fields with lower applied voltages.”
From Gene electrotransfer with flow-through microchannel and lower alternating voltage generated induced pluripotent cells from human lymphoblastoid cell lines (2025) · cites this paper as [23]
In the citing paper
“A common technique in microchannel electroporation relies on constrictions within the channel path [21,23,24,26,28].”
From Gene electrotransfer with flow-through microchannel and lower alternating voltage generated induced pluripotent cells from human lymphoblastoid cell lines (2025) · cites this paper as [23]
In the citing paper
“In this design, the channel contains a wide section and a constricted region, with electrodes positioned at the start and end.”
From Gene electrotransfer with flow-through microchannel and lower alternating voltage generated induced pluripotent cells from human lymphoblastoid cell lines (2025) · cites this paper as [23]
In the citing paper
“Second, the need for a specific processing medium: only low-conductivity media can be used to reduce current, avoiding problems such as bubbling at the electrodes, temperature rise, and pH fluctuations.”
From Gene electrotransfer with flow-through microchannel and lower alternating voltage generated induced pluripotent cells from human lymphoblastoid cell lines (2025) · cites this paper as [23]
In the citing paper
“The electric field lines concentrate at the constriction, creating an intense electric field.”
From Gene electrotransfer with flow-through microchannel and lower alternating voltage generated induced pluripotent cells from human lymphoblastoid cell lines (2025) · cites this paper as [23]
5 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 33
- H. Aslan, Y. Zilberman, L. Kandel, M. Liebergall, R.J. Oskouian, D. Gazit, Z. Gazit, Osteogenic differentiation of noncultured immunoisolated bone marrow-derived CD105+ cells Stem Cells 24(7), 1728–1737 (2006) · DOI · Paper page
- E. Burgermeister, A. Schnoebelen, A. Flament, J. Benz, M. Stihle, B. Gsell, A. Rufer, A. Ruf, B. Kuhn, H.P. Märki, J. Mizrahi, E. Sebokova, E. Niesor, M. Meyer, A novel partial agonist of peroxisome proliferator-activated receptor-gamma (PPARgamma) recruits PPARgamma-coactivator-1alpha, prevents triglyceride accumulation, and potentiates insulin signaling in vitro Mol. Endocrinol 20(4), 809–830 (2006) · DOI · Paper page
- A.I. Caplan, S.P. Bruder, Mesenchymal stem cells: building blocks for molecular medicine in the 21st century Trends Mol. Med. 7, 259–264 (2001) · DOI · Paper page
- G.W. Fuller, Report on the Investigations into the Purification of the Ohio River Water at Louisville Kentucky (D. Van Nostrand Company, New York, 1898)
- Y. Gafni, G. Turgeman, M. Liebergal, G. Pelled, Z. Gazit, D. Gazit, Stem cells as vehicles for orthopedic gene therapy Gene Ther 11(4), 417–426 (2004) · DOI
- D. Gazit, G. Turgeman, P. Kelley, E. Wang, M. Jalenak, Y. Zilberman, I. Moutsatsos, Engineered pluripotent mesenchymal cells integrate and differentiate in regenerating bone: a novel cell-mediated gene therapy J. Gene Med 1(2), 121–133 (1999) · doi:10.1002/(sici)1521-2254(199903/04)1:2<121::aid-jgm26>3.0.co;2-j
- A. Hoffmann, S. Czichos, C. Kaps, D. Bächner, H. Mayer, B.G. Kurkalli, Y. Zilberman, G. Turgeman, G. Pelled, G. Gross, D. Gazit, The T-box transcription factor Brachyury mediates cartilage development in mesenchymal stem cell line C3H10T1/2 J. Cell Sci 115(4), 769–781 (2002) · DOI
- A. Hoffmann, G. Pelled, G. Turgeman, P. Eberle, Y. Zilberman, H. Shinar, K. Keinan-Adamsky, A. Winkel, S. Shahab, G. Navon, G. Gross, D. Gazit, Neotendon formation induced by manipulation of the Smad8 signalling pathway in mesenchymal stem cells J. Clin. Invest 116(4), 940–952 (2006) · DOI · Paper page
- Y. Huang, B. Rubinsky, Micro-electroporation: improving the efficiency and understanding of electrical permeabilization of cells Biomed. Microdev 3, 145–150 (1999) · DOI
- Y. Huang, B. Rubinsky, Microfabricated electroporation chip for single cell membrane permeabilization Sens. Actuators A 89, 242–249 (2001) · DOI
- Y. Huang, B. Rubinsky, Flow-Through Micro-Electroporation Chip for Genetic Engineering of Individual Cells. Hilton Head, South Carolina: s.n., 2002. Proceedings of International Solid-State Sensor, Actuator, and Microsystems Workshop. pp. 198–201 · doi:10.31438/trf.hh2002.50
- Y. Huang, N. Sekhon, J. Borninski, N. Chen, B. Rubinsky, Instantaneous, quantitative single-cell viability assessment by electrical evaluation of cell membrane integrity with microfabricated devices Sens. Actuators A 105, 31–39 (2003) · DOI
- M. Khine, A. Lau, C. Ionescu-Zanetti, J. Seo, L.P. Lee, A single cell electroporation chip Lab Chip 5, 38–43 (2004) · doi:10.1039/b408352k
- N. Kimelman, G. Pelled, G.A. Helm, J. Huard, E.M. Schwarz, D. Gazit, Review: gene- and stem cell-based therapeutics for bone regeneration and repair Tissue Eng 13(6), 1135–1150 (2007) · DOI
- L.M. Mir, M. Belehdradek, C. Domenge, S. Orlowski, J. Poddevin Jr., G. Schwab, B. Luboinnski, C. Paoletti, Electrochemotherapy, a new antitumor treatment: first clinical trial C. R. Acad. Sci. III Sci. Vie. 313, 613–618 (1991)
- I.K. Moutsatsos, G. Turgeman, S. Zhou, B.G. Kurkalli, G. Pelled, L. Tzur, P. Kelley, N. Stumm, S. Mi, R. Müller, Y. Zilberman, D. Gazit, Exogenously regulated stem cell-mediated gene therapy for bone regeneration Mol. Ther 3(4), 449–461 (2001) · DOI · Paper page
- E. Neumann, K. Rosenheck, Permeability changes induced by electric impulses in vesicular membranes J. Membr. Biol 29(10), 279–290 (1972) · DOI · Paper page
- E. Neumann, M. Schaefer-Ridder, Y. Wang, P.H. Hofschneider, Gene transfer into mouse lyoma cells by electroporation in high electrical fields EMBO J 1(7), 841–845 (1982) · DOI · Paper page
- E. Neumann, A. Sprafke, H. Boldt, H. Wolf, in Biophysical considerations of membrane electroporation, ed. by D.C. Chassy, B.M. Saunders, J.A. Sowers, A.E. Chang. Guide to Electroporation and Electrofusion (Academic, San Diegeo, 1992), pp. 77–90[book auth.]
- M.F. Pittenger, A.M. Mackay, S.C. Beck, R.K. Jaiswal, R. Douglas, J.D. Mosca, M.A. Moorman, D.W. Simonetti, S. Craig, D.R. Marshak, Multilineage potential of adult human mesenchymal stem cells Science 284(5411), 143–147 (1999) · DOI · Paper page
- B. Rubinsky, G. Onik, P. Mikus, Irreversible electroporation: a new ablation modality—clinical implications Technol. Cancer Res. Treat. 6(1), 37–48 (2007) · DOI · Paper page
- A.J.H. Sale, W.A. Hamilton, Effects of high electric fields on microorganisms. I. Killing of bacteria and yeasts Biochim. Biophys. Acta 148, 781–788 (1967) · DOI · Paper page
- A.J.H. Sale, W.A. Hamilton, Effects of high electric fields on micro-organisms III. Lysis of erythrocytes and protoplasts Biochim. Biophys. Acta 163, 37–43 (1968) · DOI · Paper page
- R. Stämpfli, Reversible electrical breakdown of the excitable membrane of a Ranvier node An. Acad. Bras. Cienc. 30, 57–63 (1957)
- J. Teissie, T.Y. Tsong, Voltage modulation of Na/K transport in human eythrocytes J. Physiol. (Paris) 77, 1043–1053 (1981)
- G. Tresset, C. Iliescu, Electrcal control of loadaed biomimetic femtoliter vesicles in microfluidic systems Appl. Phys. Lett. 90, 173901–173904 (2007) · doi:10.1063/1.2731517
- T.Y. Tsong, On electroporation of cell-membranes and some related phenomena Bioelectrochem. Bioenerg. 24(3), 271–295 (1990) · DOI · Paper page
- H.Y. Wang, A.K. Bhunia, C. Lu, A microfluidic flow-through device for high throughput electrical lysis of bacterial cells based on continuous dc voltage Biosens. Bioelectron. 22, 582–588 (2006) · DOI
- J. Weaver, Y.A. Chizmadzhev, Theory of electroporation: a review Bioelectrochem. Biophys. Acta 41, 135–160 (2005)
- J. Wegener, C.R. Keese, I. Giaver, Recovery of adherent cells afer in situ electroporation monitored electrically Biotechniques 33(2), 348–354 (2002) · DOI
- T.D. Xie, T.Y. Tsong, Study of mechanisms of electrical field-induced DNA transfection II Biophys. J. 58, 897–903 (1990) · DOI
- U. Zimmermann, Electric field-mediated fusion and related electrical phenomena Biochim. Biophys. Acta 694(3), 227–277 (1982) · DOI · Paper page
- U. Zimmermann, G. Pilwat, F. Riemann, Dielectric breakdown of cell membranes Biophys. J. 14(11), 881–899 (1974) · DOI · Paper page
Cited by
Ishii-Teshima, M., Maeda, K., Hanauchi, K., Asechi, E., Setyawan, D., Niki, T., Nakashima, K., Kurita, H., Numano, R., & Shibata, T. (2025) · PLOS One · doi:10.1371/journal.pone.0333491 · Cited by 4
Metadata
- Authors
- Ziv, R., Steinhardt, Y., Pelled, G., Gazit, D., & Rubinsky, B.
- Venue
- Biomedical Microdevices
- Published
- 2008-09-25
- Volume
- 11
- Issue
- 1
- Pages
- 95-101
- ISSN
- 1387-2176
- 1572-8781
- Cited by
- 67
- References
- 0
- Language
- en
- Licence
- www.springer.com/tdm (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Micro-electroporation of mesenchymal stem cells with alternating electrical current pulses. https://app.cochat.ai/papers/10.1007/s10544-008-9213-4
- The paper
- Ziv, R., Steinhardt, Y., Pelled, G., Gazit, D., & Rubinsky, B. (2009). Micro-electroporation of mesenchymal stem cells with alternating electrical current pulses. Biomedical Microdevices. https://doi.org/10.1007/s10544-008-9213-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.