Microfluidic gut-on-a-chip with three-dimensional villi structure
The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Current in vitro gut models lack physiological relevance, and various approaches have been taken to improve current cell culture models. For example, mimicking the three-dimensional (3D) tissue structure or fluidic environment has been shown to improve the physiological function of gut cells. Here, we incorporated a collagen scaffold that mimics the human intestinal villi into a microfluidic device, thus providing cells with both 3D tissue structure and fluidic shear. We hypothesized that the combined effect of 3D structure and fluidic shear may provide cells with adequate stimulus to induce further differentiation and improve physiological relevance. The physiological function of our '3D gut chip' was assessed by measuring the absorptive permeability of the gut epithelium and activity of representative enzymes, as well as morphological evaluation. Our results suggest that the combination of fluidic stimulus and 3D structure induces further improvement in gut functions. Our work provides insight into the effect of different tissue environment on gut cells.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Culturing human Caco-2 intestinal epithelial cells on these crenulated surfaces was shown to promote formation of a similarly crenulated epithelium, and this was accompanied by increased absorption of drug compounds and improved cellular metabolic enzyme cytochrome P-450 activity in response to apical fluid shear stress.39”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [39]
In the citing paper
“However, this design did not enable analysis of intestinal barrier function because the solid polymer material blocked the abluminal surface of the epithelium.”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [39]
Citations
Cites
Lodish, H. F. (1986) · Cited by 5,650
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Stem Cells, Self-Renewal, and Differentiation in the Intestinal Epithelium
van der Flier, L. G., & Clevers, H. (2009) · Annual Review of Physiology · doi:10.1146/annurev.physiol.010908.163145 · Cited by 1,871 · cited 1×
“For example, the gut environment is a complex and dynamic combination of various factors, such as various cell types (van der Flier and Clevers 2009), complex tissue architecture (Lodish 2000), presence of microbiota (Quigley 2013), and peristaltic movement (Huizinga and Lammers 2009).”
BackgroundArtursson, P., Palm, K., & Luthman, K. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00128-9 · Cited by 1,543
Principles of Anatomy and Physiology
Baker, G. F., Tortora, G. J., & Nostakos, N. P. A. (1976) · The American Journal of Nursing · doi:10.2307/3423898 · Cited by 1,312
(1987) · Comparative Biochemistry and Physiology Part A: Physiology · doi:10.1016/0300-9629(87)90455-5 · Cited by 1,122
Bile acid signaling in metabolic disease and drug therapy
Li, T., & Chiang, J. Y. L. (2014) · Pharmacological Reviews · doi:10.1124/pr.113.008201 · Cited by 935 · cited 1×
“The main sites where absorption and metabolism occur are the intestine and the liver, respectively, which are complex processes with inter-organ signaling (Bieghs and Trautwein 2014; Li and Chiang 2014).”
BackgroundIn vitro microvessels for the study of angiogenesis and thrombosis
Zheng, Y., Chen, J., Craven, M., Choi, N. W., Totorica, S., Diaz-Santana, A., Kermani, P., Hempstead, B., Fischbach-Teschl, C., López, J. A., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201240109 · Cited by 894
Engineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Gut-on-a-Chip microenvironment induces human intestinal cells to undergo villus differentiation
Kim, H. J., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40126j · Cited by 750 · cited 7×
“Known as intestinal villi, these structures are believed to aid in increasing the absorptive surface area, and involved in differentiation of gut epithelial cells (Rao and Wang 2010; Kim and Ingber 2013).”
BackgroundResultInfluential
Research works printed but not linked: 6
- V. Bieghs, C. Trautwein, Hepatobiliary Surg Nutr. 3(6), 377–385 (2014)
- M. Chi, B. Yi, S. Oh, D.J. Park, J.H. Sung, S. Park, Biomed. Microdevices 17(3), 9966 (2015)
- S.H. Kim, M. Chi, B. Yi, S.H. Kim, S. Oh, Y. Kim, S. Park, J.H. Sung, Integr Biol (Camb) 6(6), 1222–1232 (2014)
- E.M. Quigley, Gastroenterol Hepatol (NY) 9(9), 560–569 (2013)
- B.R. Ware, S.R. Khetani, Trends Biotechnol. 8(30), 19343–19352 (2016)
- R. Yumoto, T. Murakami, M. Sanemasa, R. Nasu, J. Nagai, M. Takano, Drug Metab. Dispos. 29(2), 145–151 (2001)
Cited by
Items 201–228 of 228
IPSC-derived intestinal organoids and current 3D intestinal scaffolds
Malijauskaite, S., Mulvihill, J. J., Grabrucker, A. M., & McGourty, K. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823809-7.00011-6 · Cited by 1
On chip complex breast tumour microenvironment: application to research in nanomedicine
Blondé, J.-B. (2020) · doi:10.3990/1.9789036550598 · Cited by 1
Development of a dual flow microfluidic device for the study of barrier systems
Baldwin, L. (2020) · Repository@Hull (Worktribe) (University of Hull) · Cited by 2
Wang, Z., Zhao, Y. C., Zhao, H., Nasser, A., Yap, N. A., Liu, Y., Sun, A., Chen, W., Butcher, K. S., Ang, T., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.03.03.709446 · Cited by 1
Das, P. (2018) · theses.fr (ABES) · doi:10.3990/1.159058878
Development of a Liver-Gut device for the Evaluation of Drug Bioavailability
Iwao, T., & Matsunaga, T. (2019) · Drug Delivery System · doi:10.2745/dds.34.249
3D intestinal models towards a more realistic permeability screening
Almeida, A., Azevedo, C., Macedo, M. H., & Sarmento, B. F. C. C. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818038-9.00003-x · Cited by 5
Future Perspectives for Gel-Inks for 3D Printing in Tissue Engineering
Kumar, A., Thakur, V. K., & Voicu, Ș. I. (2021) · Gels horizons: from science to smart materials · doi:10.1007/978-981-16-4667-6_12 · Cited by 2
Tube-Shaped In-Vitro Intestinal Gut Model with 3D Isotropic Medium Supply for Bacterial Symbiosis
Kawahara, M., Itai, S., & Onoe, H. (2022) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems51670.2022.9699523
The artificial gut : integrating in vitro models of the human digestive tract with mass spectrometry
Santbergen, M. J. C. (2020) · doi:10.18174/532696
Next-generation Bioactive Delivery Systems
McClements, D. J. (2023) · Royal Society of Chemistry eBooks · doi:10.1039/bk9781839165566-00477 · Cited by 1
Organ-on-chip models for intestinal permeability studies
Carvalho, A. M., & Sarmento, B. F. C. C. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15510-9.00011-6
Role of Microfluidics in Drug Encapsulation for Point-of-care Diagnosis and Prognosis
Mishra, S., Harikrishnan, S., Perwez, A., Wahabi, K., Dahiya, U. R., & Bano, S. (2024) · Royal Society of Chemistry eBooks · doi:10.1039/9781837673476-00190
Rojas-Garcia, D., Hamel, D., Foncy, J., Sambe, D., Pefaure, S., Malaquin, L., & Ferrand, A. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.04.10.648106
“…Shim et al . cultured Caco-2 cells on a PDMS chip containing a collagen scaffold with 3D villi supported on a porous membrane, showing an increased activity of one of the drug metabolism enzymes, cytochrome P450 3A4, when the cells were cultured in 3D under flow compared to 2D cultures [22].”
mSphere of Influence: Adapting new models for studying Toxoplasma gondii gut interactions
Ramírez‐Flores, C. J. (2025) · mSphere · doi:10.1128/msphere.00211-25
Development of an in-vitro intestinal model featuring peristaltic motion
Gérémie, L. (2019) · theses.fr (ABES) · doi:10.70675/c3a13b73z70d7z4143zbb1eza871bcd89028
A 3D gut on chip to study the peristalsis influence on the physiopathological cellular ecosystem
Bernheim-Dennery, M. (2023) · theses.fr (ABES) · doi:10.70675/c4cc4f3ez501az4b2cz9b30z74012622987e
Scalable microfluidic blood oxygenator with compliant membrane for improved performance
Calzuola, S. T. (2024) · theses.fr (ABES) · doi:10.70675/ba5166b4ze915z4b43zb98fz2b278bb6ee65
Zavagna, L., Casanova, M. R., Pierantoni, L., Carvalho, M. R., Silva‐Correia, J., Macchi, T., Troisi, F., Giovannoni, R., Reis, R. L., Danti, S., et al. (2026) · Materials Today Bio · doi:10.1016/j.mtbio.2026.103134
“In engineered intestinal models, epithelial barrier integrity is frequently evaluated using functional readouts such as TEER or permeability assays, particularly in gut-on-chip platforms incorporating porous membranes or integrated electrodes [11,29,34].”
Lee, S. Y., Yoo, S. J., & Sung, J. H. (2026) · BioChip Journal · doi:10.1007/s13206-026-00267-w
“…the reason for the higher TEER value in the chip than the wells is because the fluid flow in the chip positively stimulated intestinal cell differ - entiation, which is consistent with our previous studies that mechanical stimulation by the fluid flow in the chip caused barrier strengthening [37].”
Self-citationJang, L. K., Robertson, C., Triplett, M., Hinckley, A., Moya, M. L., Kok, C. R., Mohagheghi, M. V., Weisenberger, T., Bourguet, F. A., Bowers, E. S., et al. (2026) · Biofabrication · doi:10.1088/1758-5090/ae8ccc
“However, these features are often omitted from other platforms due to integration challenges with PDMS microchannels [12, 14, 18].”
InfluentialRojas-Garcia, D., Hamel, D., Foncy, J., Hut, M., Thibault, C., Sambe, D., Pefaure, S., Quaranta, M., Onfroy-Roy, L., Malaquin, L., et al. (2026) · Lab on a Chip · doi:10.1039/d6lc00192k
Pinon, L., Debache, A., Thuaud, A., Tiraboschi, L., Vella, G., Riou-Ramon, J., Cordier, C., Helal, C., Hersen, P., Rescigno, M., et al. (2026) · Communications Biology · doi:10.1038/s42003-026-10675-1
Metadata
- Authors
- Shim, K.-Y., Lee, D., Han, J., Nguyen, N.-T., Park, S., & Sung, J. H.
- Affiliations
- Hongik University (KR)
- Sungkyunkwan University (KR)
- Griffith University (AU)
- Corresponding author
- Park, Sungsu
- Sung, Jong Hwan
- Venue
- Biomedical Microdevices
- Published
- 2017-04-27
- Volume
- 19
- Issue
- 2
- Pages
- 37-37
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2609369954
- Cited by
- 229
- References
- 56
- Citations by year
- 2026: 10 · 2025: 27 · 2024: 26 · 2023: 33 · 2022: 27 · 2021: 35 · 2020: 27 · 2019: 22 · 2018: 20 · 2017: 2
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biomedical Microdevices (publishedVersion)
- PubMed (publishedVersion)
- Griffith Research Online (submittedVersion)
- Funders
- Ministry of Trade, Industry and Energy (MOTIE), Republic of Korea (R0004073)
- National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIP) (2016R1C1B1009747)
- KFRI (Korea Food Research Institute) (E0121705)
- Hongik University (Faculty Research Fund)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- gut-on-a-chip, intestinal villi, collagen scaffolds, intestinal epithelium, enzyme activity, cell differentiation, in vitro gut model, microfluidics
- MeSH terms
- Collagen, Dimethylpolysiloxanes, Humans, Intestinal Mucosa, Intestines, Membranes, Artificial, Permeability, Porosity, Caco-2 Cells, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.