Reliable long-term cell culture in microfluidic system is limited by air bubble formation and accumulation. In this study, we developed a bubble removal system capable of both trapping and discharging air bubbles in a consistent and reliable manner. Combined with PDMS (Polydimethylsiloxane) hydrophilic surface treatment and vacuum filling, a microfluidic perifusion system equipped with the bubble trap was successfully applied for long-term culture of mouse pancreatic islets with no bubble formation and no flow interruption. In addition to demonstrating normal cell viability and islet morphology, post-cultured islets exhibited normal insulin secretion kinetics, intracellular calcium signaling, and changes in mitochondrial potentials in response to glucose challenge. This design could be easily adapted by other microfluidic systems due to its simple design, ease of fabrication, and portability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s10544-011-9618-3

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Leak tightness and absence of bubbles are the main failure causes of microfluidic systems.

    “Particular care should be given to the leak tightness and the absence of bubbles since these are the main failure causes of microfluidic systems (Leung et al., 2022; Wang et al., 2012).”

    From Recommendations on fit-for-purpose criteria to establish quality management for microphysiological systems and for monitoring their reproducibility (2024) · cites this paper as Wang et al., 2012

    The Introduction calls bubble formation and accumulation a critical obstacle in microfluidic applications and says bubbles can impair device performance. It does not identify leaks as a failure cause or establish that leaks and bubbles together are the main causes of microfluidic-system failure. (LLM, conf=0.87)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Metadata

Authors
Wang, Y., Lee, D., Zhang, L., Jeon, H., Mendoza-Elias, J. E., Harvat, T. A., Hassan, S. Z., Zhou, A., Eddington, D. T., & Oberholzer, J.
Affiliations
University of Illinois Chicago (US)
Corresponding author
Oberholzer, José
Venue
Biomedical Microdevices
Published
2012-01-18
Volume
14
Issue
2
Pages
419-426
ISSN
  • 1387-2176 (ISSN-L)
  • 1572-8781
OpenAlex
W1986681896
Cited by
63
References
21
Citations by year
2024: 11 · 2023: 8 · 2022: 6 · 2021: 9 · 2020: 8 · 2019: 5 · 2018: 2 · 2017: 4 · 2016: 4 · 2015: 2 · 2014: 2 · 2013: 1 · 2012: 1
FWCI
1.96
Type
journal article
Language
en
Open access
Locations
  • Biomedical Microdevices (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • University of Illinois at Chicago
  • National Institute of Diabetes and Digestive and Kidney Diseases (R01DK091526)
  • National Center for Research Resources (U42RR023245)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
Keywords
air bubble removal, bubble trapping, bubble accumulation, long-term cell culture, pancreatic islets, vacuum filling, insulin secretion, intracellular calcium signaling, mitochondrial membrane potential, glycemic response
MeSH terms
Insulin Secretion, Animals, Cell Survival, Dimethylpolysiloxanes, Equipment Design, Glucose, Insulin, Islets of Langerhans, Mice, Inbred C57BL, Cell Culture Techniques, Microfluidics, Microfluidic Analytical Techniques, Mice

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review